{"product_id":"primary-air-insulated-switchgear-pix-bus-riser-functional-unit-12kv-upto-4000a-upto-40ka-3s-width-1000mm","title":"Primary Air Insulated Switchgear, PIX, bus riser functional unit, 12kV, upto 4000A, upto 40kA 3s, width 1000mm","description":"\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003cbr\u003eMain\u003cbr\u003eMaster range    SeT Series\u003cbr\u003eRange of product    PIX\u003cbr\u003eProduct name    PIX 12\u003cbr\u003eFunctional unit    BR bus riser cubicle\u003cbr\u003eInsulation technology    Air insulated switchgear\u003cbr\u003eNumber of phases    3\u003cbr\u003eNetwork type    AC\u003cbr\u003eType of installation    Indoor\u003cbr\u003eBusbar system    Single busbar\u003cbr\u003eSwitching device    Metering device\u003cbr\u003eDisconnecting device\u003cbr\u003eProduct compatibility    EvoPact MTX\u003cbr\u003eEvoPact UTX\u003cbr\u003eStandards    IEC 62271-200\u003cbr\u003eRated voltage (Ur)    12 kV\u003cbr\u003eRated short-duration power frequency withstand voltage (Ud) \/ Common value    28 kV\u003cbr\u003eRated lightning impulse withstand voltage (Up) \/ Common value    75 kV\u003cbr\u003eRated frequency (fr)    50\/60 Hz\u003cbr\u003eRated continuous current of busbars (Ir)    4000 A\u003cbr\u003eRated continuous current (Ir)    2500 A\u003cbr\u003e3150 A\u003cbr\u003e4000 A\u003cbr\u003eRated short-time withstand current (Ik)    25 kA\u003cbr\u003e31.5 kA\u003cbr\u003e40 kA\u003cbr\u003eRated duration of short-circuit (tk)    3 s\u003cbr\u003eRated peak withstand current (Ip)    100 kA 50 Hz\u003cbr\u003e104 kA 60 Hz\u003cbr\u003eLoss of service continuity category    LSC2B\u003cbr\u003eInternal arc classification    AFLR\u003cbr\u003eRated arc fault current (IA)    40 kA\u003cbr\u003eRated arc fault duration (tA)    1 s\u003cbr\u003eInternal arc gas evacuation    Upwards inside the room\u003cbr\u003eUpwards outside the room\u003cbr\u003ePartition class    PM\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eComplementary\u003c\/strong\u003e\u003cbr\u003eDegrees of protection provided by enclosures (IP code)    IP3X\u003cbr\u003eIP4X\u003cbr\u003eIPX2\u003cbr\u003eIP2X (between compartments)\u003cbr\u003eDegree of protection of enclosure against external mechanical impacts (IK code)    IK07\u003cbr\u003eSensor type    TH110 thermal sensor\u003cbr\u003eCL110 environmental sensor\u003cbr\u003eVoltage presence type    VPIS voltage presence indicating system\u003cbr\u003eVDIS voltage detecting and indicating system\u003cbr\u003eProtection relay    Easergy P3\u003cbr\u003eEasergy P5\u003cbr\u003eEasergy Sepam series 60\u003cbr\u003eEasergy Sepam series 80\u003cbr\u003eArc fault detector    Easergy Vamp 125\u003cbr\u003eMass    1100 kg\u003cbr\u003eHeight    2130 mm (standard)\u003cbr\u003e2690 mm (with deflector)\u003cbr\u003e2730 mm (tunnel with external exhaust)\u003cbr\u003e3180 mm (tunnel with absorber)\u003cbr\u003eWidth    1000 mm\u003cbr\u003eDepth    1405 mm\u003cbr\u003e1605 mm\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003cbr\u003eProduct certifications    BV Marine\u003cbr\u003eDNV-GL Marine\u003cbr\u003eAmbient air temperature for operation    -5…40 °C\u003cbr\u003eAmbient air temperature for storage    -25…55 °C\u003cbr\u003eHumidity conditions    Average relative humidity over 24 h \u0026lt;= 95 %\u003cbr\u003eAverage relative humidity over 1 month \u0026lt;= 90 %\u003cbr\u003eOperating altitude    \u0026lt;= 1000 m\u003c\/p\u003e\n\u003cp\u003eContractual warranty\u003cbr\u003eWarranty (in months)    18\u003cbr\u003e\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":47677912383588,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/3791\/7796\/files\/RNG_60678_main_image_369_7.jpg?v=1768041883","url":"https:\/\/www.jublipower.com\/products\/primary-air-insulated-switchgear-pix-bus-riser-functional-unit-12kv-upto-4000a-upto-40ka-3s-width-1000mm","provider":"Jublipower","version":"1.0","type":"link"}