{"product_id":"powerlogic™-p5v20-24-250v-4vt-10di-8do","title":"PowerLogic™ P5V20 24-250V 4VT 10DI-8DO","description":"\u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003cbr\u003eThe PowerLogic P5 is Schneider Electric's withdrawable protection and control relay for demanding medium voltage distribution applications. This voltage relay offers withdrawable design with backup memory function enabling industry-leading 10 minute recovery time. It provides redundant Ethernet including IEC 61850 as well as plug and play communication modules that can evolve with your application. The product embeds latest cybersecurity functionality to help prevent intentional mis-use and cyber-threats. PowerLogic P5 offers safety, security, and connectivity built on more than 100 years of experience in protection relays. The PowerLogic P5 protection relay can be applied to all types of MV distribution networks. It can be supplied with 24 to 250 VDC and 100 to 230 VAC. It works with conventional VTs. 3 phase voltage inputs, 1 neutral voltage input. It offers 10 digital inputs and 8 digital outputs and no communications. Communication modules can be added any time. The product dimensions are 180 mm in height (7.09 in), 102 mm in width (4.01 in) and 224 mm in depth 8.82 in) for a net weight of 2.5 kg (5.5 lbs). PowerLogic P5 is compliant with EN 60255-26, EN 60255-27 standard and with UL Standard. It provides Marine certification. This product can be flush mounted on the panel orin the rack. Flush mounting frames to ensure IP54 are available. Fixing and wiring accessories are included. Plug and play communication modules: Ethernet RSTP RJ45 (REL51038), Ethernet RSTP FO (REL51039), Ethernet HSR\/PRP FO (REL51033). And also RS485 serial RJ45 (REL51036), RS485 serial FO (REL51040), Extension\/backup memory (REL51034). IP54 flush mounting frame (REL51032), IRIG-B module (REL51045). connection cords (59660, 59661, 59662). eSetup Easergy Pro software with virtual injection testing and EcoStruxure Power Device app for simpler and safer operation and maintenance. Included with functions as per the datasheet below. For other configurations with additional functions and options, Please select via Product Selector.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003cbr\u003eMain\u003cbr\u003eRange of product    PowerLogic P5\u003cbr\u003eProduct or component type    Protection and control relay\u003cbr\u003eRelay application    Voltage\u003cbr\u003eproduct reference    P5V20-AABB-DAAAA-BAEA\u003cbr\u003eMounting case size    20TE\u003cbr\u003eDevice mounting    Flush\u003cbr\u003eMounting mode    Withdrawable\u003cbr\u003epower supply    24...240 V DC\u003cbr\u003e100...230 V AC\u003cbr\u003emeasuring inputs    : VT voltage 4\u003cbr\u003eNumber of sensors    0 temperature sensor(s)\u003cbr\u003e0 arc sensor(s)\u003cbr\u003enumber of Digital Inputs (DI)    10\u003cbr\u003enumber of analogue inputs    0\u003cbr\u003enumber of Digital Outputs (DO)    7 DO\u003cbr\u003e1 watchdog\u003cbr\u003enumber of analogue outputs    0\u003cbr\u003ecommunication ports    USB port 2 front\u003cbr\u003ecommunication protocols    -\u003cbr\u003eCybersecurity    Port hardening\u003cbr\u003eFirmware signature\u003cbr\u003eClient IP address filter\u003cbr\u003eSecured communication with assciated tools\u003cbr\u003eSecurity policy management\u003cbr\u003eRole-based access control\u003cbr\u003eSecurity log\u003cbr\u003eLDAP\u003cbr\u003eRADIUS based user authentication\u003cbr\u003eIEC 62443-4-2 SL1\u003cbr\u003eprotection functions    Overvoltage\u003cbr\u003eUndervoltage\u003cbr\u003ePositive sequence undervoltage 27P\u003cbr\u003eEarth fault overvoltage 59N\u003cbr\u003eUnderfrequency 81\/81N\u003cbr\u003eRate of change of frequency 81R\u003cbr\u003eSynchro-check\u003cbr\u003eBreaker failure 50BF\u003cbr\u003eLockout relay\u003cbr\u003eVT supervision\u003cbr\u003eProgrammable stages\u003cbr\u003eProgrammable curve\u003cbr\u003emeasurement functions    Voltage 3-phase\u003cbr\u003eVoltage residual\u003cbr\u003eVoltage zero sequence\u003cbr\u003eVoltage positive sequence\u003cbr\u003eVoltage negative sequence\u003cbr\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003cbr\u003ePhasor diagram of currents or voltages\u003cbr\u003econtrol functions    Switchgear control and monitoring\u003cbr\u003eProgrammable switchgear interlocking\u003cbr\u003eLocal\/remote control\u003cbr\u003econtrollable switchgear devices    6 controlled + 2 monitored objects\u003cbr\u003enumber of setting groups    4\u003cbr\u003emonitoring functions    Trip circuit supervision 74\u003cbr\u003eCircuit breaker monitoring\u003cbr\u003eRelay self-monitoring\u003cbr\u003elogs and records    Event recording\u003cbr\u003eDisturbance recording\u003cbr\u003eTripping context\u003cbr\u003eRelay maintenance\u003cbr\u003eSwitchgear diagnosis type    VT supervision ANSI code: 60\u003cbr\u003eTrip circuit supervision ANSI code: 74\u003cbr\u003eConnections - terminals    Screw (digital input\/output)\u003cbr\u003eRing lugs (analog inputs and outputs)\u003cbr\u003eComplementary\u003cbr\u003eSoftware name    ESetup Easergy Pro: virtual simulation test\u003cbr\u003eDisplay type    LCD 192 x 96 pixels\u003cbr\u003eNumber of key    1 customizable\u003cbr\u003eLocal signalling    4 x LED\u003cbr\u003e6 x LED tri-colour programmable\u003cbr\u003eHeight    176 mm\u003cbr\u003eWidth    102 mm\u003cbr\u003eDepth    219 mm\u003cbr\u003eNet weight    2.5 kg\u003cbr\u003eEnvironment\u003cbr\u003eclimatic withstand    Exposure to cold conforming to IEC 60068-2-1\u003cbr\u003eExposure to dry heat conforming to IEC 60068-2-2\u003cbr\u003eExposure to damp heat in service conforming to IEC 60068-2-78\u003cbr\u003eExposure to damp heat in service conforming to IEC 60068-2-30\u003cbr\u003eTemperature variation conforming to IEC 60068-2-14\u003cbr\u003eSalt mist conforming to IEC 60068-2-52\u003cbr\u003eInfluence of corrosion\/gas test 2 conforming to IEC 60068-2-60\u003cbr\u003eInfluence of corrosion\/gas test 4 conforming to IEC 60068-2-60\u003cbr\u003eInfluence of corrosion\/gas test 2 conforming to IEC 60721-3-3\u003cbr\u003eInfluence of corrosion\/gas test 4 conforming to IEC 60721-3-3\u003cbr\u003eMechanical robustness    Vibrations (level: class 2) conforming to IEC 60255-21-1\u003cbr\u003eVibrations conforming to GOST 17516.1\u003cbr\u003eVibrations conforming to IACS E10\u003cbr\u003eShocks (level: class 2) conforming to IEC 60255-21-2\u003cbr\u003eEarthquakes (level: class 2) conforming to IEC 60255-21-3\u003cbr\u003eElectromagnetic compatibility    Emission tests class A conforming to CISPR 11\u003cbr\u003eEmission tests class A conforming to CISPR 32\u003cbr\u003eEmission tests conforming to IACS E10\u003cbr\u003eEMC immunity class 4 conforming to IEC 61000-4-2\u003cbr\u003eEMC immunity class 4 conforming to ANSI C37.90.3\u003cbr\u003eEMC immunity level 3 conforming to IEC 61000-4-3\u003cbr\u003eEMC immunity conforming to ANSI C37.90.2\u003cbr\u003eEMC immunity conforming to GOST 32137\u003cbr\u003eEMC immunity conforming to GOST 30804.4.3\u003cbr\u003eEMC immunity conforming to IACS E10\u003cbr\u003eEMC immunity level 5 conforming to IEC 61000-4-8\u003cbr\u003eEMC immunity level 5 conforming to IEC 61000-4-9\u003cbr\u003eEMC immunity level 5 conforming to IEC 61000-4-10\u003cbr\u003eEMC immunity level 3 conforming to IEC 61000-4-6\u003cbr\u003eEMC immunity level 3 conforming to IEC 61000-4-18\u003cbr\u003eEMC immunity conforming to ANSI C37.90.1\u003cbr\u003eEMC immunity conforming to IEC 61000-4-12\u003cbr\u003eEMC immunity conforming to GOST 30804.4.12\u003cbr\u003eEMC immunity level 4 conforming to IEC 61000-4-16\u003cbr\u003eEMC immunity level 4 conforming to IEC 61000-4-4\u003cbr\u003eEMC immunity level 4 conforming to IEC 61000-4-5\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAmbient air temperature for operation\u003cbr\u003e\u003c\/strong\u003e-40…85 °C ( 16 h )\u003cbr\u003e-40…70 °C ( 96 h )\u003cbr\u003eAmbient air temperature for storage    -40…85 °C\u003cbr\u003eIP degree of protection    IP54 conforming to IEC 60529\u003cbr\u003emaximum operating altitude    2000 m\u003cbr\u003eProtective treatment    Conformal coating conforming to IEC 60068-2-52:Kb\/1\u003cbr\u003eConformal coating conforming to IEC 60068-2-60:Ke\u003cbr\u003eConformal coating conforming to IEC 60721-3-3:3C2\u003cbr\u003eRelative humidity    0…93 % at 40 °C, without condensation, 56 days\u003cbr\u003e93…95 % at 25…55 °C, 6 cycles, 12 + 12 hours\u003cbr\u003ePacking Units\u003cbr\u003eUnit Type of Package 1    PCE\u003cbr\u003eNumber of Units in Package 1    1\u003cbr\u003ePackage 1 Height    30.0 cm\u003cbr\u003ePackage 1 Width    30.0 cm\u003cbr\u003ePackage 1 Length    40.0 cm\u003cbr\u003ePackage 1 Weight    3.0 kg\u003cbr\u003eContractual warranty\u003cbr\u003eWarranty (in months)    24\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":47671841816676,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/3791\/7796\/files\/files_14_27643dac-f5b9-4fa3-85e2-d6f9cc0dcc3b.png?v=1767959482","url":"https:\/\/www.jublipower.com\/products\/powerlogic%e2%84%a2-p5v20-24-250v-4vt-10di-8do","provider":"Jublipower","version":"1.0","type":"link"}