{"title":"Primary Gas Insulated Switchgear","description":"","products":[{"product_id":"gma","title":"GMA","description":"\u003cp\u003e\u003cstrong\u003eGMA\u003c\/strong\u003e\u003cbr\u003eGas-Insulated Switchgear up to 24kV\u003cbr\u003e\u003cstrong\u003ePart of SeT\u003c\/strong\u003e Series\u003cbr\u003eGas Insulated Switchgear (GIS)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompact and flexible primary switchgear\u003c\/strong\u003e\u003cbr\u003eOur experts have been developing and manufacturing primary MV Gas-Insulated Switchgear for over 30 years, with tens of thousands of cubicles installed. GMA offers optimised, affordable, and customised solutions to meet every need based on this experience.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFacts about GMA\u003c\/strong\u003e\u003cbr\u003eOur GMA Gas-Insulated Switchgear intends to simplify the life of our customers by:\u003cbr\u003e  • Being efficient to provide an optimized return on investment.\u003cbr\u003e  • Offering easy \u0026amp; simple interfaces to operate.\u003cbr\u003e  • Help improve safety.\u003cbr\u003eGMA fulfils those demands through its compact, friendly user and digitised design.\u003cbr\u003e  • Ratings up to 24 kV 2500 A and 31.5 kA\u003cbr\u003e  • Vacuum circuit Breaker design\u003cbr\u003e  • Sealed for Life gas-insulated system\u003cbr\u003e  • Internal Arc Classification (IAC) AFL(R) 1 s.\u003cbr\u003e\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":47666305433700,"sku":null,"price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/3791\/7796\/files\/files.png?v=1767933508"},{"product_id":"primary-gas-insulated-switchgear-gha-bus-tie-double-busbar-up-to-40-5kv-up-to-2500a-40ka","title":"Primary Gas Insulated Switchgear, GHA, bus tie, double busbar, up to 40.5kV, up to 2500A, 40kA","description":"\u003cp\u003e\u003cstrong\u003eEnvironmental Data\u003c\/strong\u003e\u003cbr\u003eUse Better\u003cbr\u003ePackaging made with recycled cardboard\u003cbr\u003eNo\u003cbr\u003eUse Longer\u003cbr\u003eRepair\u003cbr\u003eNo\u003cbr\u003eUse Again\u003cbr\u003eTake-back\u003cbr\u003eYes\u003c\/p\u003e\n\u003cp\u003eDocuments\u003c\/p\u003e\n\u003cp\u003eProduct Datasheet\u003c\/p\u003e\n\u003cp\u003eEnvironmental Disclosure\u003c\/p\u003e\n\u003cp\u003eSee all documents\u003cbr\u003e+ Lifecycle Services\u003cbr\u003eSort by:\u003cbr\u003eSelectService Plans\u003cbr\u003eService plan, EcoCare, GHA, advanced offer, 1 year duration, medium voltage high performance, connected services\u003cbr\u003eECRADVMVHIGH1Y\u003c\/p\u003e\n\u003cp\u003eService plan, EcoCare, GHA, advanced offer, 2 years duration, medium voltage high performance, connected services\u003cbr\u003eECRADVMVHIGH2Y\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003cbr\u003e\u003c\/strong\u003eMain\u003cbr\u003eMaster range    SeT Series\u003cbr\u003eRange of product    GHA\u003cbr\u003eFunctional unit    BS bus sectionalizer cubicle\u003cbr\u003eInsulation technology    Gas insulated switchgear\u003cbr\u003eType of Insulating gas    SF6\u003cbr\u003eNumber of phases    3\u003cbr\u003eNetwork type    AC\u003cbr\u003eType of installation    Indoor installation\u003cbr\u003eBusbar system    Double busbar\u003cbr\u003eBusbar description    Solid insulated busbar\u003cbr\u003eSwitching device    Circuit breaker\u003cbr\u003eStandards    IEC 62271-200\u003cbr\u003eRated voltage (Ur)    40.5 kV\u003cbr\u003eRated short-duration power frequency withstand voltage (Ud) \/ Common value    80 kV\u003cbr\u003eRated lightning impulse withstand voltage (Up) \/ Common value    185 kV\u003cbr\u003eRated frequency (fr)    50\/60 Hz\u003cbr\u003eRated continuous current of busbars (Ir)    2500 A\u003cbr\u003eRated continuous current (Ir)    800 A\u003cbr\u003e1250 A\u003cbr\u003e1600 A\u003cbr\u003e2000 A\u003cbr\u003e2500 A\u003cbr\u003eRated short-circuit breaking current (Isc)    40 kA\u003cbr\u003eRated short-circuit making current    100 kA 50 Hz\u003cbr\u003eRated short-time withstand current (Ik)    40 kA\u003cbr\u003eRated duration of short-circuit (tk)    3 s\u003cbr\u003eRated peak withstand current (Ip)    100 kA 50 Hz\u003cbr\u003eFilling level for insulation and\/or switching (Pre rel.)    0.05 MPa\u003cbr\u003eLoss of service continuity category    LSC2\u003cbr\u003eInternal arc classification    AFL\u003cbr\u003eAFLR\u003cbr\u003eRated arc fault current (IA)    40 kA\u003cbr\u003eRated arc fault duration (tA)    1 s\u003cbr\u003ePartition class    PM\u003cbr\u003eComplementary\u003cbr\u003eDegrees of protection provided by enclosures (IP code)    IP65 (functional unit)\u003cbr\u003eIP4X (LV control compartment)\u003cbr\u003eIP3X (cable compartment)\u003cbr\u003eIP2X (front of the mechanical operating panel)\u003cbr\u003eInstrument transformer    Current transformer\u003cbr\u003eVoltage transformer\u003cbr\u003eSensor type    TH110 thermal sensor\u003cbr\u003eCL110 environmental sensor\u003cbr\u003eProtection relay    Easergy P3\u003cbr\u003eEasergy Micom series 20\u003cbr\u003eEasergy Sepam series 60\u003cbr\u003eCable connection system    Inner cone\u003cbr\u003eOuter cone\u003cbr\u003eCable type    Single core\u003cbr\u003eMass    1560 kg\u003cbr\u003eHeight    2400 mm\u003cbr\u003eWidth    900 mm\u003cbr\u003eDepth    1400 mm\u003cbr\u003eEnvironment\u003cbr\u003eAmbient air temperature for operation    -5…40 °C\u003cbr\u003eAmbient air temperature for storage    -25…70 °C\u003cbr\u003eHumidity conditions    Average relative humidity over 24 h \u0026lt;= 95 %\u003cbr\u003eAverage relative humidity over 1 month \u0026lt;= 90 %\u003cbr\u003eOperating altitude    \u0026lt;= 1000 m\u003cbr\u003eContractual warranty\u003cbr\u003eWarranty (in months)    18\u003cbr\u003e \u003cbr\u003e\u003cstrong\u003eEnvironmental Data\u003c\/strong\u003e\u003cbr\u003eSchneider Electric aims to achieve Net Zero status by 2050 through supply chain partnerships, lower impact materials, and circularity via our ongoing “Use Better, Use Longer, Use Again” campaign to extend product lifetimes and recyclability.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Data explained\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eHow we assess product sustainability\u003c\/p\u003e\n\u003cp\u003eEnvironmental footprint\u003cbr\u003eEnvironmental Disclosure\u003cbr\u003eProduct Environmental Profile\u003cbr\u003eUse Better\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaterials and Substances\u003c\/strong\u003e\u003cbr\u003ePackaging made with recycled cardboard\u003cbr\u003eNo\u003cbr\u003ePackaging without single use plastic\u003cbr\u003eNo\u003cbr\u003eEU RoHS Directive\u003c\/p\u003e\n\u003cp\u003ePro-active compliance (Product out of EU RoHS legal scope)\u003cbr\u003eSCIP Number\u003cbr\u003e3c9a0db3-b9f0-4ecf-b953-4875be63a2cf\u003cbr\u003eREACh Regulation\u003cbr\u003eREACh Declaration\u003c\/p\u003e\n\u003cp\u003eUse Longer\u003cbr\u003eLifetime extension\u003cbr\u003eRepair\u003cbr\u003eNo\u003cbr\u003eUse Again\u003c\/p\u003e\n\u003cp\u003eRepack and remanufacture\u003cbr\u003eEnd of life manual availability\u003cbr\u003eEnd of Life Information\u003c\/p\u003e\n\u003cp\u003eTake-back\u003cbr\u003eYes\u003cbr\u003eDocuments\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":47666321293412,"sku":null,"price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/3791\/7796\/files\/files_1_d8982358-b8e2-40d1-a758-52b3a7d56105.png?v=1767933931"},{"product_id":"ws","title":"WS","description":"\u003cp\u003e\u003cstrong\u003eWS\u003c\/strong\u003e\u003cbr\u003eGas-Insulated Switchgear up to 36kV\u003cbr\u003e\u003cstrong\u003ePart of SeT\u003c\/strong\u003e Series\u003cbr\u003eGas Insulated Switchgear (GIS)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003cbr\u003e•    Gas-insulated switchgear up to 36 kV, 2500 A, 31.5 kA(3s)\u003cbr\u003e•    Busbars up to 3000A\u003cbr\u003e•    With vacuum circuit breaker\u003cbr\u003e•    Modular design of switchgear panels, single or double busbar\u003cbr\u003e•    All live parts are hermetically enclosed and gas insulated\u003cbr\u003e•    Metal enclosed and metal clad\u003cbr\u003e•    Panels can be extended without switching off the bus-bar\u003cbr\u003e•    Complies with the requirements of IEC, ANSI, GOST and China National Standard (CNS)\u003cbr\u003e\u003cstrong\u003eBenefits\u003c\/strong\u003e\u003cbr\u003e•    Gas insulation system sealed-for-life\u003cbr\u003e•    All live parts hermetically enclosed\u003cbr\u003e•    Insensitive to environmental influences\u003cbr\u003e•    Long service life and low maintenance\u003cbr\u003e•    Space-saving modular design\u003cbr\u003e•    User-friendly operation\u003cbr\u003e•    Reliable indication and interlocking\u003cbr\u003e•    Robust design with a comprehensive range of features\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":47666324897892,"sku":null,"price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/3791\/7796\/files\/files_2_f911b2bb-9874-4f7d-b83e-019c76ea35bf.png?v=1767934146"},{"product_id":"wi","title":"WI","description":"\u003cp\u003e\u003cstrong\u003eWI\u003c\/strong\u003e\u003cbr\u003eGas-Insulated Switchgear up to 52kV\u003cbr\u003e\u003cstrong\u003ePart of SeT\u003c\/strong\u003e Series\u003cbr\u003eGas Insulated Switchgear (GIS)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003cbr\u003eWI is a compact, modular GIS switchgear for Primary Distribution.\u003cbr\u003e \u003cbr\u003e•    Mainly for applications \u0026gt; 40.5 kV \u0026gt; 185 kV BIL, railway need\u003cbr\u003e•    Ratings up to 52 kV, 31.5kA, 2500A, 250 kV BIL\u003cbr\u003e•    Uses vacuum circuit breakers\u003cbr\u003e•    Circuit connected VT with device to break and isolate VTs HV termination\u003cbr\u003e•    Single and double busbar\u003cbr\u003e•    Three-phase enclosure\u003cbr\u003e•    One or two-phase design\u003cbr\u003e\u003cstrong\u003eBenefits\u003c\/strong\u003e\u003cbr\u003e•    Space saving\u003cbr\u003e•    Intuitive operator guidance\u003cbr\u003e•    Easy switching unit replacement\u003cbr\u003e•    Environment independent switchgear\u003cbr\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003cbr\u003eWI can be used in power stations, transformer substations, or Railway applications.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":47666333909092,"sku":null,"price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/3791\/7796\/files\/files_3_ec0f102e-b124-423f-b453-8ed91b9c7b9b.png?v=1767934499"},{"product_id":"powerlogic™-p5u20-24-250v-3ct-2io-4di-4do","title":"PowerLogic™ P5U20 24-250V 3CT 2Io 4DI-4DO","description":"\u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003cbr\u003eThe PowerLogic P5 is Schneider Electric's withdrawable protection and control relay for demanding medium voltage distribution applications. This current relay offers withdrawable design with backup memory function enabling industry-leading 10 minute recovery time. It provides redundant Ethernet including IEC 61850 as well as plug and play communication modules that can evolve with your application. The product embeds latest cybersecurity functionality to help prevent intentional mis-use and cyber-threats. PowerLogic P5 offers safety, security, and connectivity built on more than 100 years of experience in protection relays. The PowerLogic P5 protection relay can be applied to all types of MV distribution networks. It can be supplied with 24 to 250 VDC and 100 to 230 VAC. It works with conventional CTs. 3 phase current inputs, 1 standard neutral current input, 1 senstive neutral current input. It offers 4 digital inputs and 4 digital outputs and no communications. Communication modules can be added any time. The product dimensions are 180 mm in height (7.09 in), 102 mm in width (4.01 in) and 224 mm in depth 8.82 in) for a net weight of 2.5 kg (5.5 lbs). PowerLogic P5 is compliant with EN 60255-26, EN 60255-27 standard and with UL Standard. It provides Marine certification. This product can be flush mounted on the panel or in the rack. Flush mounting frames to ensure IP54 are available. Fixing and wiring accessories are included. Plug and play communication modules: Ethernet RSTP RJ45 (REL51038), Ethernet RSTP FO (REL51039), Ethernet HSR\/PRP FO (REL51033). And also RS485 serial RJ45 (REL51036), RS485 serial FO (REL51040), Extension\/backup memory (REL51034). IP54 flush mounting frame (REL51032), 8 temperature sensor module (59641), IRIG-B module (REL51045). connection cords (59660, 59661, 59662). eSetup Easergy Pro software with virtual injection testing and EcoStruxure Power Device app for simpler and safer operation and maintenance. Included with functions as per the datasheet below. For other configurations with additional functions and options, Please select via Product Selector.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003cbr\u003eMain\u003cbr\u003eRange of product    PowerLogic P5\u003cbr\u003eProduct or component type    Protection and control relay\u003cbr\u003eRelay application    Universal\u003cbr\u003eproduct reference    P5U20-AABA-BAAAA-BAEA\u003cbr\u003eMounting case size    20TE\u003cbr\u003eDevice mounting    Flush\u003cbr\u003eMounting mode    Withdrawable\u003cbr\u003epower supply    24...240 V DC\u003cbr\u003e100...230 V AC\u003cbr\u003emeasuring inputs    : 1\/5 A CT phase current 3\u003cbr\u003e: 1\/5 A CT residual current 1\u003cbr\u003e: 1 A CT residual current 1\u003cbr\u003eNumber of sensors    0 temperature sensor(s)\u003cbr\u003e0 arc sensor(s)\u003cbr\u003enumber of Digital Inputs (DI)    4\u003cbr\u003enumber of analogue inputs    0\u003cbr\u003enumber of Digital Outputs (DO)    3 DO\u003cbr\u003e1 watchdog\u003cbr\u003enumber of analogue outputs    0\u003cbr\u003ecommunication ports    USB port 2 front\u003cbr\u003ecommunication protocols    -\u003cbr\u003eCybersecurity    Port hardening\u003cbr\u003eFirmware signature\u003cbr\u003eClient IP address filter\u003cbr\u003eSecured communication with assciated tools\u003cbr\u003eSecurity policy management\u003cbr\u003eRole-based access control\u003cbr\u003eSecurity log\u003cbr\u003eLDAP\u003cbr\u003eRADIUS based user authentication\u003cbr\u003eIEC 62443-4-2 SL1\u003cbr\u003eprotection functions    Phase overcurrent 50\/51\u003cbr\u003eEarth fault overcurrent 50N\/51N\u003cbr\u003eCapacitor bank unbalance 51C\u003cbr\u003eBroken conductor 46 I2\/I1\u003cbr\u003eCurrent unbalance 46 I2\/I1\u003cbr\u003eCold load pick-up\u003cbr\u003eSwitch ON to fault (SOTF)\u003cbr\u003eH2 detection\u003cbr\u003eH5 detection\u003cbr\u003eBreaker failure 50BF\u003cbr\u003eRecloser 79\u003cbr\u003eThermal overload protection 49\u003cbr\u003ePhase undercurrent 37\u003cbr\u003eNegative sequence overcurrent 46\u003cbr\u003eExcessive starting time, locked rotor 48\/51LR\u003cbr\u003eMotor restart inhibition 66\u003cbr\u003eCapacitor overvoltage 59C\u003cbr\u003eLockout relay 86\u003cbr\u003eCT supervision 60\u003cbr\u003eProgrammable stages 99\u003cbr\u003eProgrammable logic\u003cbr\u003eProgrammable curve\u003cbr\u003emeasurement functions    Current 3-phase\u003cbr\u003eCurrent zero sequence\u003cbr\u003eCurrent positive sequence\u003cbr\u003eCurrent negative sequence\u003cbr\u003eCurrent ratio of negative and positive\u003cbr\u003eFrequency\u003cbr\u003ePhasor diagram of currents or voltages\u003cbr\u003eCurrent 2nd, 15th harmonics with THD\u003cbr\u003econtrol functions    Switchgear control and monitoring\u003cbr\u003eProgrammable switchgear interlocking\u003cbr\u003eLocal\/remote control\u003cbr\u003econtrollable switchgear devices    6 controlled + 2 monitored objects\u003cbr\u003enumber of setting groups    4\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eElectromagnetic compatibility\u003c\/strong\u003e\u003cbr\u003eEmission tests class A conforming to CISPR 11\u003cbr\u003eEmission tests class A conforming to CISPR 32\u003cbr\u003eEmission tests conforming to IACS E10\u003cbr\u003eEMC immunity class 4 conforming to IEC 61000-4-2\u003cbr\u003eEMC immunity class 4 conforming to ANSI C37.90.3\u003cbr\u003eEMC immunity level 3 conforming to IEC 61000-4-3\u003cbr\u003eEMC immunity conforming to ANSI C37.90.2\u003cbr\u003eEMC immunity conforming to GOST 32137\u003cbr\u003eEMC immunity conforming to GOST 30804.4.3\u003cbr\u003eEMC immunity conforming to IACS E10\u003cbr\u003eEMC immunity level 5 conforming to IEC 61000-4-8\u003cbr\u003eEMC immunity level 5 conforming to IEC 61000-4-9\u003cbr\u003eEMC immunity level 5 conforming to IEC 61000-4-10\u003cbr\u003eEMC immunity level 3 conforming to IEC 61000-4-6\u003cbr\u003eEMC immunity level 3 conforming to IEC 61000-4-18\u003cbr\u003eEMC immunity conforming to ANSI C37.90.1\u003cbr\u003eEMC immunity conforming to IEC 61000-4-12\u003cbr\u003eEMC immunity conforming to GOST 30804.4.12\u003cbr\u003eEMC immunity level 4 conforming to IEC 61000-4-16\u003cbr\u003eEMC immunity level 4 conforming to IEC 61000-4-4\u003cbr\u003eEMC immunity level 4 conforming to IEC 61000-4-5\u003cbr\u003eAmbient air temperature for operation    -40…85 °C ( 16 h )\u003cbr\u003e-40…70 °C ( 96 h )\u003cbr\u003eAmbient air temperature for storage    -40…85 °C\u003cbr\u003eIP degree of protection    IP54 conforming to IEC 60529\u003cbr\u003emaximum operating altitude    2000 m\u003cbr\u003eProtective treatment    Conformal coating conforming to IEC 60068-2-52:Kb\/1\u003cbr\u003eConformal coating conforming to IEC 60068-2-60:Ke\u003cbr\u003eConformal coating conforming to IEC 60721-3-3:3C2\u003cbr\u003eRelative humidity    0…93 % at 40 °C, without condensation, 56 days\u003cbr\u003e93…95 % at 25…55 °C, 6 cycles, 12 + 12 hours\u003cbr\u003ePacking Units\u003cbr\u003eUnit Type of Package 1    PCE\u003cbr\u003eNumber of Units in Package 1    1\u003cbr\u003ePackage 1 Height    30.0 cm\u003cbr\u003ePackage 1 Width    30.0 cm\u003cbr\u003ePackage 1 Length    40.0 cm\u003cbr\u003ePackage 1 Weight    3.0 kg\u003cbr\u003eLogistical informations\u003cbr\u003eCountry of origin    LV\u003cbr\u003eContractual warranty\u003cbr\u003eWarranty (in months)    24\u003cbr\u003e\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":47670837543012,"sku":null,"price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/3791\/7796\/files\/files_9_8a7e082b-05de-4340-bba5-f399c0258e5b.png?v=1767953720"},{"product_id":"powerlogic™-p5u20-24-250v-3ct-1csh-4di-4do","title":"PowerLogic™ P5U20 24-250V 3CT 1CSH 4DI-4DO","description":"\u003cp\u003e\u003cstrong\u003eEnvironmental Data\u003c\/strong\u003e\u003cbr\u003eTotal lifecycle Carbon footprint\u003cbr\u003e182\u003cbr\u003eUse Better\u003cbr\u003ePackaging made with recycled cardboard\u003cbr\u003eYes\u003cbr\u003eUse Longer\u003cbr\u003eRepair\u003cbr\u003eNo\u003cbr\u003eUse Again\u003cbr\u003eTake-back\u003cbr\u003eNo\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003cbr\u003eThe PowerLogic P5 is Schneider Electric's withdrawable protection and control relay for demanding medium voltage distribution applications. This current relay offers withdrawable design with backup memory function enabling industry-leading 10 minute recovery time. It provides redundant Ethernet including IEC 61850 as well as plug and play communication modules that can evolve with your application. The product embeds latest cybersecurity functionality to help prevent intentional mis-use and cyber-threats. PowerLogic P5 offers safety, security, and connectivity built on more than 100 years of experience in protection relays. The PowerLogic P5 protection relay can be applied to all types of MV distribution networks. It can be supplied with 24 to 250 VDC and 100 to 230 VAC. It works with conventional CTs. 3 phase current inputs, 1 Schneider Electric specific CSH neutral current input. It offers 4 digital inputs and 4 digital outputs and no communications. Communication modules can be added any time. The product dimensions are 180 mm in height (7.09 in), 102 mm in width (4.01 in) and 224 mm in depth 8.82 in) for a net weight of 2.5 kg (5.5 lbs). PowerLogic P5 is compliant with EN 60255-26, EN 60255-27 standard and with UL Standard. It provides Marine certification. This product can be flush mounted on the panel or in the rack. Flush mounting frames to ensure IP54 are available. Fixing and wiring accessories are included. Plug and play communication modules: Ethernet RSTP RJ45 (REL51038), Ethernet RSTP FO (REL51039), Ethernet HSR\/PRP FO (REL51033). And also RS485 serial RJ45 (REL51036), RS485 serial FO (REL51040), Extension\/backup memory (REL51034). IP54 flush mounting frame (REL51032), CSH core-balance CTs (59635, 59636, 59637), 8 temperature sensor module (59641), IRIG-B module (REL51045). connection cords (59660, 59661, 59662). eSetup Easergy Pro software with virtual injection testing and EcoStruxure Power Device app for simpler and safer operation and maintenance. Included with functions as per the datasheet below. For other configurations with additional functions and options, Please select via Product Selector.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003cbr\u003eMain\u003cbr\u003eRange of product    PowerLogic P5\u003cbr\u003eProduct or component type    Protection and control relay\u003cbr\u003eRelay application    Universal\u003cbr\u003eproduct reference    P5U20-AABA-CAAAA-BAEA\u003cbr\u003eMounting case size    20TE\u003cbr\u003eDevice mounting    Flush\u003cbr\u003eMounting mode    Withdrawable\u003cbr\u003epower supply    24...240 V DC\u003cbr\u003e100...230 V AC\u003cbr\u003emeasuring inputs    : 1\/5 A CT phase current 3\u003cbr\u003e: CSH residual current 1\u003cbr\u003eNumber of sensors    0 temperature sensor(s)\u003cbr\u003e0 arc sensor(s)\u003cbr\u003enumber of Digital Inputs (DI)    4\u003cbr\u003enumber of analogue inputs    0\u003cbr\u003enumber of Digital Outputs (DO)    3 DO\u003cbr\u003e1 watchdog\u003cbr\u003enumber of analogue outputs    0\u003cbr\u003ecommunication ports    USB port 2 front\u003cbr\u003ecommunication protocols    -\u003cbr\u003eCybersecurity    Port hardening\u003cbr\u003eFirmware signature\u003cbr\u003eClient IP address filter\u003cbr\u003eSecured communication with assciated tools\u003cbr\u003eSecurity policy management\u003cbr\u003eRole-based access control\u003cbr\u003eSecurity log\u003cbr\u003eLDAP\u003cbr\u003eRADIUS based user authentication\u003cbr\u003eIEC 62443-4-2 SL1\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eprotection functions\u003c\/strong\u003e  \u003cbr\u003ePhase overcurrent 50\/51\u003cbr\u003eEarth fault overcurrent 50N\/51N\u003cbr\u003eCapacitor bank unbalance 51C\u003cbr\u003eBroken conductor 46 I2\/I1\u003cbr\u003eCurrent unbalance 46 I2\/I1\u003cbr\u003eCold load pick-up\u003cbr\u003eSwitch ON to fault (SOTF)\u003cbr\u003eH2 detection\u003cbr\u003eH5 detection\u003cbr\u003eBreaker failure 50BF\u003cbr\u003eRecloser 79\u003cbr\u003eThermal overload protection 49\u003cbr\u003ePhase undercurrent 37\u003cbr\u003eNegative sequence overcurrent 46\u003cbr\u003eExcessive starting time, locked rotor 48\/51LR\u003cbr\u003eMotor restart inhibition 66\u003cbr\u003eCapacitor overvoltage 59C\u003cbr\u003eLockout relay 86\u003cbr\u003eCT supervision 60\u003cbr\u003eProgrammable stages 99\u003cbr\u003eProgrammable logic\u003cbr\u003eProgrammable curve\u003cbr\u003emeasurement functions    Current 3-phase\u003cbr\u003eCurrent zero sequence\u003cbr\u003eCurrent positive sequence\u003cbr\u003eCurrent negative sequence\u003cbr\u003eCurrent ratio of negative and positive\u003cbr\u003eFrequency\u003cbr\u003ePhasor diagram of currents or voltages\u003cbr\u003eCurrent 2nd, 15th harmonics with THD\u003cbr\u003econtrol functions    Switchgear control and monitoring\u003cbr\u003eProgrammable switchgear interlocking\u003cbr\u003eLocal\/remote control\u003cbr\u003econtrollable switchgear devices    6 controlled + 2 monitored objects\u003cbr\u003enumber of setting groups    4\u003cbr\u003emonitoring functions    Trip circuit supervision 74\u003cbr\u003eCircuit breaker monitoring\u003cbr\u003eRelay self-monitoring\u003cbr\u003elogs and records    Event recording\u003cbr\u003eDisturbance recording\u003cbr\u003eTripping context\u003cbr\u003eRelay maintenance\u003c\/p\u003e\n\u003cp\u003eSwitchgear diagnosis type    CT supervision ANSI code: 60\u003cbr\u003eTrip circuit supervision ANSI code: 74\u003cbr\u003eConnections - terminals    Screw (digital input\/output)\u003cbr\u003eRing lugs (analog inputs and outputs)\u003cbr\u003eComplementary\u003cbr\u003eSoftware name    ESetup Easergy Pro: virtual simulation test\u003cbr\u003eDisplay type    LCD 192 x 96 pixels\u003cbr\u003eNumber of key    1 customizable\u003cbr\u003eLocal signalling    4 x LED\u003cbr\u003e6 x LED tri-colour programmable\u003cbr\u003eHeight    176 mm\u003cbr\u003eWidth    102 mm\u003cbr\u003eDepth    219 mm\u003cbr\u003eNet weight    2.5 kg\u003cbr\u003eEnvironment\u003cbr\u003eclimatic withstand    Exposure to cold conforming to IEC 60068-2-1\u003cbr\u003eExposure to dry heat conforming to IEC 60068-2-2\u003cbr\u003eExposure to damp heat in service conforming to IEC 60068-2-78\u003cbr\u003eExposure to damp heat in service conforming to IEC 60068-2-30\u003cbr\u003eTemperature variation conforming to IEC 60068-2-14\u003cbr\u003eSalt mist conforming to IEC 60068-2-52\u003cbr\u003eInfluence of corrosion\/gas test 2 conforming to IEC 60068-2-60\u003cbr\u003eInfluence of corrosion\/gas test 4 conforming to IEC 60068-2-60\u003cbr\u003eInfluence of corrosion\/gas test 2 conforming to IEC 60721-3-3\u003cbr\u003eInfluence of corrosion\/gas test 4 conforming to IEC 60721-3-3\u003cbr\u003eMechanical robustness    Vibrations (level: class 2) conforming to IEC 60255-21-1\u003cbr\u003eVibrations conforming to GOST 17516.1\u003cbr\u003eVibrations conforming to IACS E10\u003cbr\u003eShocks (level: class 2) conforming to IEC 60255-21-2\u003cbr\u003eEarthquakes (level: class 2) conforming to IEC 60255-21-3\u003cbr\u003eElectromagnetic compatibility    Emission tests class A conforming to CISPR 11\u003cbr\u003eEmission tests class A conforming to CISPR 32\u003cbr\u003eEmission tests conforming to IACS E10\u003cbr\u003eEMC immunity class 4 conforming to IEC 61000-4-2\u003cbr\u003eEMC immunity class 4 conforming to ANSI C37.90.3\u003cbr\u003eEMC immunity level 3 conforming to IEC 61000-4-3\u003cbr\u003eEMC immunity conforming to ANSI C37.90.2\u003cbr\u003eEMC immunity conforming to GOST 32137\u003cbr\u003eEMC immunity conforming to GOST 30804.4.3\u003cbr\u003eEMC immunity conforming to IACS E10\u003cbr\u003eEMC immunity level 5 conforming to IEC 61000-4-8\u003cbr\u003eEMC immunity level 5 conforming to IEC 61000-4-9\u003cbr\u003eEMC immunity level 5 conforming to IEC 61000-4-10\u003cbr\u003eEMC immunity level 3 conforming to IEC 61000-4-6\u003cbr\u003eEMC immunity level 3 conforming to IEC 61000-4-18\u003cbr\u003eEMC immunity conforming to ANSI C37.90.1\u003cbr\u003eEMC immunity conforming to IEC 61000-4-12\u003cbr\u003eEMC immunity conforming to GOST 30804.4.12\u003cbr\u003eEMC immunity level 4 conforming to IEC 61000-4-16\u003cbr\u003eEMC immunity level 4 conforming to IEC 61000-4-4\u003cbr\u003eEMC immunity level 4 conforming to IEC 61000-4-5\u003cbr\u003eAmbient air temperature for operation    -40…85 °C ( 16 h )\u003cbr\u003e-40…70 °C ( 96 h )\u003cbr\u003eAmbient air temperature for storage    -40…85 °C\u003cbr\u003eIP degree of protection    IP54 conforming to IEC 60529\u003cbr\u003emaximum operating altitude    2000 m\u003cbr\u003eProtective treatment    Conformal coating conforming to IEC 60068-2-52:Kb\/1\u003cbr\u003eConformal coating conforming to IEC 60068-2-60:Ke\u003cbr\u003eConformal coating conforming to IEC 60721-3-3:3C2\u003cbr\u003eRelative humidity    0…93 % at 40 °C, without condensation, 56 days\u003cbr\u003e93…95 % at 25…55 °C, 6 cycles, 12 + 12 hours\u003cbr\u003ePacking Units\u003cbr\u003eUnit Type of Package 1    PCE\u003cbr\u003eNumber of Units in Package 1    1\u003cbr\u003ePackage 1 Height    30.0 cm\u003cbr\u003ePackage 1 Width    30.0 cm\u003cbr\u003ePackage 1 Length    40.0 cm\u003cbr\u003ePackage 1 Weight    3.0 kg\u003cbr\u003eContractual warranty\u003cbr\u003eWarranty (in months)    24\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":47671600349284,"sku":null,"price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/3791\/7796\/files\/files_10_999a6081-f121-4be2-a845-2e4a59bb2c18.png?v=1767954779"},{"product_id":"powerlogic™-p5u20-24-250v-3ct-2io-10di-8do","title":"PowerLogic™ P5U20 24-250V 3CT 2Io 10DI-8DO","description":"\u003cp\u003e\u003cstrong\u003eEnvironmental Data\u003c\/strong\u003e\u003cbr\u003eTotal lifecycle Carbon footprint\u003cbr\u003e182\u003cbr\u003eUse Better\u003cbr\u003ePackaging made with recycled cardboard\u003cbr\u003eYes\u003cbr\u003eUse Longer\u003cbr\u003eRepair\u003cbr\u003eNo\u003cbr\u003eUse Again\u003cbr\u003eTake-back\u003cbr\u003eNo\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003cbr\u003eThe PowerLogic P5 is Schneider Electric's withdrawable protection and control relay for demanding medium voltage distribution applications. This current relay offers withdrawable design with backup memory function enabling industry-leading 10 minute recovery time. It provides redundant Ethernet including IEC 61850 as well as plug and play communication modules that can evolve with your application. The product embeds latest cybersecurity functionality to help prevent intentional mis-use and cyber-threats. PowerLogic P5 offers safety, security, and connectivity built on more than 100 years of experience in protection relays. The PowerLogic P5 protection relay can be applied to all types of MV distribution networks. It can be supplied with 24 to 250 VDC and 100 to 230 VAC. It works with conventional CTs. 3 phase current inputs, 1 standard neutral current input, 1 senstive neutral current input. It offers 10 digital inputs and 8 digital outputs and no communications. Communication modules can be added any time. The product dimensions are 180 mm in height (7.09 in), 102 mm in width (4.01 in) and 224 mm in depth 8.82 in) for a net weight of 2.5 kg (5.5 lbs). PowerLogic P5 is compliant with EN 60255-26, EN 60255-27 standard and with UL Standard. It provides Marine certification. This product can be flush mounted on the panel or in the rack. Flush mounting frames to ensure IP54 are available. Fixing and wiring accessories are included. Plug and play communication modules: Ethernet RSTP RJ45 (REL51038), Ethernet RSTP FO (REL51039), Ethernet HSR\/PRP FO (REL51033). And also RS485 serial RJ45 (REL51036), RS485 serial FO (REL51040), Extension\/backup memory (REL51034). IP54 flush mounting frame (REL51032), 8 temperature sensor module (59641), IRIG-B module (REL51045). connection cords (59660, 59661, 59662). eSetup Easergy Pro software with virtual injection testing and EcoStruxure Power Device app for simpler and safer operation and maintenance. Included with functions as per the datasheet below. For other configurations with additional functions and options, Please select via Product Selector.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003cbr\u003eMain\u003cbr\u003eRange of product    PowerLogic P5\u003cbr\u003eProduct or component type    Protection and control relay\u003cbr\u003eRelay application    Universal\u003cbr\u003eproduct reference    P5U20-AABB-BAAAA-BAEA\u003cbr\u003eMounting case size    20TE\u003cbr\u003eDevice mounting    Flush\u003cbr\u003eMounting mode    Withdrawable\u003cbr\u003epower supply    24...240 V DC\u003cbr\u003e100...230 V AC\u003cbr\u003emeasuring inputs    : 1\/5 A CT phase current 3\u003cbr\u003e: 1\/5 A CT residual current 1\u003cbr\u003e: 1 A CT residual current 1\u003cbr\u003eNumber of sensors    0 temperature sensor(s)\u003cbr\u003e0 arc sensor(s)\u003cbr\u003enumber of Digital Inputs (DI)    10\u003cbr\u003enumber of analogue inputs    0\u003cbr\u003enumber of Digital Outputs (DO)    7 DO\u003cbr\u003e1 watchdog\u003cbr\u003enumber of analogue outputs    0\u003cbr\u003ecommunication ports    USB port 2 front\u003cbr\u003ecommunication protocols    -\u003cbr\u003eCybersecurity    Port hardening\u003cbr\u003eFirmware signature\u003cbr\u003eClient IP address filter\u003cbr\u003eSecured communication with assciated tools\u003cbr\u003eSecurity policy management\u003cbr\u003eRole-based access control\u003cbr\u003eSecurity log\u003cbr\u003eLDAP\u003cbr\u003eRADIUS based user authentication\u003cbr\u003eIEC 62443-4-2 SL1\u003cbr\u003eprotection functions    Phase overcurrent 50\/51\u003cbr\u003eEarth fault overcurrent 50N\/51N\u003cbr\u003eCapacitor bank unbalance 51C\u003cbr\u003eBroken conductor 46 I2\/I1\u003cbr\u003eCurrent unbalance 46 I2\/I1\u003cbr\u003eCold load pick-up\u003cbr\u003eSwitch ON to fault (SOTF)\u003cbr\u003eH2 detection\u003cbr\u003eH5 detection\u003cbr\u003eBreaker failure 50BF\u003cbr\u003eRecloser 79\u003cbr\u003eThermal overload protection 49\u003cbr\u003ePhase undercurrent 37\u003cbr\u003eNegative sequence overcurrent 46\u003cbr\u003eExcessive starting time, locked rotor 48\/51LR\u003cbr\u003eMotor restart inhibition 66\u003cbr\u003eCapacitor overvoltage 59C\u003cbr\u003eLockout relay 86\u003cbr\u003eCT supervision 60\u003cbr\u003eProgrammable stages 99\u003cbr\u003eProgrammable logic\u003cbr\u003eProgrammable curve\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003emeasurement functions\u003cbr\u003e\u003c\/strong\u003eCurrent 3-phase\u003cbr\u003eCurrent zero sequence\u003cbr\u003eCurrent positive sequence\u003cbr\u003eCurrent negative sequence\u003cbr\u003eCurrent ratio of negative and positive\u003cbr\u003eFrequency\u003cbr\u003ePhasor diagram of currents or voltages\u003cbr\u003eCurrent 2nd, 15th harmonics with THD\u003cbr\u003econtrol functions    Switchgear control and monitoring\u003cbr\u003eProgrammable switchgear interlocking\u003cbr\u003eLocal\/remote control\u003cbr\u003econtrollable switchgear devices    6 controlled + 2 monitored objects\u003cbr\u003enumber of setting groups    4\u003cbr\u003emonitoring functions    Trip circuit supervision 74\u003cbr\u003eCircuit breaker monitoring\u003cbr\u003eRelay self-monitoring\u003cbr\u003elogs and records    Event recording\u003cbr\u003eDisturbance recording\u003cbr\u003eTripping context\u003cbr\u003eRelay maintenance\u003cbr\u003eSwitchgear diagnosis type    CT supervision ANSI code: 60\u003cbr\u003eTrip circuit supervision ANSI code: 74\u003cbr\u003eConnections - terminals    Screw (digital input\/output)\u003cbr\u003eRing lugs (analog inputs and outputs)\u003cbr\u003eComplementary\u003cbr\u003eSoftware name    ESetup Easergy Pro: virtual simulation test\u003cbr\u003eDisplay type    LCD 192 x 96 pixels\u003cbr\u003eNumber of key    1 customizable\u003cbr\u003eLocal signalling    4 x LED\u003cbr\u003e6 x LED tri-colour programmable\u003cbr\u003eHeight    176 mm\u003cbr\u003eWidth    102 mm\u003c\/p\u003e\n\u003cp\u003eDepth    219 mm\u003cbr\u003eNet weight    2.5 kg\u003cbr\u003eEnvironment\u003cbr\u003eclimatic withstand    Exposure to cold conforming to IEC 60068-2-1\u003cbr\u003eExposure to dry heat conforming to IEC 60068-2-2\u003cbr\u003eExposure to damp heat in service conforming to IEC 60068-2-78\u003cbr\u003eExposure to damp heat in service conforming to IEC 60068-2-30\u003cbr\u003eTemperature variation conforming to IEC 60068-2-14\u003cbr\u003eSalt mist conforming to IEC 60068-2-52\u003cbr\u003eInfluence of corrosion\/gas test 2 conforming to IEC 60068-2-60\u003cbr\u003eInfluence of corrosion\/gas test 4 conforming to IEC 60068-2-60\u003cbr\u003eInfluence of corrosion\/gas test 2 conforming to IEC 60721-3-3\u003cbr\u003eInfluence of corrosion\/gas test 4 conforming to IEC 60721-3-3\u003cbr\u003eMechanical robustness    Vibrations (level: class 2) conforming to IEC 60255-21-1\u003cbr\u003eVibrations conforming to GOST 17516.1\u003cbr\u003eVibrations conforming to IACS E10\u003cbr\u003eShocks (level: class 2) conforming to IEC 60255-21-2\u003cbr\u003eEarthquakes (level: class 2) conforming to IEC 60255-21-3\u003cbr\u003eElectromagnetic compatibility    Emission tests class A conforming to CISPR 11\u003cbr\u003eEmission tests class A conforming to CISPR 32\u003cbr\u003eEmission tests conforming to IACS E10\u003cbr\u003eEMC immunity class 4 conforming to IEC 61000-4-2\u003cbr\u003eEMC immunity class 4 conforming to ANSI C37.90.3\u003cbr\u003eEMC immunity level 3 conforming to IEC 61000-4-3\u003cbr\u003eEMC immunity conforming to ANSI C37.90.2\u003cbr\u003eEMC immunity conforming to GOST 32137\u003cbr\u003eEMC immunity conforming to GOST 30804.4.3\u003cbr\u003eEMC immunity conforming to IACS E10\u003cbr\u003eEMC immunity level 5 conforming to IEC 61000-4-8\u003cbr\u003eEMC immunity level 5 conforming to IEC 61000-4-9\u003cbr\u003eEMC immunity level 5 conforming to IEC 61000-4-10\u003cbr\u003eEMC immunity level 3 conforming to IEC 61000-4-6\u003cbr\u003eEMC immunity level 3 conforming to IEC 61000-4-18\u003cbr\u003eEMC immunity conforming to ANSI C37.90.1\u003cbr\u003eEMC immunity conforming to IEC 61000-4-12\u003cbr\u003eEMC immunity conforming to GOST 30804.4.12\u003cbr\u003eEMC immunity level 4 conforming to IEC 61000-4-16\u003cbr\u003eEMC immunity level 4 conforming to IEC 61000-4-4\u003cbr\u003eEMC immunity level 4 conforming to IEC 61000-4-5\u003cbr\u003eAmbient air temperature for operation    -40…85 °C ( 16 h )\u003cbr\u003e-40…70 °C ( 96 h )\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eAmbient air temperature for storage    -40…85 °C\u003cbr\u003eIP degree of protection    IP54 conforming to IEC 60529\u003cbr\u003emaximum operating altitude    2000 m\u003cbr\u003eProtective treatment    Conformal coating conforming to IEC 60068-2-52:Kb\/1\u003cbr\u003eConformal coating conforming to IEC 60068-2-60:Ke\u003cbr\u003eConformal coating conforming to IEC 60721-3-3:3C2\u003cbr\u003eRelative humidity    0…93 % at 40 °C, without condensation, 56 days\u003cbr\u003e93…95 % at 25…55 °C, 6 cycles, 12 + 12 hours\u003cbr\u003ePacking Units\u003cbr\u003eUnit Type of Package 1    PCE\u003cbr\u003eNumber of Units in Package 1    1\u003cbr\u003ePackage 1 Height    30.0 cm\u003cbr\u003ePackage 1 Width    30.0 cm\u003cbr\u003ePackage 1 Length    40.0 cm\u003cbr\u003ePackage 1 Weight    3.0 kg\u003cbr\u003eContractual warranty\u003cbr\u003eWarranty (in months)    24\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":47671660970084,"sku":null,"price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/3791\/7796\/files\/files_11_ed460ac3-3fa9-4b0e-b11b-425f1d6ec896.png?v=1767955436"},{"product_id":"powerlogic™-p5u20-24-250v-3ct-1csh-10di-8do","title":"PowerLogic™ P5U20 24-250V 3CT 1CSH 10DI-8DO","description":"\u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003cbr\u003eThe PowerLogic P5 is Schneider Electric's withdrawable protection and control relay for demanding medium voltage distribution applications. This current relay offers withdrawable design with backup memory function enabling industry-leading 10 minute recovery time. It provides redundant Ethernet including IEC 61850 as well as plug and play communication modules that can evolve with your application. The product embeds latest cybersecurity functionality to help prevent intentional mis-use and cyber-threats. PowerLogic P5 offers safety, security, and connectivity built on more than 100 years of experience in protection relays. The PowerLogic P5 protection relay can be applied to all types of MV distribution networks. It can be supplied with 24 to 250 VDC and 100 to 230 VAC. It works with conventional CTs. 3 phase current inputs, 1 Schneider Electric specific CSH neutral current input. It offers 10 digital inputs and 8 digital outputs and no communications. Communication modules can be added any time. The product dimensions are 180 mm in height (7.09 in), 102 mm in width (4.01 in) and 224 mm in depth 8.82 in) for a net weight of 2.5 kg (5.5 lbs). PowerLogic P5 is compliant with EN 60255-26, EN 60255-27 standard and with UL Standard. It provides Marine certification. This product can be flush mountedon the panel or in the rack. Flush mounting frames to ensure IP54 are available. Fixing and wiring accessories are included. Plug and play communication modules: Ethernet RSTP RJ45 (REL51038), Ethernet RSTP FO (REL51039), Ethernet HSR\/PRP FO (REL51033). And also RS485 serial RJ45 (REL51036), RS485 serial FO (REL51040), Extension\/backup memory (REL51034). IP54 flush mounting frame (REL51032), CSH core-balance CTs (59635, 59636, 59637), 8 temperature sensor module (59641), IRIG-B module (REL51045). connection cords (59660, 59661, 59662). eSetup Easergy Pro software with virtual injection testing and EcoStruxure Power Device app for simpler and safer operation and maintenance. Included with functions as per the datasheet below. For other configurations with additional functions and options, Please select via Product Selector.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003cbr\u003eMain\u003cbr\u003eRange of product    PowerLogic P5\u003cbr\u003eProduct or component type    Protection and control relay\u003cbr\u003eRelay application    Universal\u003cbr\u003eproduct reference    P5U20-AABB-CAAAA-BAEA\u003cbr\u003eMounting case size    20TE\u003cbr\u003eDevice mounting    Flush\u003cbr\u003eMounting mode    Withdrawable\u003cbr\u003epower supply    24...240 V DC\u003cbr\u003e100...230 V AC\u003cbr\u003emeasuring inputs    : 1\/5 A CT phase current 3\u003cbr\u003e: CSH residual current 1\u003cbr\u003eNumber of sensors    0 temperature sensor(s)\u003cbr\u003e0 arc sensor(s)\u003cbr\u003enumber of Digital Inputs (DI)    10\u003cbr\u003enumber of analogue inputs    0\u003cbr\u003enumber of Digital Outputs (DO)    7 DO\u003cbr\u003e1 watchdog\u003cbr\u003enumber of analogue outputs    0\u003cbr\u003ecommunication ports    USB port 2 front\u003cbr\u003ecommunication protocols    -\u003cbr\u003eCybersecurity    Port hardening\u003cbr\u003eFirmware signature\u003cbr\u003eClient IP address filter\u003cbr\u003eSecured communication with assciated tools\u003cbr\u003eSecurity policy management\u003cbr\u003eRole-based access control\u003cbr\u003eSecurity log\u003cbr\u003eLDAP\u003cbr\u003eRADIUS based user authentication\u003cbr\u003eIEC 62443-4-2 SL1\u003cbr\u003e\u003cstrong\u003eprotection functions\u003cbr\u003e\u003c\/strong\u003ePhase overcurrent 50\/51\u003cbr\u003eEarth fault overcurrent 50N\/51N\u003cbr\u003eCapacitor bank unbalance 51C\u003cbr\u003eBroken conductor 46 I2\/I1\u003cbr\u003eCurrent unbalance 46 I2\/I1\u003cbr\u003eCold load pick-up\u003cbr\u003eSwitch ON to fault (SOTF)\u003cbr\u003eH2 detection\u003cbr\u003eH5 detection\u003cbr\u003eBreaker failure 50BF\u003cbr\u003eRecloser 79\u003cbr\u003eThermal overload protection 49\u003cbr\u003ePhase undercurrent 37\u003cbr\u003eNegative sequence overcurrent 46\u003cbr\u003eExcessive starting time, locked rotor 48\/51LR\u003cbr\u003eMotor restart inhibition 66\u003cbr\u003eCapacitor overvoltage 59C\u003cbr\u003eLockout relay 86\u003cbr\u003eCT supervision 60\u003cbr\u003eProgrammable stages 99\u003cbr\u003eProgrammable logic\u003cbr\u003eProgrammable curve\u003cbr\u003e\u003cstrong\u003emeasurement functions\u003c\/strong\u003e\u003cbr\u003eCurrent 3-phase\u003cbr\u003eCurrent zero sequence\u003cbr\u003eCurrent positive sequence\u003cbr\u003eCurrent negative sequence\u003cbr\u003eCurrent ratio of negative and positive\u003cbr\u003eFrequency\u003cbr\u003ePhasor diagram of currents or voltages\u003cbr\u003eCurrent 2nd, 15th harmonics with THD\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003econtrol functions\u003cbr\u003e\u003c\/strong\u003eSwitchgear control and monitoring\u003cbr\u003eProgrammable switchgear interlocking\u003cbr\u003eLocal\/remote control\u003cbr\u003econtrollable switchgear devices    6 controlled + 2 monitored objects\u003cbr\u003enumber of setting groups    4\u003cbr\u003emonitoring functions    Trip circuit supervision 74\u003cbr\u003eCircuit breaker monitoring\u003cbr\u003eRelay self-monitoring\u003cbr\u003elogs and records    Event recording\u003cbr\u003eDisturbance recording\u003cbr\u003eTripping context\u003cbr\u003eRelay maintenance\u003cbr\u003eSwitchgear diagnosis type    CT supervision ANSI code: 60\u003cbr\u003eTrip circuit supervision ANSI code: 74\u003cbr\u003eConnections - terminals    Screw (digital input\/output)\u003cbr\u003eRing lugs (analog inputs and outputs)\u003cbr\u003eComplementary\u003cbr\u003eSoftware name    ESetup Easergy Pro: virtual simulation test\u003cbr\u003eDisplay type    LCD 192 x 96 pixels\u003cbr\u003eNumber of key    1 customizable\u003cbr\u003eLocal signalling    4 x LED\u003cbr\u003e6 x LED tri-colour programmable\u003cbr\u003eHeight    176 mm\u003cbr\u003eWidth    102 mm\u003cbr\u003eDepth    219 mm\u003cbr\u003eNet weight    2.5 kg\u003cbr\u003eEnvironment\u003cbr\u003eclimatic withstand    Exposure to cold conforming to IEC 60068-2-1\u003cbr\u003eExposure to dry heat conforming to IEC 60068-2-2\u003cbr\u003eExposure to damp heat in service conforming to IEC 60068-2-78\u003cbr\u003eExposure to damp heat in service conforming to IEC 60068-2-30\u003cbr\u003eTemperature variation conforming to IEC 60068-2-14\u003cbr\u003eSalt mist conforming to IEC 60068-2-52\u003cbr\u003eInfluence of corrosion\/gas test 2 conforming to IEC 60068-2-60\u003cbr\u003eInfluence of corrosion\/gas test 4 conforming to IEC 60068-2-60\u003cbr\u003eInfluence of corrosion\/gas test 2 conforming to IEC 60721-3-3\u003cbr\u003eInfluence of corrosion\/gas test 4 conforming to IEC 60721-3-3\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical robustness\u003cbr\u003e\u003c\/strong\u003eVibrations (level: class 2) conforming to IEC 60255-21-1\u003cbr\u003eVibrations conforming to GOST 17516.1\u003cbr\u003eVibrations conforming to IACS E10\u003cbr\u003eShocks (level: class 2) conforming to IEC 60255-21-2\u003cbr\u003eEarthquakes (level: class 2) conforming to IEC 60255-21-3\u003cbr\u003eElectromagnetic compatibility    Emission tests class A conforming to CISPR 11\u003cbr\u003eEmission tests class A conforming to CISPR 32\u003cbr\u003eEmission tests conforming to IACS E10\u003cbr\u003eEMC immunity class 4 conforming to IEC 61000-4-2\u003cbr\u003eEMC immunity class 4 conforming to ANSI C37.90.3\u003cbr\u003eEMC immunity level 3 conforming to IEC 61000-4-3\u003cbr\u003eEMC immunity conforming to ANSI C37.90.2\u003cbr\u003eEMC immunity conforming to GOST 32137\u003cbr\u003eEMC immunity conforming to GOST 30804.4.3\u003cbr\u003eEMC immunity conforming to IACS E10\u003cbr\u003eEMC immunity level 5 conforming to IEC 61000-4-8\u003cbr\u003eEMC immunity level 5 conforming to IEC 61000-4-9\u003cbr\u003eEMC immunity level 5 conforming to IEC 61000-4-10\u003cbr\u003eEMC immunity level 3 conforming to IEC 61000-4-6\u003cbr\u003eEMC immunity level 3 conforming to IEC 61000-4-18\u003cbr\u003eEMC immunity conforming to ANSI C37.90.1\u003cbr\u003eEMC immunity conforming to IEC 61000-4-12\u003cbr\u003eEMC immunity conforming to GOST 30804.4.12\u003cbr\u003eEMC immunity level 4 conforming to IEC 61000-4-16\u003cbr\u003eEMC immunity level 4 conforming to IEC 61000-4-4\u003cbr\u003eEMC immunity level 4 conforming to IEC 61000-4-5\u003cbr\u003eAmbient air temperature for operation    -40…85 °C ( 16 h )\u003cbr\u003e-40…70 °C ( 96 h )\u003cbr\u003eAmbient air temperature for storage    -40…85 °C\u003cbr\u003eIP degree of protection    IP54 conforming to IEC 60529\u003cbr\u003emaximum operating altitude    2000 m\u003cbr\u003eProtective treatment    Conformal coating conforming to IEC 60068-2-52:Kb\/1\u003cbr\u003eConformal coating conforming to IEC 60068-2-60:Ke\u003cbr\u003eConformal coating conforming to IEC 60721-3-3:3C2\u003cbr\u003eRelative humidity    0…93 % at 40 °C, without condensation, 56 days\u003cbr\u003e93…95 % at 25…55 °C, 6 cycles, 12 + 12 hours\u003cbr\u003ePacking Units\u003cbr\u003eUnit Type of Package 1    PCE\u003cbr\u003eNumber of Units in Package 1    1\u003cbr\u003ePackage 1 Height    30.000 cm\u003cbr\u003ePackage 1 Width    30.000 cm\u003cbr\u003ePackage 1 Length    40.000 cm\u003cbr\u003ePackage 1 Weight    3.000 kg\u003cbr\u003eContractual warranty\u003cbr\u003eWarranty (in months)    24\u003cbr\u003e\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":47671684202596,"sku":null,"price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/3791\/7796\/files\/files_12_58a87eaf-b231-4277-adc7-3eb229582789.png?v=1767955936"},{"product_id":"powerlogic™-p5v20-24-250v-4vt-4di-4do","title":"PowerLogic™ P5V20 24-250V 4VT 4DI-4DO","description":"\u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003cbr\u003eThe PowerLogic P5 is Schneider Electric's withdrawable protection and control relay for demanding medium voltage distribution applications. This voltage relay offers withdrawable design with backup memory function enabling industry-leading 10 minute recovery time. It provides redundant Ethernet including IEC 61850 as well as plug and play communication modules that can evolve with your application. The product embeds latest cybersecurity functionality to help prevent intentional mis-use and cyber-threats. PowerLogic P5 offers safety, security, and connectivity built on more than 100 years of experience in protection relays. The PowerLogic P5 protection relay can be applied to all types of MV distribution networks. It can be supplied with 24 to 250 VDC and 100 to 230 VAC. It works with conventional VTs. 3 phase voltage inputs, 1 neutral voltage input. It offers 4 digital inputs and 4 digital outputs and no communications. Communication modules can be added any time. The product dimensions are 180 mm in height (7.09 in), 102 mm in width (4.01 in) and 224 mm in depth 8.82 in) for a net weight of 2.5 kg (5.5 lbs). PowerLogic P5 is compliant with EN 60255-26, EN 60255-27 standard and with UL Standard. It provides Marine certification. This product can be flush mounted on the panel or in the rack. Flush mounting frames to ensure IP54 are available. Fixing and wiring accessories are included. Plug and play communication modules:Ethernet RSTP RJ45 (REL51038), Ethernet RSTP FO (REL51039), Ethernet HSR\/PRP FO (REL51033). And also RS485 serial RJ45 (REL51036), RS485 serial FO (REL51040), Extension\/backup memory (REL51034). IP54 flush mounting frame (REL51032), IRIG-B module (REL51045). connection cords (59660, 59661, 59662). eSetup Easergy Pro software with virtual injection testing and EcoStruxure Power Device app for simpler and safer operation and maintenance. Included with functions as per the datasheet below. For other configurations with additional functions and options, Please select via Product Selector.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003cbr\u003eMain\u003cbr\u003eRange of product    PowerLogic P5\u003cbr\u003eProduct or component type    Protection and control relay\u003cbr\u003eRelay application    Voltage\u003cbr\u003eproduct reference    P5V20-AABA-DAAAA-BAEA\u003cbr\u003eMounting case size    20TE\u003cbr\u003eDevice mounting    Flush\u003cbr\u003eMounting mode    Withdrawable\u003cbr\u003epower supply    24...240 V DC\u003cbr\u003e100...230 V AC\u003cbr\u003emeasuring inputs    : VT voltage 4\u003cbr\u003eNumber of sensors    0 temperature sensor(s)\u003cbr\u003e0 arc sensor(s)\u003cbr\u003enumber of Digital Inputs (DI)    4\u003cbr\u003enumber of analogue inputs    0\u003cbr\u003enumber of Digital Outputs (DO)    3 DO\u003cbr\u003e1 watchdog\u003cbr\u003enumber of analogue outputs    0\u003cbr\u003ecommunication ports    USB port 2 front\u003cbr\u003ecommunication protocols    -\u003cbr\u003eCybersecurity    Port hardening\u003cbr\u003eFirmware signature\u003cbr\u003eClient IP address filter\u003cbr\u003eSecured communication with assciated tools\u003cbr\u003eSecurity policy management\u003cbr\u003eRole-based access control\u003cbr\u003eSecurity log\u003cbr\u003eLDAP\u003cbr\u003eRADIUS based user authentication\u003cbr\u003eIEC 62443-4-2 SL1\u003cbr\u003eprotection functions    Overvoltage\u003cbr\u003eUndervoltage\u003cbr\u003ePositive sequence undervoltage 27P\u003cbr\u003eEarth fault overvoltage 59N\u003cbr\u003eUnderfrequency 81\/81N\u003cbr\u003eRate of change of frequency 81R\u003cbr\u003eSynchro-check\u003cbr\u003eBreaker failure 50BF\u003cbr\u003eLockout relay\u003cbr\u003eVT supervision\u003cbr\u003eProgrammable stages\u003cbr\u003eProgrammable curve\u003cbr\u003emeasurement functions    Voltage 3-phase\u003cbr\u003eVoltage residual\u003cbr\u003eVoltage zero sequence\u003cbr\u003eVoltage positive sequence\u003cbr\u003eVoltage negative sequence\u003cbr\u003eFrequency\u003cbr\u003ePhasor diagram of currents or voltages\u003cbr\u003econtrol functions    Switchgear control and monitoring\u003cbr\u003eProgrammable switchgear interlocking\u003cbr\u003eLocal\/remote control\u003cbr\u003econtrollable switchgear devices    6 controlled + 2 monitored objects\u003cbr\u003enumber of setting groups    4\u003cbr\u003emonitoring functions    Trip circuit supervision 74\u003cbr\u003eCircuit breaker monitoring\u003cbr\u003eRelay self-monitoring\u003cbr\u003elogs and records    Event recording\u003cbr\u003eDisturbance recording\u003cbr\u003eTripping context\u003cbr\u003eRelay maintenance\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSwitchgear diagnosis\u003c\/strong\u003e \u003cbr\u003etype    VT supervision ANSI code: 60\u003cbr\u003eTrip circuit supervision ANSI code: 74\u003cbr\u003eConnections - terminals    Screw (digital input\/output)\u003cbr\u003eRing lugs (analog inputs and outputs)\u003cbr\u003eComplementary\u003cbr\u003eSoftware name    ESetup Easergy Pro: virtual simulation test\u003cbr\u003eDisplay type    LCD 192 x 96 pixels\u003cbr\u003eNumber of key    1 customizable\u003cbr\u003eLocal signalling    4 x LED\u003cbr\u003e6 x LED tri-colour programmable\u003cbr\u003eHeight    176 mm\u003cbr\u003eWidth    102 mm\u003cbr\u003eDepth    219 mm\u003cbr\u003eNet weight    2.5 kg\u003cbr\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003cbr\u003eclimatic withstand    Exposure to cold conforming to IEC 60068-2-1\u003cbr\u003eExposure to dry heat conforming to IEC 60068-2-2\u003cbr\u003eExposure to damp heat in service conforming to IEC 60068-2-78\u003cbr\u003eExposure to damp heat in service conforming to IEC 60068-2-30\u003cbr\u003eTemperature variation conforming to IEC 60068-2-14\u003cbr\u003eSalt mist conforming to IEC 60068-2-52\u003cbr\u003eInfluence of corrosion\/gas test 2 conforming to IEC 60068-2-60\u003cbr\u003eInfluence of corrosion\/gas test 4 conforming to IEC 60068-2-60\u003cbr\u003eInfluence of corrosion\/gas test 2 conforming to IEC 60721-3-3\u003cbr\u003eInfluence of corrosion\/gas test 4 conforming to IEC 60721-3-3\u003cbr\u003eMechanical robustness    Vibrations (level: class 2) conforming to IEC 60255-21-1\u003cbr\u003eVibrations conforming to GOST 17516.1\u003cbr\u003eVibrations conforming to IACS E10\u003cbr\u003eShocks (level: class 2) conforming to IEC 60255-21-2\u003cbr\u003eEarthquakes (level: class 2) conforming to IEC 60255-21-3\u003cbr\u003eElectromagnetic compatibility    Emission tests class A conforming to CISPR 11\u003cbr\u003eEmission tests class A conforming to CISPR 32\u003cbr\u003eEmission tests conforming to IACS E10\u003cbr\u003eEMC immunity class 4 conforming to IEC 61000-4-2\u003cbr\u003eEMC immunity class 4 conforming to ANSI C37.90.3\u003cbr\u003eEMC immunity level 3 conforming to IEC 61000-4-3\u003cbr\u003eEMC immunity conforming to ANSI C37.90.2\u003cbr\u003eEMC immunity conforming to GOST 32137\u003cbr\u003eEMC immunity conforming to GOST 30804.4.3\u003cbr\u003eEMC immunity conforming to IACS E10\u003cbr\u003eEMC immunity level 5 conforming to IEC 61000-4-8\u003cbr\u003eEMC immunity level 5 conforming to IEC 61000-4-9\u003cbr\u003eEMC immunity level 5 conforming to IEC 61000-4-10\u003cbr\u003eEMC immunity level 3 conforming to IEC 61000-4-6\u003cbr\u003eEMC immunity level 3 conforming to IEC 61000-4-18\u003cbr\u003eEMC immunity conforming to ANSI C37.90.1\u003cbr\u003eEMC immunity conforming to IEC 61000-4-12\u003cbr\u003eEMC immunity conforming to GOST 30804.4.12\u003cbr\u003eEMC immunity level 4 conforming to IEC 61000-4-16\u003cbr\u003eEMC immunity level 4 conforming to IEC 61000-4-4\u003cbr\u003eEMC immunity level 4 conforming to IEC 61000-4-5\u003c\/p\u003e\n\u003cp\u003eAmbient air temperature for operation    -40…85 °C ( 16 h )\u003cbr\u003e-40…70 °C ( 96 h )\u003cbr\u003eAmbient air temperature for storage    -40…85 °C\u003cbr\u003eIP degree of protection    IP54 conforming to IEC 60529\u003cbr\u003emaximum operating altitude    2000 m\u003cbr\u003eProtective treatment    Conformal coating conforming to IEC 60068-2-52:Kb\/1\u003cbr\u003eConformal coating conforming to IEC 60068-2-60:Ke\u003cbr\u003eConformal coating conforming to IEC 60721-3-3:3C2\u003cbr\u003eRelative humidity    0…93 % at 40 °C, without condensation, 56 days\u003cbr\u003e93…95 % at 25…55 °C, 6 cycles, 12 + 12 hours\u003cbr\u003ePacking Units\u003cbr\u003eUnit Type of Package 1    PCE\u003cbr\u003eNumber of Units in Package 1    1\u003cbr\u003ePackage 1 Height    30.0 cm\u003cbr\u003ePackage 1 Width    30.0 cm\u003cbr\u003ePackage 1 Length    40.0 cm\u003cbr\u003ePackage 1 Weight    3.0 kg\u003cbr\u003eContractual warranty\u003cbr\u003eWarranty (in months)    24\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":47671817994340,"sku":null,"price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/3791\/7796\/files\/files_13_0023d2ab-f431-4d5f-928e-3efa4a398334.png?v=1767958876"},{"product_id":"powerlogic™-p5v20-24-250v-4vt-10di-8do","title":"PowerLogic™ P5V20 24-250V 4VT 10DI-8DO","description":"\u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003cbr\u003eThe PowerLogic P5 is Schneider Electric's withdrawable protection and control relay for demanding medium voltage distribution applications. This voltage relay offers withdrawable design with backup memory function enabling industry-leading 10 minute recovery time. It provides redundant Ethernet including IEC 61850 as well as plug and play communication modules that can evolve with your application. The product embeds latest cybersecurity functionality to help prevent intentional mis-use and cyber-threats. PowerLogic P5 offers safety, security, and connectivity built on more than 100 years of experience in protection relays. The PowerLogic P5 protection relay can be applied to all types of MV distribution networks. It can be supplied with 24 to 250 VDC and 100 to 230 VAC. It works with conventional VTs. 3 phase voltage inputs, 1 neutral voltage input. It offers 10 digital inputs and 8 digital outputs and no communications. Communication modules can be added any time. The product dimensions are 180 mm in height (7.09 in), 102 mm in width (4.01 in) and 224 mm in depth 8.82 in) for a net weight of 2.5 kg (5.5 lbs). PowerLogic P5 is compliant with EN 60255-26, EN 60255-27 standard and with UL Standard. It provides Marine certification. This product can be flush mounted on the panel orin the rack. Flush mounting frames to ensure IP54 are available. Fixing and wiring accessories are included. Plug and play communication modules: Ethernet RSTP RJ45 (REL51038), Ethernet RSTP FO (REL51039), Ethernet HSR\/PRP FO (REL51033). And also RS485 serial RJ45 (REL51036), RS485 serial FO (REL51040), Extension\/backup memory (REL51034). IP54 flush mounting frame (REL51032), IRIG-B module (REL51045). connection cords (59660, 59661, 59662). eSetup Easergy Pro software with virtual injection testing and EcoStruxure Power Device app for simpler and safer operation and maintenance. Included with functions as per the datasheet below. For other configurations with additional functions and options, Please select via Product Selector.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003cbr\u003eMain\u003cbr\u003eRange of product    PowerLogic P5\u003cbr\u003eProduct or component type    Protection and control relay\u003cbr\u003eRelay application    Voltage\u003cbr\u003eproduct reference    P5V20-AABB-DAAAA-BAEA\u003cbr\u003eMounting case size    20TE\u003cbr\u003eDevice mounting    Flush\u003cbr\u003eMounting mode    Withdrawable\u003cbr\u003epower supply    24...240 V DC\u003cbr\u003e100...230 V AC\u003cbr\u003emeasuring inputs    : VT voltage 4\u003cbr\u003eNumber of sensors    0 temperature sensor(s)\u003cbr\u003e0 arc sensor(s)\u003cbr\u003enumber of Digital Inputs (DI)    10\u003cbr\u003enumber of analogue inputs    0\u003cbr\u003enumber of Digital Outputs (DO)    7 DO\u003cbr\u003e1 watchdog\u003cbr\u003enumber of analogue outputs    0\u003cbr\u003ecommunication ports    USB port 2 front\u003cbr\u003ecommunication protocols    -\u003cbr\u003eCybersecurity    Port hardening\u003cbr\u003eFirmware signature\u003cbr\u003eClient IP address filter\u003cbr\u003eSecured communication with assciated tools\u003cbr\u003eSecurity policy management\u003cbr\u003eRole-based access control\u003cbr\u003eSecurity log\u003cbr\u003eLDAP\u003cbr\u003eRADIUS based user authentication\u003cbr\u003eIEC 62443-4-2 SL1\u003cbr\u003eprotection functions    Overvoltage\u003cbr\u003eUndervoltage\u003cbr\u003ePositive sequence undervoltage 27P\u003cbr\u003eEarth fault overvoltage 59N\u003cbr\u003eUnderfrequency 81\/81N\u003cbr\u003eRate of change of frequency 81R\u003cbr\u003eSynchro-check\u003cbr\u003eBreaker failure 50BF\u003cbr\u003eLockout relay\u003cbr\u003eVT supervision\u003cbr\u003eProgrammable stages\u003cbr\u003eProgrammable curve\u003cbr\u003emeasurement functions    Voltage 3-phase\u003cbr\u003eVoltage residual\u003cbr\u003eVoltage zero sequence\u003cbr\u003eVoltage positive sequence\u003cbr\u003eVoltage negative sequence\u003cbr\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003cbr\u003ePhasor diagram of currents or voltages\u003cbr\u003econtrol functions    Switchgear control and monitoring\u003cbr\u003eProgrammable switchgear interlocking\u003cbr\u003eLocal\/remote control\u003cbr\u003econtrollable switchgear devices    6 controlled + 2 monitored objects\u003cbr\u003enumber of setting groups    4\u003cbr\u003emonitoring functions    Trip circuit supervision 74\u003cbr\u003eCircuit breaker monitoring\u003cbr\u003eRelay self-monitoring\u003cbr\u003elogs and records    Event recording\u003cbr\u003eDisturbance recording\u003cbr\u003eTripping context\u003cbr\u003eRelay maintenance\u003cbr\u003eSwitchgear diagnosis type    VT supervision ANSI code: 60\u003cbr\u003eTrip circuit supervision ANSI code: 74\u003cbr\u003eConnections - terminals    Screw (digital input\/output)\u003cbr\u003eRing lugs (analog inputs and outputs)\u003cbr\u003eComplementary\u003cbr\u003eSoftware name    ESetup Easergy Pro: virtual simulation test\u003cbr\u003eDisplay type    LCD 192 x 96 pixels\u003cbr\u003eNumber of key    1 customizable\u003cbr\u003eLocal signalling    4 x LED\u003cbr\u003e6 x LED tri-colour programmable\u003cbr\u003eHeight    176 mm\u003cbr\u003eWidth    102 mm\u003cbr\u003eDepth    219 mm\u003cbr\u003eNet weight    2.5 kg\u003cbr\u003eEnvironment\u003cbr\u003eclimatic withstand    Exposure to cold conforming to IEC 60068-2-1\u003cbr\u003eExposure to dry heat conforming to IEC 60068-2-2\u003cbr\u003eExposure to damp heat in service conforming to IEC 60068-2-78\u003cbr\u003eExposure to damp heat in service conforming to IEC 60068-2-30\u003cbr\u003eTemperature variation conforming to IEC 60068-2-14\u003cbr\u003eSalt mist conforming to IEC 60068-2-52\u003cbr\u003eInfluence of corrosion\/gas test 2 conforming to IEC 60068-2-60\u003cbr\u003eInfluence of corrosion\/gas test 4 conforming to IEC 60068-2-60\u003cbr\u003eInfluence of corrosion\/gas test 2 conforming to IEC 60721-3-3\u003cbr\u003eInfluence of corrosion\/gas test 4 conforming to IEC 60721-3-3\u003cbr\u003eMechanical robustness    Vibrations (level: class 2) conforming to IEC 60255-21-1\u003cbr\u003eVibrations conforming to GOST 17516.1\u003cbr\u003eVibrations conforming to IACS E10\u003cbr\u003eShocks (level: class 2) conforming to IEC 60255-21-2\u003cbr\u003eEarthquakes (level: class 2) conforming to IEC 60255-21-3\u003cbr\u003eElectromagnetic compatibility    Emission tests class A conforming to CISPR 11\u003cbr\u003eEmission tests class A conforming to CISPR 32\u003cbr\u003eEmission tests conforming to IACS E10\u003cbr\u003eEMC immunity class 4 conforming to IEC 61000-4-2\u003cbr\u003eEMC immunity class 4 conforming to ANSI C37.90.3\u003cbr\u003eEMC immunity level 3 conforming to IEC 61000-4-3\u003cbr\u003eEMC immunity conforming to ANSI C37.90.2\u003cbr\u003eEMC immunity conforming to GOST 32137\u003cbr\u003eEMC immunity conforming to GOST 30804.4.3\u003cbr\u003eEMC immunity conforming to IACS E10\u003cbr\u003eEMC immunity level 5 conforming to IEC 61000-4-8\u003cbr\u003eEMC immunity level 5 conforming to IEC 61000-4-9\u003cbr\u003eEMC immunity level 5 conforming to IEC 61000-4-10\u003cbr\u003eEMC immunity level 3 conforming to IEC 61000-4-6\u003cbr\u003eEMC immunity level 3 conforming to IEC 61000-4-18\u003cbr\u003eEMC immunity conforming to ANSI C37.90.1\u003cbr\u003eEMC immunity conforming to IEC 61000-4-12\u003cbr\u003eEMC immunity conforming to GOST 30804.4.12\u003cbr\u003eEMC immunity level 4 conforming to IEC 61000-4-16\u003cbr\u003eEMC immunity level 4 conforming to IEC 61000-4-4\u003cbr\u003eEMC immunity level 4 conforming to IEC 61000-4-5\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAmbient air temperature for operation\u003cbr\u003e\u003c\/strong\u003e-40…85 °C ( 16 h )\u003cbr\u003e-40…70 °C ( 96 h )\u003cbr\u003eAmbient air temperature for storage    -40…85 °C\u003cbr\u003eIP degree of protection    IP54 conforming to IEC 60529\u003cbr\u003emaximum operating altitude    2000 m\u003cbr\u003eProtective treatment    Conformal coating conforming to IEC 60068-2-52:Kb\/1\u003cbr\u003eConformal coating conforming to IEC 60068-2-60:Ke\u003cbr\u003eConformal coating conforming to IEC 60721-3-3:3C2\u003cbr\u003eRelative humidity    0…93 % at 40 °C, without condensation, 56 days\u003cbr\u003e93…95 % at 25…55 °C, 6 cycles, 12 + 12 hours\u003cbr\u003ePacking Units\u003cbr\u003eUnit Type of Package 1    PCE\u003cbr\u003eNumber of Units in Package 1    1\u003cbr\u003ePackage 1 Height    30.0 cm\u003cbr\u003ePackage 1 Width    30.0 cm\u003cbr\u003ePackage 1 Length    40.0 cm\u003cbr\u003ePackage 1 Weight    3.0 kg\u003cbr\u003eContractual warranty\u003cbr\u003eWarranty (in months)    24\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":47671841816676,"sku":null,"price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/3791\/7796\/files\/files_14_27643dac-f5b9-4fa3-85e2-d6f9cc0dcc3b.png?v=1767959482"},{"product_id":"powerlogic™-p5f30-48-250v-3ct-2io-4vt-10di-8do","title":"PowerLogic™ P5F30 48-250V 3CT 2Io 4VT 10DI-8DO","description":"\u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003cbr\u003eThe PowerLogic P5 is Schneider Electric's withdrawable protection and control relay for demanding medium voltage distribution applications. This feeder relay offers withdrawable design with backup memory function enabling industry-leading 10 minute recovery time. It provides redundant Ethernet including IEC 61850 as well as plug and play communication modules that can evolve with your application. The product embeds latest cybersecurity functionality to help prevent intentional mis-use and cyber-threats. PowerLogic P5 offers safety, security, and connectivity built on more than 100 years of experience in protection relays. The PowerLogic P5 protection relay can be applied to all types of MV distribution networks. It can be supplied with 48 to 250 VDC and 100 to 230 VAC. It works with conventional CTs\/VTs. 3 phase current inputs, 1 standard neutral current input, 1 sensitive neutral current input and 4 voltage inputs. It offers 10 digital inputs and 8 digital outputs and no communications. Communication modules can be added any time. The product dimensions are 180 mm in height (7.09 in), 152,4 mm in width (6.00 in) and 224 mm in depth 8.82 in) for a net weight of 3.5 kg (7.7 lbs). PowerLogic P5 is compliant with EN60255-26, EN 60255-27 standard and with UL Standard. It provides Marine certification. This product can be flush mounted on the panel or in the rack. Flush mounting frames to ensure IP54 are available. Fixing and wiring accessories are included. Plug and play communication modules: Ethernet RSTP RJ45 (REL51038), Ethernet RSTP FO (REL51039), Ethernet HSR\/PRP FO (REL51033). And also 2nd Ethernet RSTP RJ45 (REL51042), RS485 serial RJ45 (REL51036), RS485 serial FO (REL51040), Extension\/backup memory (REL51034). IP54 flush mounting frame (REL51052), 8 temperature sensor module (59641), IRIG-B module (REL51045). connection cords (59660, 59661, 59662). eSetup Easergy Pro software with virtual injection testing and EcoStruxure Power Device app for simpler and safer operation and maintenance. Included with functions as per the datasheet below. For other configurations with additional functions and options, Please select via Product Selector.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003cbr\u003eMain\u003cbr\u003eRange of product    PowerLogic P5\u003cbr\u003eProduct or component type    Protection and control relay\u003cbr\u003eRelay application    Feeder - directional over current\u003cbr\u003eproduct reference    P5F30-AACB-GAAAA-BAEA\u003cbr\u003eMounting case size    30TE\u003cbr\u003eDevice mounting    Flush\u003cbr\u003eMounting mode    Withdrawable\u003cbr\u003epower supply    48...250 V DC\u003cbr\u003e100...230 V AC\u003cbr\u003emeasuring inputs    : 1\/5 A CT phase current 3\u003cbr\u003e: 1\/5 A CT residual current 1\u003cbr\u003e: 1 A CT residual current 1\u003cbr\u003e: VT voltage 4\u003cbr\u003eNumber of sensors    0 temperature sensor(s)\u003cbr\u003e0 arc sensor(s)\u003cbr\u003enumber of Digital Inputs (DI)    10\u003cbr\u003enumber of analogue inputs    0\u003cbr\u003enumber of Digital Outputs (DO)    7 DO\u003cbr\u003e1 watchdog\u003cbr\u003enumber of analogue outputs    0\u003cbr\u003ecommunication ports    USB port 2 front\u003cbr\u003ecommunication protocols    -\u003cbr\u003eCybersecurity    Port hardening\u003cbr\u003eFirmware signature\u003cbr\u003eClient IP address filter\u003cbr\u003eSecured communication with assciated tools\u003cbr\u003eSecurity policy management\u003cbr\u003eRole-based access control\u003cbr\u003eSecurity log\u003cbr\u003eLDAP\u003cbr\u003eRADIUS based user authentication\u003cbr\u003eIEC 62443-4-2 SL1\u003cbr\u003eprotection functions    Phase overcurrent 50\/51\u003cbr\u003eDirectional phase overcurrent 67\u003cbr\u003eEarth fault overcurrent 50N\/51N\u003cbr\u003eRestricted earth fault 64REF\u003cbr\u003eDirectional earth fault 67N\u003cbr\u003eTransient earth fault 67NI\u003cbr\u003eNeutral admittance 21YN\u003cbr\u003eEarth fault wattmetric 32N\u003cbr\u003eCapacitor bank unbalance 51C\u003cbr\u003eBroken conductor 46 I2\/I1\u003cbr\u003eCurrent unbalance 46 I2\/I1\u003cbr\u003eCold load pick-up\u003cbr\u003eSwitch ON to fault (SOTF)\u003cbr\u003eH2 detection\u003cbr\u003eH5 detection\u003cbr\u003eBreaker failure 50BF\u003cbr\u003eDirectional active underpower 37P\u003cbr\u003eFault locator 21FL\u003cbr\u003eRecloser 79\u003cbr\u003eNegative sequence overcurrent 46\u003cbr\u003eOvervoltage 59\u003cbr\u003eUndervoltage 27\u003cbr\u003eEarth fault overvoltage 59N\u003cbr\u003eUnderfrequency 81\/81N\u003cbr\u003eRate of change of frequency 81R\u003cbr\u003eSynchro-check 25\u003cbr\u003eLockout relay 86\u003cbr\u003eCT supervision 60\u003cbr\u003eVT supervision 60\u003cbr\u003eProgrammable stages 99\u003cbr\u003eProgrammable logic\u003cbr\u003eProgrammable curve\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003emeasurement functions\u003cbr\u003e\u003c\/strong\u003eCurrent 3-phase\u003cbr\u003eCurrent zero sequence\u003cbr\u003eCurrent positive sequence\u003cbr\u003eCurrent negative sequence\u003cbr\u003eCurrent ratio of negative and positive\u003cbr\u003ePhasor diagram of currents or voltages\u003cbr\u003eCurrent 2nd, 15th harmonics with THD\u003cbr\u003eVoltage 3-phase\u003cbr\u003eVoltage residual\u003cbr\u003eVoltage zero sequence\u003cbr\u003eVoltage positive sequence\u003cbr\u003eVoltage negative sequence\u003cbr\u003eFrequency\u003cbr\u003e\u003cstrong\u003econtrol functions\u003cbr\u003e\u003c\/strong\u003eSwitchgear control and monitoring\u003cbr\u003eProgrammable switchgear interlocking\u003cbr\u003eLocal\/remote control\u003cbr\u003econtrollable switchgear devices    6 controlled + 2 monitored objects\u003cbr\u003enumber of setting groups    4\u003cbr\u003emonitoring functions    Trip circuit supervision 74\u003cbr\u003eCircuit breaker monitoring\u003cbr\u003eRelay self-monitoring\u003cbr\u003elogs and records    Event recording\u003cbr\u003eDisturbance recording\u003cbr\u003eTripping context\u003cbr\u003eRelay maintenance\u003cbr\u003eSwitchgear diagnosis type    CT\/VT supervision ANSI code: 60\u003cbr\u003eTrip circuit supervision ANSI code: 74\u003cbr\u003eConnections - terminals    Screw (digital input\/output)\u003cbr\u003eRing lugs (analog inputs and outputs)\u003cbr\u003eComplementary\u003cbr\u003eSoftware name    ESetup Easergy Pro: virtual simulation test\u003cbr\u003eDisplay type    Colour LCD 480 x 272 pixels\u003cbr\u003eNumber of key    7 customizable\u003cbr\u003eLocal signalling    4 x LED\u003cbr\u003e10 x LED tri-colour programmable\u003cbr\u003eHeight    176 mm\u003cbr\u003eWidth    152 mm\u003cbr\u003eDepth    219 mm\u003cbr\u003eNet weight    3.5 kg\u003cbr\u003eEnvironment\u003cbr\u003e\u003cstrong\u003eclimatic withstand\u003cbr\u003e\u003c\/strong\u003eExposure to cold conforming to IEC 60068-2-1\u003cbr\u003eExposure to dry heat conforming to IEC 60068-2-2\u003cbr\u003eExposure to damp heat in service conforming to IEC 60068-2-78\u003cbr\u003eExposure to damp heat in service conforming to IEC 60068-2-30\u003cbr\u003eTemperature variation conforming to IEC 60068-2-14\u003cbr\u003eSalt mist conforming to IEC 60068-2-52\u003cbr\u003eInfluence of corrosion\/gas test 2 conforming to IEC 60068-2-60\u003cbr\u003eInfluence of corrosion\/gas test 4 conforming to IEC 60068-2-60\u003cbr\u003eInfluence of corrosion\/gas test 2 conforming to IEC 60721-3-3\u003cbr\u003eInfluence of corrosion\/gas test 4 conforming to IEC 60721-3-3\u003cbr\u003eMechanical robustness    Vibrations (level: class 2) conforming to IEC 60255-21-1\u003cbr\u003eVibrations conforming to GOST 17516.1\u003cbr\u003eVibrations conforming to IACS E10\u003cbr\u003eShocks (level: class 2) conforming to IEC 60255-21-2\u003cbr\u003eEarthquakes (level: class 2) conforming to IEC 60255-21-3\u003cbr\u003e\u003cstrong\u003eElectromagnetic compatibility\u003cbr\u003e\u003c\/strong\u003eEmission tests class A conforming to CISPR 11\u003cbr\u003eEmission tests class A conforming to CISPR 32\u003cbr\u003eEmission tests conforming to IACS E10\u003cbr\u003eEMC immunity class 4 conforming to IEC 61000-4-2\u003cbr\u003eEMC immunity class 4 conforming to ANSI C37.90.3\u003cbr\u003eEMC immunity level 3 conforming to IEC 61000-4-3\u003cbr\u003eEMC immunity conforming to ANSI C37.90.2\u003cbr\u003eEMC immunity conforming to GOST 32137\u003cbr\u003eEMC immunity conforming to GOST 30804.4.3\u003cbr\u003eEMC immunity conforming to IACS E10\u003cbr\u003eEMC immunity level 5 conforming to IEC 61000-4-8\u003cbr\u003eEMC immunity level 5 conforming to IEC 61000-4-9\u003cbr\u003eEMC immunity level 5 conforming to IEC 61000-4-10\u003cbr\u003eEMC immunity level 3 conforming to IEC 61000-4-6\u003cbr\u003eEMC immunity level 3 conforming to IEC 61000-4-18\u003cbr\u003eEMC immunity conforming to ANSI C37.90.1\u003cbr\u003eEMC immunity conforming to IEC 61000-4-12\u003cbr\u003eEMC immunity conforming to GOST 30804.4.12\u003cbr\u003eEMC immunity level 4 conforming to IEC 61000-4-16\u003cbr\u003eEMC immunity level 4 conforming to IEC 61000-4-4\u003cbr\u003eEMC immunity level 4 conforming to IEC 61000-4-5\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAmbient air temperature for operation\u003c\/strong\u003e \u003cbr\u003e-40…85 °C ( 16 h )\u003cbr\u003e-40…70 °C ( 96 h )\u003cbr\u003eAmbient air temperature for storage    -40…85 °C\u003cbr\u003eIP degree of protection    IP54 conforming to IEC 60529\u003cbr\u003emaximum operating altitude    2000 m\u003cbr\u003eProtective treatment    Conformal coating conforming to IEC 60068-2-52:Kb\/1\u003cbr\u003eConformal coating conforming to IEC 60068-2-60:Ke\u003cbr\u003eConformal coating conforming to IEC 60721-3-3:3C2\u003cbr\u003eRelative humidity    0…93 % at 40 °C, without condensation, 56 days\u003cbr\u003e93…95 % at 25…55 °C, 6 cycles, 12 + 12 hours\u003cbr\u003ePacking Units\u003cbr\u003eUnit Type of Package 1    PCE\u003cbr\u003eNumber of Units in Package 1    1\u003cbr\u003ePackage 1 Height    30.0 cm\u003cbr\u003ePackage 1 Width    30.0 cm\u003cbr\u003ePackage 1 Length    35.0 cm\u003cbr\u003ePackage 1 Weight    4.5 kg\u003cbr\u003eContractual warranty\u003cbr\u003eWarranty (in months)    24\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":47671884054628,"sku":null,"price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/3791\/7796\/files\/files_15_8609a5b2-e4d9-4c53-9974-3df8b8831937.png?v=1767960621"},{"product_id":"powerlogic™-p5f30-48-250v-3ct-1csh-4vt-10di-8do","title":"PowerLogic™ P5F30 48-250V 3CT 1CSH 4VT 10DI-8DO","description":"\u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003cbr\u003eThe PowerLogic P5 is Schneider Electric's withdrawable protection and control relay for demanding medium voltage distribution applications. This feeder relay offers withdrawable design with backup memory function enabling industry-leading 10 minute recovery time. It provides redundant Ethernet including IEC 61850 as well as plug and play communication modules that can evolve with your application. The product embeds latest cybersecurity functionality to help prevent intentional mis-use and cyber-threats. PowerLogic P5 offers safety, security, and connectivity built on more than 100 years of experience in protection relays. The PowerLogic P5 protection relay can be applied to all types of MV distribution networks. It can be supplied with 48 to 250 VDC and 100 to 230 VAC. It works with conventional CTs\/VTs. 3 phase current inputs, 1 Schneider Electric specific CSH neutral current input and 4 voltage inputs. It offers 10 digital inputs and 8 digital outputs and no communications. Communication modules can be added any time. The product dimensions are 180 mm in height (7.09 in), 152,4 mm in width (6.00 in) and 224 mm in depth 8.82 in) for a net weight of 3.5 kg (7.7 lbs). PowerLogic P5 is compliant with EN 60255-26, EN 60255-27 standard and with UL Standard. It provides Marine certification. This product can be flush mounted on the panel or in the rack. Flush mounting frames to ensure IP54 are available. Fixing and wiring accessories are included. Plug and play communication modules: Ethernet RSTP RJ45 (REL51038), Ethernet RSTP FO (REL51039), Ethernet HSR\/PRP FO (REL51033). And also 2nd Ethernet RSTP RJ45 (REL51042), RS485 serial RJ45 (REL51036), RS485 serial FO (REL51040), Extension\/backup memory (REL51034). IP54 flush mounting frame (REL51052), CSH core-balance CTs (59635, 59636, 59637), 8 temperature sensor module (59641), IRIG-B module (REL51045). connection cords (59660, 59661, 59662). eSetup Easergy Pro software with virtual injection testing and EcoStruxure Power Device app for simpler and safer operation and maintenance. Included with functions as per the datasheet below. For other configurations with additional functions and options, Please select via Product Selector.\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003cbr\u003eMain\u003cbr\u003eRange of product    PowerLogic P5\u003cbr\u003eProduct or component type    Protection and control relay\u003cbr\u003eRelay application    Feeder - directional over current\u003cbr\u003eproduct reference    P5F30-AACB-HAAAA-BAEA\u003cbr\u003eMounting case size    30TE\u003cbr\u003eDevice mounting    Flush\u003cbr\u003eMounting mode    Withdrawable\u003cbr\u003epower supply    48...250 V DC\u003cbr\u003e100...230 V AC\u003cbr\u003emeasuring inputs    : 1\/5 A CT phase current 3\u003cbr\u003e: CSH residual current 1\u003cbr\u003e: VT voltage 4\u003cbr\u003eNumber of sensors    0 temperature sensor(s)\u003cbr\u003e0 arc sensor(s)\u003cbr\u003enumber of Digital Inputs (DI)    10\u003cbr\u003enumber of analogue inputs    0\u003cbr\u003enumber of Digital Outputs (DO)    7 DO\u003cbr\u003e1 watchdog\u003cbr\u003enumber of analogue outputs    0\u003cbr\u003ecommunication ports    USB port 2 front\u003cbr\u003ecommunication protocols    -\u003cbr\u003eCybersecurity    Port hardening\u003cbr\u003eFirmware signature\u003cbr\u003eClient IP address filter\u003cbr\u003eSecured communication with assciated tools\u003cbr\u003eSecurity policy management\u003cbr\u003eRole-based access control\u003cbr\u003eSecurity log\u003cbr\u003eLDAP\u003cbr\u003eRADIUS based user authentication\u003cbr\u003eIEC 62443-4-2 SL1\u003cbr\u003e\u003cstrong\u003eprotection functions\u003cbr\u003e\u003c\/strong\u003ePhase overcurrent 50\/51\u003cbr\u003eDirectional phase overcurrent 67\u003cbr\u003eEarth fault overcurrent 50N\/51N\u003cbr\u003eDirectional earth fault 67N\u003cbr\u003eTransient earth fault 67NI\u003cbr\u003eNeutral admittance 21YN\u003cbr\u003eEarth fault wattmetric 32N\u003cbr\u003eCapacitor bank unbalance 51C\u003cbr\u003eBroken conductor 46 I2\/I1\u003cbr\u003eCurrent unbalance 46 I2\/I1\u003cbr\u003eCold load pick-up\u003cbr\u003eSwitch ON to fault (SOTF)\u003cbr\u003eH2 detection\u003cbr\u003eH5 detection\u003cbr\u003eBreaker failure 50BF\u003cbr\u003eDirectional active underpower 37P\u003cbr\u003eFault locator 21FL\u003cbr\u003eRecloser 79\u003cbr\u003eNegative sequence overcurrent 46\u003cbr\u003eOvervoltage 59\u003cbr\u003eUndervoltage 27\u003cbr\u003eEarth fault overvoltage 59N\u003cbr\u003eUnderfrequency 81\/81N\u003cbr\u003eRate of change of frequency 81R\u003cbr\u003eSynchro-check 25\u003cbr\u003eLockout relay 86\u003cbr\u003eCT supervision 60\u003cbr\u003eVT supervision 60\u003cbr\u003eProgrammable stages 99\u003cbr\u003eProgrammable logic\u003cbr\u003eProgrammable curve\u003cbr\u003e\u003cstrong\u003emeasurement functions\u003cbr\u003e\u003c\/strong\u003eCurrent 3-phase\u003cbr\u003eCurrent zero sequence\u003cbr\u003eCurrent positive sequence\u003cbr\u003eCurrent negative sequence\u003cbr\u003eCurrent ratio of negative and positive\u003cbr\u003ePhasor diagram of currents or voltages\u003cbr\u003eCurrent 2nd, 15th harmonics with THD\u003cbr\u003eVoltage 3-phase\u003cbr\u003eVoltage residual\u003cbr\u003eVoltage zero sequence\u003cbr\u003eVoltage positive sequence\u003cbr\u003eVoltage negative sequence\u003cbr\u003eFrequency\u003cbr\u003e\u003cstrong\u003econtrol functions\u003cbr\u003e\u003c\/strong\u003eSwitchgear control and monitoring\u003cbr\u003eProgrammable switchgear interlocking\u003cbr\u003eLocal\/remote control\u003cbr\u003econtrollable switchgear devices    6 controlled + 2 monitored objects\u003cbr\u003enumber of setting groups    4\u003cbr\u003emonitoring functions    Trip circuit supervision 74\u003cbr\u003eCircuit breaker monitoring\u003cbr\u003eRelay self-monitoring\u003cbr\u003elogs and records    Event recording\u003cbr\u003eDisturbance recording\u003cbr\u003eTripping context\u003cbr\u003eRelay maintenance\u003cbr\u003eSwitchgear diagnosis type    CT\/VT supervision ANSI code: 60\u003cbr\u003eTrip circuit supervision ANSI code: 74\u003cbr\u003eConnections - terminals    Screw (digital input\/output)\u003cbr\u003eRing lugs (analog inputs and outputs)\u003cbr\u003eComplementary\u003cbr\u003eSoftware name    ESetup Easergy Pro: virtual simulation test\u003cbr\u003eDisplay type    Colour LCD 480 x 272 pixels\u003cbr\u003eNumber of key    7 customizable\u003cbr\u003eLocal signalling    4 x LED\u003cbr\u003e10 x LED tri-colour programmable\u003cbr\u003eHeight    176 mm\u003cbr\u003eWidth    152 mm\u003cbr\u003eDepth    219 mm\u003cbr\u003eNet weight    3.5 kg\u003cbr\u003eEnvironment\u003cbr\u003e\u003cstrong\u003eclimatic withstand\u003cbr\u003e\u003c\/strong\u003eExposure to cold conforming to IEC 60068-2-1\u003cbr\u003eExposure to dry heat conforming to IEC 60068-2-2\u003cbr\u003eExposure to damp heat in service conforming to IEC 60068-2-78\u003cbr\u003eExposure to damp heat in service conforming to IEC 60068-2-30\u003cbr\u003eTemperature variation conforming to IEC 60068-2-14\u003cbr\u003eSalt mist conforming to IEC 60068-2-52\u003cbr\u003eInfluence of corrosion\/gas test 2 conforming to IEC 60068-2-60\u003cbr\u003eInfluence of corrosion\/gas test 4 conforming to IEC 60068-2-60\u003cbr\u003eInfluence of corrosion\/gas test 2 conforming to IEC 60721-3-3\u003cbr\u003eInfluence of corrosion\/gas test 4 conforming to IEC 60721-3-3\u003cbr\u003eMechanical robustness    Vibrations (level: class 2) conforming to IEC 60255-21-1\u003cbr\u003eVibrations conforming to GOST 17516.1\u003cbr\u003eVibrations conforming to IACS E10\u003cbr\u003eShocks (level: class 2) conforming to IEC 60255-21-2\u003cbr\u003eEarthquakes (level: class 2) conforming to IEC 60255-21-3\u003cbr\u003eElectromagnetic compatibility    Emission tests class A conforming to CISPR 11\u003cbr\u003eEmission tests class A conforming to CISPR 32\u003cbr\u003eEmission tests conforming to IACS E10\u003cbr\u003eEMC immunity class 4 conforming to IEC 61000-4-2\u003cbr\u003eEMC immunity class 4 conforming to ANSI C37.90.3\u003cbr\u003eEMC immunity level 3 conforming to IEC 61000-4-3\u003cbr\u003eEMC immunity conforming to ANSI C37.90.2\u003cbr\u003eEMC immunity conforming to GOST 32137\u003cbr\u003eEMC immunity conforming to GOST 30804.4.3\u003cbr\u003eEMC immunity conforming to IACS E10\u003cbr\u003eEMC immunity level 5 conforming to IEC 61000-4-8\u003cbr\u003eEMC immunity level 5 conforming to IEC 61000-4-9\u003cbr\u003eEMC immunity level 5 conforming to IEC 61000-4-10\u003cbr\u003eEMC immunity level 3 conforming to IEC 61000-4-6\u003cbr\u003eEMC immunity level 3 conforming to IEC 61000-4-18\u003cbr\u003eEMC immunity conforming to ANSI C37.90.1\u003cbr\u003eEMC immunity conforming to IEC 61000-4-12\u003cbr\u003eEMC immunity conforming to GOST 30804.4.12\u003cbr\u003eEMC immunity level 4 conforming to IEC 61000-4-16\u003cbr\u003eEMC immunity level 4 conforming to IEC 61000-4-4\u003cbr\u003eEMC immunity level 4 conforming to IEC 61000-4-5\u003cbr\u003eAmbient air temperature for operation    -40…85 °C ( 16 h )\u003cbr\u003e-40…70 °C ( 96 h )\u003cbr\u003eAmbient air temperature for storage    -40…85 °C\u003cbr\u003eIP degree of protection    IP54 conforming to IEC 60529\u003cbr\u003emaximum operating altitude    2000 m\u003cbr\u003eProtective treatment    Conformal coating conforming to IEC 60068-2-52:Kb\/1\u003cbr\u003eConformal coating conforming to IEC 60068-2-60:Ke\u003cbr\u003eConformal coating conforming to IEC 60721-3-3:3C2\u003cbr\u003eRelative humidity    0…93 % at 40 °C, without condensation, 56 days\u003cbr\u003e93…95 % at 25…55 °C, 6 cycles, 12 + 12 hours\u003cbr\u003ePacking Units\u003cbr\u003e\u003cstrong\u003eUnit Type of Package 1\u003cbr\u003e\u003c\/strong\u003ePCE\u003cbr\u003eNumber of Units in Package 1    1\u003cbr\u003ePackage 1 Height    30.0 cm\u003cbr\u003ePackage 1 Width    30.0 cm\u003cbr\u003ePackage 1 Length    35.0 cm\u003cbr\u003ePackage 1 Weight    4.5 kg\u003cbr\u003eContractual warranty\u003cbr\u003eWarranty (in months)    24\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":47671901257828,"sku":null,"price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/3791\/7796\/files\/files_16_f0a2e0de-d634-4ef4-8d79-612c21796301.png?v=1767960949"},{"product_id":"powerlogic™-p5f30-48-250v-3ct-2io-4vt-16di-12do","title":"PowerLogic™ P5F30 48-250V 3CT 2Io 4VT 16DI-12DO","description":"\u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003cbr\u003eThe PowerLogic P5 is Schneider Electric's withdrawable protection and control relay for demanding medium voltage distribution applications. This feeder relay offers withdrawable design with backup memory function enabling industry-leading 10 minute recovery time. It provides redundant Ethernet including IEC 61850 as well as plug and play communication modules that can evolve with your application. The product embeds latest cybersecurity functionality to help prevent intentional mis-use and cyber-threats. PowerLogic P5 offers safety, security, and connectivity built on more than 100 years of experience in protection relays. The PowerLogic P5 protection relay can be applied to all types of MV distribution networks. It can be supplied with 48 to 250 VDC and 100 to 230 VAC. It works with conventional CTs\/VTs. 3 phase current inputs, 1 standard neutral current input, 1 sensitive neutral current input and 4 voltage inputs. It offers 16 digital inputs and 12 digital outputs and no communications. Communication modules can be added any time. The product dimensions are 180 mm in height (7.09 in), 152,4 mm in width (6.00 in) and 224 mm in depth 8.82 in) for a net weight of 3.5 kg (7.7 lbs). PowerLogic P5 is compliant with EN 60255-26, EN 60255-27 standard and with UL Standard. It provides Marine certification. This product can be flush mounted on the panel or in the rack. Flush mounting frames to ensure IP54 are available. Fixing and wiring accessories are included. Plug and play communication modules: Ethernet RSTP RJ45 (REL51038), Ethernet RSTP FO (REL51039), Ethernet HSR\/PRP FO (REL51033). And also 2nd Ethernet RSTP RJ45 (REL51042), RS485 serial RJ45 (REL51036), RS485 serial FO (REL51040), Extension\/backup memory (REL51034). IP54 flush mounting frame (REL51052), 8 temperature sensor module (59641), IRIG-B module (REL51045). connection cords (59660, 59661, 59662). eSetup Easergy Pro software with virtual injection testing and EcoStruxure Power Device app for simpler and safer operation and maintenance. Included with functions as per the datasheet below. For other configurations with additional functions and options, Please select via Product Selector.\u003cbr\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003cbr\u003eMain\u003cbr\u003eRange of product    PowerLogic P5\u003cbr\u003eProduct or component type    Protection and control relay\u003cbr\u003eRelay application    Feeder - directional over current\u003cbr\u003eproduct reference    P5F30-BACB-GAAAA-BAEA\u003cbr\u003eMounting case size    30TE\u003cbr\u003eDevice mounting    Flush\u003cbr\u003eMounting mode    Withdrawable\u003cbr\u003epower supply    48...250 V DC\u003cbr\u003e100...230 V AC\u003cbr\u003emeasuring inputs    : 1\/5 A CT phase current 3\u003cbr\u003e: 1\/5 A CT residual current 1\u003cbr\u003e: 1 A CT residual current 1\u003cbr\u003e: VT voltage 4\u003cbr\u003eNumber of sensors    0 temperature sensor(s)\u003cbr\u003e0 arc sensor(s)\u003cbr\u003enumber of Digital Inputs (DI)    16\u003cbr\u003enumber of analogue inputs    0\u003cbr\u003enumber of Digital Outputs (DO)    11 DO\u003cbr\u003e1 watchdog\u003cbr\u003enumber of analogue outputs    0\u003cbr\u003ecommunication ports    USB port 2 front\u003cbr\u003ecommunication protocols    -\u003cbr\u003eCybersecurity    Port hardening\u003cbr\u003eFirmware signature\u003cbr\u003eClient IP address filter\u003cbr\u003eSecured communication with assciated tools\u003cbr\u003eSecurity policy management\u003cbr\u003eRole-based access control\u003cbr\u003eSecurity log\u003cbr\u003eLDAP\u003cbr\u003eRADIUS based user authentication\u003cbr\u003eIEC 62443-4-2 SL1\u003cbr\u003eprotection functions    Phase overcurrent 50\/51\u003cbr\u003eDirectional phase overcurrent 67\u003cbr\u003eEarth fault overcurrent 50N\/51N\u003cbr\u003eRestricted earth fault 64REF\u003cbr\u003eDirectional earth fault 67N\u003cbr\u003eTransient earth fault 67NI\u003cbr\u003eNeutral admittance 21YN\u003cbr\u003eEarth fault wattmetric 32N\u003cbr\u003eCapacitor bank unbalance 51C\u003cbr\u003eBroken conductor 46 I2\/I1\u003cbr\u003eCurrent unbalance 46 I2\/I1\u003cbr\u003eCold load pick-up\u003cbr\u003eSwitch ON to fault (SOTF)\u003cbr\u003eH2 detection\u003cbr\u003eH5 detection\u003cbr\u003eBreaker failure 50BF\u003cbr\u003eDirectional active underpower 37P\u003cbr\u003eFault locator 21FL\u003cbr\u003eRecloser 79\u003cbr\u003eNegative sequence overcurrent 46\u003cbr\u003eOvervoltage 59\u003cbr\u003eUndervoltage 27\u003cbr\u003eEarth fault overvoltage 59N\u003cbr\u003eUnderfrequency 81\/81N\u003cbr\u003eRate of change of frequency 81R\u003cbr\u003eSynchro-check 25\u003cbr\u003eLockout relay 86\u003cbr\u003eCT supervision 60\u003cbr\u003eVT supervision 60\u003cbr\u003eProgrammable stages 99\u003cbr\u003eProgrammable logic\u003cbr\u003eProgrammable curve\u003cbr\u003emeasurement functions    Current 3-phase\u003cbr\u003eCurrent zero sequence\u003cbr\u003eCurrent positive sequence\u003cbr\u003eCurrent negative sequence\u003cbr\u003eCurrent ratio of negative and positive\u003cbr\u003ePhasor diagram of currents or voltages\u003cbr\u003eCurrent 2nd, 15th harmonics with THD\u003cbr\u003eVoltage 3-phase\u003cbr\u003eVoltage residual\u003cbr\u003eVoltage zero sequence\u003cbr\u003eVoltage positive sequence\u003cbr\u003eVoltage negative sequence\u003cbr\u003eFrequency\u003cbr\u003e\u003cstrong\u003econtrol functions\u003cbr\u003e\u003c\/strong\u003eSwitchgear control and monitoring\u003cbr\u003eProgrammable switchgear interlocking\u003cbr\u003eLocal\/remote control\u003cbr\u003econtrollable switchgear devices    6 controlled + 2 monitored objects\u003cbr\u003enumber of setting groups    4\u003cbr\u003emonitoring functions    Trip circuit supervision 74\u003cbr\u003eCircuit breaker monitoring\u003cbr\u003eRelay self-monitoring\u003cbr\u003elogs and records    Event recording\u003cbr\u003eDisturbance recording\u003cbr\u003eTripping context\u003cbr\u003eRelay maintenance\u003cbr\u003eSwitchgear diagnosis type    CT\/VT supervision ANSI code: 60\u003cbr\u003eTrip circuit supervision ANSI code: 74\u003cbr\u003eConnections - terminals    Screw (digital input\/output)\u003cbr\u003eRing lugs (analog inputs and outputs)\u003cbr\u003eComplementary\u003cbr\u003eSoftware name    ESetup Easergy Pro: virtual simulation test\u003cbr\u003eDisplay type    Colour LCD 480 x 272 pixels\u003cbr\u003eNumber of key    7 customizable\u003cbr\u003eLocal signalling    4 x LED\u003cbr\u003e10 x LED tri-colour programmable\u003cbr\u003eHeight    176 mm\u003cbr\u003eWidth    152 mm\u003cbr\u003eDepth    219 mm\u003cbr\u003eNet weight    3.5 kg\u003cbr\u003eEnvironment\u003cbr\u003e\u003cstrong\u003eclimatic withstand\u003cbr\u003e\u003c\/strong\u003eExposure to cold conforming to IEC 60068-2-1\u003cbr\u003eExposure to dry heat conforming to IEC 60068-2-2\u003cbr\u003eExposure to damp heat in service conforming to IEC 60068-2-78\u003cbr\u003eExposure to damp heat in service conforming to IEC 60068-2-30\u003cbr\u003eTemperature variation conforming to IEC 60068-2-14\u003cbr\u003eSalt mist conforming to IEC 60068-2-52\u003cbr\u003eInfluence of corrosion\/gas test 2 conforming to IEC 60068-2-60\u003cbr\u003eInfluence of corrosion\/gas test 4 conforming to IEC 60068-2-60\u003cbr\u003eInfluence of corrosion\/gas test 2 conforming to IEC 60721-3-3\u003cbr\u003eInfluence of corrosion\/gas test 4 conforming to IEC 60721-3-3\u003cbr\u003eMechanical robustness    Vibrations (level: class 2) conforming to IEC 60255-21-1\u003cbr\u003eVibrations conforming to GOST 17516.1\u003cbr\u003eVibrations conforming to IACS E10\u003cbr\u003eShocks (level: class 2) conforming to IEC 60255-21-2\u003cbr\u003eEarthquakes (level: class 2) conforming to IEC 60255-21-3\u003cbr\u003eElectromagnetic compatibility    Emission tests class A conforming to CISPR 11\u003cbr\u003eEmission tests class A conforming to CISPR 32\u003cbr\u003eEmission tests conforming to IACS E10\u003cbr\u003eEMC immunity class 4 conforming to IEC 61000-4-2\u003cbr\u003eEMC immunity class 4 conforming to ANSI C37.90.3\u003cbr\u003eEMC immunity level 3 conforming to IEC 61000-4-3\u003cbr\u003eEMC immunity conforming to ANSI C37.90.2\u003cbr\u003eEMC immunity conforming to GOST 32137\u003cbr\u003eEMC immunity conforming to GOST 30804.4.3\u003cbr\u003eEMC immunity conforming to IACS E10\u003cbr\u003eEMC immunity level 5 conforming to IEC 61000-4-8\u003cbr\u003eEMC immunity level 5 conforming to IEC 61000-4-9\u003cbr\u003eEMC immunity level 5 conforming to IEC 61000-4-10\u003cbr\u003eEMC immunity level 3 conforming to IEC 61000-4-6\u003cbr\u003eEMC immunity level 3 conforming to IEC 61000-4-18\u003cbr\u003eEMC immunity conforming to ANSI C37.90.1\u003cbr\u003eEMC immunity conforming to IEC 61000-4-12\u003cbr\u003eEMC immunity conforming to GOST 30804.4.12\u003cbr\u003eEMC immunity level 4 conforming to IEC 61000-4-16\u003cbr\u003eEMC immunity level 4 conforming to IEC 61000-4-4\u003cbr\u003eEMC immunity level 4 conforming to IEC 61000-4-5\u003cbr\u003eAmbient air temperature for operation    -40…85 °C ( 16 h )\u003cbr\u003e-40…70 °C ( 96 h )\u003cbr\u003eAmbient air temperature for storage    -40…85 °C\u003cbr\u003eIP degree of protection    IP54 conforming to IEC 60529\u003cbr\u003emaximum operating altitude    2000 m\u003cbr\u003eProtective treatment    Conformal coating conforming to IEC 60068-2-52:Kb\/1\u003cbr\u003eConformal coating conforming to IEC 60068-2-60:Ke\u003cbr\u003eConformal coating conforming to IEC 60721-3-3:3C2\u003cbr\u003eRelative humidity    0…93 % at 40 °C, without condensation, 56 days\u003cbr\u003e93…95 % at 25…55 °C, 6 cycles, 12 + 12 hours\u003cbr\u003ePacking Units\u003cbr\u003eUnit Type of Package 1    PCE\u003cbr\u003eNumber of Units in Package 1    1\u003cbr\u003ePackage 1 Height    30.0 cm\u003cbr\u003ePackage 1 Width    30.0 cm\u003cbr\u003ePackage 1 Length    35.0 cm\u003cbr\u003ePackage 1 Weight    4.5 kg\u003cbr\u003eContractual warranty\u003cbr\u003eWarranty (in months)    24\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":47671909974116,"sku":null,"price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/3791\/7796\/files\/files_17_2710b3b9-5021-4800-9598-88c798856f2f.png?v=1767961214"},{"product_id":"powerlogic™-p5f30-48-250v-3lpct-1csh-4lpvt-16di-12do","title":"PowerLogic™ P5F30 48-250V 3LPCT 1CSH 4LPVT 16DI-12DO","description":"\u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003cbr\u003eThe PowerLogic P5 is Schneider Electric's withdrawable protection and control relay for demanding medium voltage distribution applications. This feeder relay offers withdrawable design with backup memory function enabling industry-leading 10 minute recovery time. It provides redundant Ethernet including IEC 61850 as well as plug and play communication modules that can evolve with your application. The product embeds latest cybersecurity functionality to help prevent intentional mis-use and cyber-threats. PowerLogic P5 offers safety, security, and connectivity built on more than 100 years of experience in protection relays. The PowerLogic P5 protection relay can be applied to all types of MV distribution networks. It can be supplied with 48 to 250 VDC and 100 to 230 VAC. It works with low power instrument transformers. 3 LPCT inputs, 1 Schneider Electric specific CSH neutral current input and 4 LPVT inputs. It offers 16 digital inputs and 12 digital outputs and no communications. Communication modules can be added any time. The product dimensions are 180 mm in height (7.09 in), 152,4 mm in width (6.00 in) and 224 mm in depth 8.82 in) for a net weight of 3.5 kg (7.7 lbs). PowerLogic P5 is compliant with EN 60255-26, EN 60255-27 standard and with UL Standard. It provides Marine certification. This product can be flush mounted on the panel or in the rack. Flush mounting frames to ensure IP54 are available. Fixing and wiring accessories are included. Plug and play communication modules: Ethernet RSTP RJ45 (REL51038), Ethernet RSTP FO (REL51039), Ethernet HSR\/PRP FO (REL51033). And also 2nd Ethernet RSTP RJ45 (REL51042), RS485 serial RJ45 (REL51036), RS485 serial FO (REL51040), Extension\/backup memory (REL51034). IP54 flush mounting frame (REL51052), CSH core-balance CTs (59635, 59636, 59637), 8 temperature sensor module (59641), IRIG-B module (REL51045). connection cords (59660, 59661, 59662), LPVT hub (EMS59573), VT adapter (EMS59572). eSetup Easergy Pro software with virtual injection testing and EcoStruxure Power Device app for simpler and safer operation and maintenance. Included with functions as per the datasheet below. For other configurations with additional functions and options, Please select via Product Selector.\u003cbr\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003cbr\u003eMain\u003cbr\u003eRange of product    PowerLogic P5\u003cbr\u003eProduct or component type    Protection and control relay\u003cbr\u003eRelay application    Feeder - directional over current\u003cbr\u003eproduct reference    P5F30-BACB-IAAAA-BAEA\u003cbr\u003eMounting case size    30TE\u003cbr\u003eDevice mounting    Flush\u003cbr\u003eMounting mode    Withdrawable\u003cbr\u003epower supply    48...250 V DC\u003cbr\u003e100...230 V AC\u003cbr\u003emeasuring inputs    : LPCT phase current 3\u003cbr\u003e: CSH residual current 1\u003cbr\u003e: LPVT voltage 4\u003cbr\u003eNumber of sensors    0 temperature sensor(s)\u003cbr\u003e0 arc sensor(s)\u003cbr\u003enumber of Digital Inputs (DI)    16\u003cbr\u003enumber of analogue inputs    0\u003cbr\u003enumber of Digital Outputs (DO)    11 DO\u003cbr\u003e1 watchdog\u003cbr\u003enumber of analogue outputs    0\u003cbr\u003ecommunication ports    USB port 2 front\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":47671924195428,"sku":null,"price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/3791\/7796\/files\/files_18_76806c13-b282-4d9b-90b2-56b6975d9cde.png?v=1767961424"},{"product_id":"powerlogic™-p5m30-48-250v-3ct-2io-4vt-10di-8do","title":"PowerLogic™ P5M30 48-250V 3CT 2Io 4VT 10DI-8DO","description":"\u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003cbr\u003eThe PowerLogic P5 is Schneider Electric's withdrawable protection and control relay for demanding medium voltage distribution applications. This motor relay offers withdrawable design with backup memory function enabling industry-leading 10 minute recovery time. It provides redundant Ethernet including IEC 61850 as well as plug and play communication modules that can evolve with your application. The product embeds latest cybersecurity functionality to help prevent intentional mis-use and cyber-threats. PowerLogic P5 offers safety, security, and connectivity built on more than 100 years of experience in protection relays. The PowerLogic P5 protection relay can be applied to all types of MV distribution networks. It can be supplied with 48 to 250 VDC and 100 to 230 VAC. It works with conventional CTs\/VTs. 3 phase current inputs, 1 standard neutral current input, 1 sensitive neutral current input and 4 voltage inputs. It offers 10 digital inputs and 8 digital outputs and no communications. Communication modules can be added any time. The product dimensions are 180 mm in height (7.09 in), 152,4 mm in width (6.00 in) and 224 mm in depth 8.82 in) for a net weight of 3.5 kg (7.7 lbs). PowerLogic P5 is compliant with EN 60255-26, EN 60255-27 standard and with UL Standard. It provides Marine certification. This product can be flush mounted on the panel or in the rack. Flush mounting frames to ensure IP54 are available. Fixing and wiring accessories are included. Plug and play communication modules: Ethernet RSTP RJ45 (REL51038), Ethernet RSTP FO (REL51039), Ethernet HSR\/PRP FO (REL51033). And also 2nd Ethernet RSTP RJ45 (REL51042), RS485 serial RJ45 (REL51036), RS485 serial FO (REL51040), Extension\/backup memory (REL51034). IP54 flush mounting frame (REL51052), 8 temperature sensor module (59641), IRIG-B module (REL51045). connection cords (59660, 59661, 59662). eSetup Easergy Pro software with virtual injection testing and EcoStruxure Power Device app for simpler and safer operation and maintenance. Included with functions as per the datasheet below. For other configurations with additional functions and options, Please select via Product Selector.\u003cbr\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003cbr\u003eMain\u003cbr\u003eRange of product    PowerLogic P5\u003cbr\u003eProduct or component type    Protection and control relay\u003cbr\u003eRelay application    Motor\u003cbr\u003eproduct reference    P5M30-AACB-GAAAA-BAEA\u003cbr\u003eMounting case size    30TE\u003cbr\u003eDevice mounting    Flush\u003cbr\u003eMounting mode    Withdrawable\u003cbr\u003epower supply    48...250 V DC\u003cbr\u003e100...230 V AC\u003cbr\u003emeasuring inputs    : 1\/5 A CT phase current 3\u003cbr\u003e: 1\/5 A CT residual current 1\u003cbr\u003e: 1 A CT residual current 1\u003cbr\u003e: VT voltage 4\u003cbr\u003eNumber of sensors    0 temperature sensor(s)\u003cbr\u003e0 arc sensor(s)\u003cbr\u003enumber of Digital Inputs (DI)    10\u003cbr\u003enumber of analogue inputs    0\u003cbr\u003enumber of Digital Outputs (DO)    7 DO\u003cbr\u003e1 watchdog\u003cbr\u003enumber of analogue outputs    0\u003cbr\u003ecommunication ports    USB port 2 front\u003cbr\u003ecommunication protocols    -\u003cbr\u003eCybersecurity    Port hardening\u003cbr\u003eFirmware signature\u003cbr\u003eClient IP address filter\u003cbr\u003eSecured communication with assciated tools\u003cbr\u003eSecurity policy management\u003cbr\u003eRole-based access control\u003cbr\u003eSecurity log\u003cbr\u003eLDAP\u003cbr\u003eRADIUS based user authentication\u003cbr\u003eIEC 62443-4-2 SL1\u003cbr\u003e\u003cstrong\u003eprotection functions\u003cbr\u003e\u003c\/strong\u003ePhase overcurrent 50\/51\u003cbr\u003eDirectional phase overcurrent 67\u003cbr\u003eEarth fault overcurrent 50N\/51N\u003cbr\u003eRestricted earth fault 64REF\u003cbr\u003eDirectional earth fault 67N\u003cbr\u003eTransient earth fault 67NI\u003cbr\u003eNeutral admittance 21YN\u003cbr\u003eEarth fault wattmetric 32N\u003cbr\u003eBroken conductor 46 I2\/I1\u003cbr\u003eCurrent unbalance 46 I2\/I1\u003cbr\u003eCold load pick-up\u003cbr\u003eSwitch ON to fault (SOTF)\u003cbr\u003eH2 detection\u003cbr\u003eH5 detection\u003cbr\u003eBreaker failure 50BF\u003cbr\u003eDirectional active underpower 37P\u003cbr\u003ePhase undercurrent 37\u003cbr\u003eExcessive starting time, locked rotor 48\/51LR\u003cbr\u003eMotor restart inhibition 66\u003cbr\u003eNegative sequence overcurrent 46\u003cbr\u003eOvervoltage 59\u003cbr\u003eUndervoltage 27\u003cbr\u003ePositive sequence undervoltage 27P\u003cbr\u003eEarth fault overvoltage 59N\u003cbr\u003eUnderfrequency 81\/81N\u003cbr\u003eLockout relay 86\u003cbr\u003eCT supervision 60\u003cbr\u003eVT supervision 60\u003cbr\u003eProgrammable stages 99\u003cbr\u003eProgrammable logic\u003cbr\u003eProgrammable curve\u003cbr\u003e\u003cstrong\u003emeasurement functions\u003cbr\u003e\u003c\/strong\u003eCurrent 3-phase\u003cbr\u003eCurrent zero sequence\u003cbr\u003eCurrent positive sequence\u003cbr\u003eCurrent negative sequence\u003cbr\u003eCurrent ratio of negative and positive\u003cbr\u003ePhasor diagram of currents or voltages\u003cbr\u003eCurrent 2nd, 15th harmonics with THD\u003cbr\u003eVoltage 3-phase\u003cbr\u003eVoltage residual\u003cbr\u003eVoltage zero sequence\u003cbr\u003eVoltage positive sequence\u003cbr\u003eVoltage negative sequence\u003cbr\u003eFrequency\u003cbr\u003econtrol functions    Switchgear control and monitoring\u003cbr\u003eProgrammable switchgear interlocking\u003cbr\u003eLocal\/remote control\u003cbr\u003econtrollable switchgear devices    6 controlled + 2 monitored objects\u003cbr\u003enumber of setting groups    4\u003cbr\u003emonitoring functions    Trip circuit supervision 74\u003cbr\u003eCircuit breaker monitoring\u003cbr\u003eRelay self-monitoring\u003cbr\u003elogs and records    Event recording\u003cbr\u003eDisturbance recording\u003cbr\u003eTripping context\u003cbr\u003eRelay maintenance\u003cbr\u003eSwitchgear diagnosis type    CT\/VT supervision ANSI code: 60\u003cbr\u003eTrip circuit supervision ANSI code: 74\u003cbr\u003eConnections - terminals    Screw (digital input\/output)\u003cbr\u003eRing lugs (analog inputs and outputs)\u003cbr\u003eComplementary\u003cbr\u003eSoftware name    ESetup Easergy Pro: virtual simulation test\u003cbr\u003eDisplay type    Colour LCD 480 x 272 pixels\u003cbr\u003eNumber of key    7 customizable\u003cbr\u003eLocal signalling    4 x LED\u003cbr\u003e10 x LED tri-colour programmable\u003cbr\u003eHeight    176 mm\u003cbr\u003eWidth    152 mm\u003cbr\u003eDepth    219 mm\u003cbr\u003eNet weight    3.5 kg\u003cbr\u003eEnvironment\u003cbr\u003eclimatic withstand    Exposure to cold conforming to IEC 60068-2-1\u003cbr\u003eExposure to dry heat conforming to IEC 60068-2-2\u003cbr\u003eExposure to damp heat in service conforming to IEC 60068-2-78\u003cbr\u003eExposure to damp heat in service conforming to IEC 60068-2-30\u003cbr\u003eTemperature variation conforming to IEC 60068-2-14\u003cbr\u003eSalt mist conforming to IEC 60068-2-52\u003cbr\u003eInfluence of corrosion\/gas test 2 conforming to IEC 60068-2-60\u003cbr\u003eInfluence of corrosion\/gas test 4 conforming to IEC 60068-2-60\u003cbr\u003eInfluence of corrosion\/gas test 2 conforming to IEC 60721-3-3\u003cbr\u003eInfluence of corrosion\/gas test 4 conforming to IEC 60721-3-3\u003cbr\u003eMechanical robustness    Vibrations (level: class 2) conforming to IEC 60255-21-1\u003cbr\u003eVibrations conforming to GOST 17516.1\u003cbr\u003eVibrations conforming to IACS E10\u003cbr\u003eShocks (level: class 2) conforming to IEC 60255-21-2\u003cbr\u003eEarthquakes (level: class 2) conforming to IEC 60255-21-3\u003cbr\u003eElectromagnetic compatibility    Emission tests class A conforming to CISPR 11\u003cbr\u003eEmission tests class A conforming to CISPR 32\u003cbr\u003eEmission tests conforming to IACS E10\u003cbr\u003eEMC immunity class 4 conforming to IEC 61000-4-2\u003cbr\u003eEMC immunity class 4 conforming to ANSI C37.90.3\u003cbr\u003eEMC immunity level 3 conforming to IEC 61000-4-3\u003cbr\u003eEMC immunity conforming to ANSI C37.90.2\u003cbr\u003eEMC immunity conforming to GOST 32137\u003cbr\u003eEMC immunity conforming to GOST 30804.4.3\u003cbr\u003eEMC immunity conforming to IACS E10\u003cbr\u003eEMC immunity level 5 conforming to IEC 61000-4-8\u003cbr\u003eEMC immunity level 5 conforming to IEC 61000-4-9\u003cbr\u003eEMC immunity level 5 conforming to IEC 61000-4-10\u003cbr\u003eEMC immunity level 3 conforming to IEC 61000-4-6\u003cbr\u003eEMC immunity level 3 conforming to IEC 61000-4-18\u003cbr\u003eEMC immunity conforming to ANSI C37.90.1\u003cbr\u003eEMC immunity conforming to IEC 61000-4-12\u003cbr\u003eEMC immunity conforming to GOST 30804.4.12\u003cbr\u003eEMC immunity level 4 conforming to IEC 61000-4-16\u003cbr\u003eEMC immunity level 4 conforming to IEC 61000-4-4\u003cbr\u003eEMC immunity level 4 conforming to IEC 61000-4-5\u003cbr\u003eAmbient air temperature for operation    -40…85 °C ( 16 h )\u003cbr\u003e-40…70 °C ( 96 h )\u003cbr\u003eAmbient air temperature for storage    -40…85 °C\u003cbr\u003eIP degree of protection    IP54 conforming to IEC 60529\u003cbr\u003emaximum operating altitude    2000 m\u003cbr\u003eProtective treatment    Conformal coating conforming to IEC 60068-2-52:Kb\/1\u003cbr\u003eConformal coating conforming to IEC 60068-2-60:Ke\u003cbr\u003eConformal coating conforming to IEC 60721-3-3:3C2\u003cbr\u003eRelative humidity    0…93 % at 40 °C, without condensation, 56 days\u003cbr\u003e93…95 % at 25…55 °C, 6 cycles, 12 + 12 hours\u003cbr\u003e\u003cstrong\u003ePacking Units\u003c\/strong\u003e\u003cbr\u003eUnit Type of Package 1    PCE\u003cbr\u003eNumber of Units in Package 1    1\u003cbr\u003ePackage 1 Height    30.0 cm\u003cbr\u003ePackage 1 Width    30.0 cm\u003cbr\u003ePackage 1 Length    35.0 cm\u003cbr\u003ePackage 1 Weight    4.5 kg\u003cbr\u003eContractual warranty\u003cbr\u003eWarranty (in months)    24\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":47675172716644,"sku":null,"price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/3791\/7796\/files\/files_1fd021a6-f8bb-490d-ad05-1328e5045828.png?v=1768015512"},{"product_id":"powerlogic™-p5m30-48-250v-3ct-1csh-4vt-10di-8do","title":"PowerLogic™ P5M30 48-250V 3CT 1CSH 4VT 10DI-8DO","description":"\u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003cbr\u003eThe PowerLogic P5 is Schneider Electric's withdrawable protection and control relay for demanding medium voltage distribution applications. This motor relay offers withdrawable design with backup memory function enabling industry-leading 10 minute recovery time. It provides redundant Ethernet including IEC 61850 as well as plug and play communication modules that can evolve with your application. The product embeds latest cybersecurity functionality to help prevent intentional mis-use and cyber-threats. PowerLogic P5 offers safety, security, and connectivity built on more than 100 years of experience in protection relays. The PowerLogic P5 protection relay can be applied to all types of MV distribution networks. It can be supplied with 48 to 250 VDC and 100 to 230 VAC. It works with conventional CTs\/VTs. 3 phase current inputs, 1 Schneider Electric specific CSH neutral current input and 4 voltage inputs. It offers 10 digital inputs and 8 digital outputs and no communications. Communication modules can be added any time. The product dimensions are 180 mm in height (7.09 in), 152,4 mm in width (6.00 in) and 224 mm in depth 8.82 in) for a net weight of 3.5 kg (7.7 lbs). PowerLogic P5 is compliant with EN 60255-26, EN 60255-27 standard and with UL Standard. It provides Marine certification. This product can be flush mounted on the panel or in the rack. Flush mounting frames to ensure IP54 are available. Fixing and wiring accessories are included. Plug and play communication modules: Ethernet RSTP RJ45 (REL51038), Ethernet RSTP FO (REL51039), Ethernet HSR\/PRP FO (REL51033). And also 2nd Ethernet RSTP RJ45 (REL51042), RS485 serial RJ45 (REL51036), RS485 serial FO (REL51040), Extension\/backup memory (REL51034). IP54 flush mounting frame (REL51052), CSH core-balance CTs (59635, 59636, 59637), 8 temperature sensor module (59641), IRIG-B module (REL51045). connection cords (59660, 59661, 59662). eSetup Easergy Pro software with virtual injection testing and EcoStruxure Power Device app for simpler and safer operation and maintenance. Included with functions as per the datasheet below. For other configurations with additional functions and options, Please select via Product Selector.\u003cbr\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003cbr\u003eMain\u003cbr\u003eRange of product    PowerLogic P5\u003cbr\u003eProduct or component type    Protection and control relay\u003cbr\u003eRelay application    Motor\u003cbr\u003eproduct reference    P5M30-AACB-HAAAA-BAEA\u003cbr\u003eMounting case size    30TE\u003cbr\u003eDevice mounting    Flush\u003cbr\u003eMounting mode    Withdrawable\u003cbr\u003epower supply    48...250 V DC\u003cbr\u003e100...230 V AC\u003cbr\u003emeasuring inputs    : 1\/5 A CT phase current 3\u003cbr\u003e: CSH residual current 1\u003cbr\u003e: VT voltage 4\u003cbr\u003eNumber of sensors    0 temperature sensor(s)\u003cbr\u003e0 arc sensor(s)\u003cbr\u003enumber of Digital Inputs (DI)    10\u003cbr\u003enumber of analogue inputs    0\u003cbr\u003enumber of Digital Outputs (DO)    7 DO\u003cbr\u003e1 watchdog\u003cbr\u003enumber of analogue outputs    0\u003cbr\u003ecommunication ports    USB port 2 front\u003cbr\u003ecommunication protocols    -\u003cbr\u003eCybersecurity    Port hardening\u003cbr\u003eFirmware signature\u003cbr\u003eClient IP address filter\u003cbr\u003eSecured communication with assciated tools\u003cbr\u003eSecurity policy management\u003cbr\u003eRole-based access control\u003cbr\u003eSecurity log\u003cbr\u003eLDAP\u003cbr\u003eRADIUS based user authentication\u003cbr\u003eIEC 62443-4-2 SL1\u003cbr\u003eprotection functions    Phase overcurrent 50\/51\u003cbr\u003eDirectional phase overcurrent 67\u003cbr\u003eEarth fault overcurrent 50N\/51N\u003cbr\u003eDirectional earth fault 67N\u003cbr\u003eTransient earth fault 67NI\u003cbr\u003eNeutral admittance 21YN\u003cbr\u003eEarth fault wattmetric 32N\u003cbr\u003eBroken conductor 46 I2\/I1\u003cbr\u003eCurrent unbalance 46 I2\/I1\u003cbr\u003eCold load pick-up\u003cbr\u003eSwitch ON to fault (SOTF)\u003cbr\u003eH2 detection\u003cbr\u003eH5 detection\u003cbr\u003eBreaker failure 50BF\u003cbr\u003eDirectional active underpower 37P\u003cbr\u003ePhase undercurrent 37\u003cbr\u003eExcessive starting time, locked rotor 48\/51LR\u003cbr\u003eMotor restart inhibition 66\u003cbr\u003eNegative sequence overcurrent 46\u003cbr\u003eOvervoltage 59\u003cbr\u003eUndervoltage 27\u003cbr\u003ePositive sequence undervoltage 27P\u003cbr\u003eEarth fault overvoltage 59N\u003cbr\u003eUnderfrequency 81\/81N\u003cbr\u003eLockout relay 86\u003cbr\u003eCT supervision 60\u003cbr\u003eVT supervision 60\u003cbr\u003eProgrammable stages 99\u003cbr\u003eProgrammable logic\u003cbr\u003eProgrammable curve\u003cbr\u003emeasurement functions    Current 3-phase\u003cbr\u003eCurrent zero sequence\u003cbr\u003eCurrent positive sequence\u003cbr\u003eCurrent negative sequence\u003cbr\u003eCurrent ratio of negative and positive\u003cbr\u003ePhasor diagram of currents or voltages\u003cbr\u003eCurrent 2nd, 15th harmonics with THD\u003cbr\u003eVoltage 3-phase\u003cbr\u003eVoltage residual\u003cbr\u003eVoltage zero sequence\u003cbr\u003eVoltage positive sequence\u003cbr\u003eVoltage negative sequence\u003cbr\u003eFrequency\u003cbr\u003e\u003cstrong\u003econtrol functions\u003cbr\u003e\u003c\/strong\u003eSwitchgear control and monitoring\u003cbr\u003eProgrammable switchgear interlocking\u003cbr\u003eLocal\/remote control\u003cbr\u003econtrollable switchgear devices    6 controlled + 2 monitored objects\u003cbr\u003enumber of setting groups    4\u003cbr\u003emonitoring functions    Trip circuit supervision 74\u003cbr\u003eCircuit breaker monitoring\u003cbr\u003eRelay self-monitoring\u003cbr\u003elogs and records    Event recording\u003cbr\u003eDisturbance recording\u003cbr\u003eTripping context\u003cbr\u003eRelay maintenance\u003cbr\u003eSwitchgear diagnosis type    CT\/VT supervision ANSI code: 60\u003cbr\u003eTrip circuit supervision ANSI code: 74\u003cbr\u003eConnections - terminals    Screw (digital input\/output)\u003cbr\u003eRing lugs (analog inputs and outputs)\u003cbr\u003eComplementary\u003cbr\u003eSoftware name    ESetup Easergy Pro: virtual simulation test\u003cbr\u003eDisplay type    Colour LCD 480 x 272 pixels\u003cbr\u003eNumber of key    7 customizable\u003cbr\u003eLocal signalling    4 x LED\u003cbr\u003e10 x LED tri-colour programmable\u003cbr\u003eHeight    176 mm\u003cbr\u003eWidth    152 mm\u003cbr\u003eDepth    219 mm\u003cbr\u003eNet weight    3.5 kg\u003cbr\u003eEnvironment\u003cbr\u003e\u003cstrong\u003eclimatic withstand\u003cbr\u003e\u003c\/strong\u003eExposure to cold conforming to IEC 60068-2-1\u003cbr\u003eExposure to dry heat conforming to IEC 60068-2-2\u003cbr\u003eExposure to damp heat in service conforming to IEC 60068-2-78\u003cbr\u003eExposure to damp heat in service conforming to IEC 60068-2-30\u003cbr\u003eTemperature variation conforming to IEC 60068-2-14\u003cbr\u003eSalt mist conforming to IEC 60068-2-52\u003cbr\u003eInfluence of corrosion\/gas test 2 conforming to IEC 60068-2-60\u003cbr\u003eInfluence of corrosion\/gas test 4 conforming to IEC 60068-2-60\u003cbr\u003eInfluence of corrosion\/gas test 2 conforming to IEC 60721-3-3\u003cbr\u003eInfluence of corrosion\/gas test 4 conforming to IEC 60721-3-3\u003cbr\u003eMechanical robustness    Vibrations (level: class 2) conforming to IEC 60255-21-1\u003cbr\u003eVibrations conforming to GOST 17516.1\u003cbr\u003eVibrations conforming to IACS E10\u003cbr\u003eShocks (level: class 2) conforming to IEC 60255-21-2\u003cbr\u003eEarthquakes (level: class 2) conforming to IEC 60255-21-3\u003cbr\u003e\u003cstrong\u003eElectromagnetic compatibility\u003cbr\u003e\u003c\/strong\u003eEmission tests class A conforming to CISPR 11\u003cbr\u003eEmission tests class A conforming to CISPR 32\u003cbr\u003eEmission tests conforming to IACS E10\u003cbr\u003eEMC immunity class 4 conforming to IEC 61000-4-2\u003cbr\u003eEMC immunity class 4 conforming to ANSI C37.90.3\u003cbr\u003eEMC immunity level 3 conforming to IEC 61000-4-3\u003cbr\u003eEMC immunity conforming to ANSI C37.90.2\u003cbr\u003eEMC immunity conforming to GOST 32137\u003cbr\u003eEMC immunity conforming to GOST 30804.4.3\u003cbr\u003eEMC immunity conforming to IACS E10\u003cbr\u003eEMC immunity level 5 conforming to IEC 61000-4-8\u003cbr\u003eEMC immunity level 5 conforming to IEC 61000-4-9\u003cbr\u003eEMC immunity level 5 conforming to IEC 61000-4-10\u003cbr\u003eEMC immunity level 3 conforming to IEC 61000-4-6\u003cbr\u003eEMC immunity level 3 conforming to IEC 61000-4-18\u003cbr\u003eEMC immunity conforming to ANSI C37.90.1\u003cbr\u003eEMC immunity conforming to IEC 61000-4-12\u003cbr\u003eEMC immunity conforming to GOST 30804.4.12\u003cbr\u003eEMC immunity level 4 conforming to IEC 61000-4-16\u003cbr\u003eEMC immunity level 4 conforming to IEC 61000-4-4\u003cbr\u003eEMC immunity level 4 conforming to IEC 61000-4-5\u003cbr\u003eAmbient air temperature for operation    -40…85 °C ( 16 h )\u003cbr\u003e-40…70 °C ( 96 h )\u003cbr\u003eAmbient air temperature for storage    -40…85 °C\u003cbr\u003eIP degree of protection    IP54 conforming to IEC 60529\u003cbr\u003emaximum operating altitude    2000 m\u003cbr\u003eProtective treatment    Conformal coating conforming to IEC 60068-2-52:Kb\/1\u003cbr\u003eConformal coating conforming to IEC 60068-2-60:Ke\u003cbr\u003eConformal coating conforming to IEC 60721-3-3:3C2\u003cbr\u003eRelative humidity    0…93 % at 40 °C, without condensation, 56 days\u003cbr\u003e93…95 % at 25…55 °C, 6 cycles, 12 + 12 hours\u003cbr\u003e\u003cstrong\u003ePacking Units\u003c\/strong\u003e\u003cbr\u003eUnit Type of Package 1    PCE\u003cbr\u003eNumber of Units in Package 1    1\u003cbr\u003ePackage 1 Height    30.0 cm\u003cbr\u003ePackage 1 Width    30.0 cm\u003cbr\u003ePackage 1 Length    35.0 cm\u003cbr\u003ePackage 1 Weight    4.5 kg\u003cbr\u003eContractual warranty\u003cbr\u003eWarranty (in months)    24\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":47675188674660,"sku":null,"price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/3791\/7796\/files\/files_1_b992e5a2-406b-4d21-981e-1a358f40e40b.png?v=1768015813"},{"product_id":"powerlogic™-p5m30-48-250v-3ct-2io-4vt-16di-12do","title":"PowerLogic™ P5M30 48-250V 3CT 2Io 4VT 16DI-12DO","description":"\u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003cbr\u003eThe PowerLogic P5 is Schneider Electric's withdrawable protection and control relay for demanding medium voltage distribution applications. This motor relay offers withdrawable design with backup memory function enabling industry-leading 10 minute recovery time. It provides redundant Ethernet including IEC 61850 as well as plug and play communication modules that can evolve with your application. The product embeds latest cybersecurity functionality to help prevent intentional mis-use and cyber-threats. PowerLogic P5 offers safety, security, and connectivity built on more than 100 years of experience in protection relays. The PowerLogic P5 protection relay can be applied to all types of MV distribution networks. It can be supplied with 48 to 250 VDC and 100 to 230 VAC. It works with conventional CTs\/VTs. 3 phase current inputs, 1 standard neutral current input, 1 sensitive neutral current input and 4 voltage inputs. It offers 16 digital inputs and 12 digital outputs and no communications. Communication modules can be added any time. The product dimensions are 180 mm in height (7.09 in), 152,4 mm in width (6.00 in) and 224 mm in depth 8.82 in) for a net weight of 3.5 kg (7.7 lbs). PowerLogic P5 is compliant with EN 60255-26, EN 60255-27 standard and with UL Standard. It provides Marine certification. This product can be flush mounted on the panel or in the rack. Flush mounting frames to ensure IP54 are available. Fixing and wiring accessories are included. Plug and play communication modules: Ethernet RSTP RJ45 (REL51038), Ethernet RSTP FO (REL51039), Ethernet HSR\/PRP FO (REL51033). And also 2nd Ethernet RSTP RJ45 (REL51042), RS485 serial RJ45 (REL51036), RS485 serial FO (REL51040), Extension\/backup memory (REL51034). IP54 flush mounting frame (REL51052), 8 temperature sensor module (59641), IRIG-B module (REL51045). connection cords (59660, 59661, 59662). eSetup Easergy Pro software with virtual injection testing and EcoStruxure Power Device app for simpler and safer operation and maintenance. Included with functions as per the datasheet below. For other configurations with additional functions and options, Please select via Product Selector.\u003cbr\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003cbr\u003eMain\u003cbr\u003eRange of product    PowerLogic P5\u003cbr\u003eProduct or component type    Protection and control relay\u003cbr\u003eRelay application    Motor\u003cbr\u003eproduct reference    P5M30-BACB-GAAAA-BAEA\u003cbr\u003eMounting case size    30TE\u003cbr\u003eDevice mounting    Flush\u003cbr\u003eMounting mode    Withdrawable\u003cbr\u003epower supply    48...250 V DC\u003cbr\u003e100...230 V AC\u003cbr\u003emeasuring inputs    : 1\/5 A CT phase current 3\u003cbr\u003e: 1\/5 A CT residual current 1\u003cbr\u003e: 1 A CT residual current 1\u003cbr\u003e: VT voltage 4\u003cbr\u003eNumber of sensors    0 temperature sensor(s)\u003cbr\u003e0 arc sensor(s)\u003cbr\u003enumber of Digital Inputs (DI)    16\u003cbr\u003enumber of analogue inputs    0\u003cbr\u003enumber of Digital Outputs (DO)    11 DO\u003cbr\u003e1 watchdog\u003cbr\u003enumber of analogue outputs    0\u003cbr\u003ecommunication ports    USB port 2 front\u003cbr\u003ecommunication protocols    -\u003cbr\u003eCybersecurity    Port hardening\u003cbr\u003eFirmware signature\u003cbr\u003eClient IP address filter\u003cbr\u003eSecured communication with assciated tools\u003cbr\u003eSecurity policy management\u003cbr\u003eRole-based access control\u003cbr\u003eSecurity log\u003cbr\u003eLDAP\u003cbr\u003eRADIUS based user authentication\u003cbr\u003eIEC 62443-4-2 SL1\u003cbr\u003e\u003cstrong\u003eprotection functions\u003cbr\u003e\u003c\/strong\u003ePhase overcurrent 50\/51\u003cbr\u003eDirectional phase overcurrent 67\u003cbr\u003eEarth fault overcurrent 50N\/51N\u003cbr\u003eRestricted earth fault 64REF\u003cbr\u003eDirectional earth fault 67N\u003cbr\u003eTransient earth fault 67NI\u003cbr\u003eNeutral admittance 21YN\u003cbr\u003eEarth fault wattmetric 32N\u003cbr\u003eBroken conductor 46 I2\/I1\u003cbr\u003eCurrent unbalance 46 I2\/I1\u003cbr\u003eCold load pick-up\u003cbr\u003eSwitch ON to fault (SOTF)\u003cbr\u003eH2 detection\u003cbr\u003eH5 detection\u003cbr\u003eBreaker failure 50BF\u003cbr\u003eDirectional active underpower 37P\u003cbr\u003ePhase undercurrent 37\u003cbr\u003eExcessive starting time, locked rotor 48\/51LR\u003cbr\u003eMotor restart inhibition 66\u003cbr\u003eNegative sequence overcurrent 46\u003cbr\u003eOvervoltage 59\u003cbr\u003eUndervoltage 27\u003cbr\u003ePositive sequence undervoltage 27P\u003cbr\u003eEarth fault overvoltage 59N\u003cbr\u003eUnderfrequency 81\/81N\u003cbr\u003eLockout relay 86\u003cbr\u003eCT supervision 60\u003cbr\u003eVT supervision 60\u003cbr\u003eProgrammable stages 99\u003cbr\u003eProgrammable logic\u003cbr\u003eProgrammable curve\u003cbr\u003emeasurement functions    Current 3-phase\u003cbr\u003eCurrent zero sequence\u003cbr\u003eCurrent positive sequence\u003cbr\u003eCurrent negative sequence\u003cbr\u003eCurrent ratio of negative and positive\u003cbr\u003ePhasor diagram of currents or voltages\u003cbr\u003eCurrent 2nd, 15th harmonics with THD\u003cbr\u003eVoltage 3-phase\u003cbr\u003eVoltage residual\u003cbr\u003eVoltage zero sequence\u003cbr\u003eVoltage positive sequence\u003cbr\u003eVoltage negative sequence\u003cbr\u003eFrequency\u003cbr\u003e\u003cstrong\u003econtrol functions\u003cbr\u003e\u003c\/strong\u003eSwitchgear control and monitoring\u003cbr\u003eProgrammable switchgear interlocking\u003cbr\u003eLocal\/remote control\u003cbr\u003econtrollable switchgear devices    6 controlled + 2 monitored objects\u003cbr\u003enumber of setting groups    4\u003cbr\u003emonitoring functions    Trip circuit supervision 74\u003cbr\u003eCircuit breaker monitoring\u003cbr\u003eRelay self-monitoring\u003cbr\u003elogs and records    Event recording\u003cbr\u003eDisturbance recording\u003cbr\u003eTripping context\u003cbr\u003eRelay maintenance\u003cbr\u003eSwitchgear diagnosis type    CT\/VT supervision ANSI code: 60\u003cbr\u003eTrip circuit supervision ANSI code: 74\u003cbr\u003eConnections - terminals    Screw (digital input\/output)\u003cbr\u003eRing lugs (analog inputs and outputs)\u003cbr\u003eComplementary\u003cbr\u003eSoftware name    ESetup Easergy Pro: virtual simulation test\u003cbr\u003eDisplay type    Colour LCD 480 x 272 pixels\u003cbr\u003eNumber of key    7 customizable\u003cbr\u003eLocal signalling    4 x LED\u003cbr\u003e10 x LED tri-colour programmable\u003cbr\u003eHeight    176 mm\u003cbr\u003eWidth    152 mm\u003cbr\u003eDepth    219 mm\u003cbr\u003eNet weight    3.5 kg\u003cbr\u003eEnvironment\u003cbr\u003e\u003cstrong\u003eclimatic withstand\u003cbr\u003e\u003c\/strong\u003eExposure to cold conforming to IEC 60068-2-1\u003cbr\u003eExposure to dry heat conforming to IEC 60068-2-2\u003cbr\u003eExposure to damp heat in service conforming to IEC 60068-2-78\u003cbr\u003eExposure to damp heat in service conforming to IEC 60068-2-30\u003cbr\u003eTemperature variation conforming to IEC 60068-2-14\u003cbr\u003eSalt mist conforming to IEC 60068-2-52\u003cbr\u003eInfluence of corrosion\/gas test 2 conforming to IEC 60068-2-60\u003cbr\u003eInfluence of corrosion\/gas test 4 conforming to IEC 60068-2-60\u003cbr\u003eInfluence of corrosion\/gas test 2 conforming to IEC 60721-3-3\u003cbr\u003eInfluence of corrosion\/gas test 4 conforming to IEC 60721-3-3\u003cbr\u003eMechanical robustness    Vibrations (level: class 2) conforming to IEC 60255-21-1\u003cbr\u003eVibrations conforming to GOST 17516.1\u003cbr\u003eVibrations conforming to IACS E10\u003cbr\u003eShocks (level: class 2) conforming to IEC 60255-21-2\u003cbr\u003eEarthquakes (level: class 2) conforming to IEC 60255-21-3\u003cbr\u003e\u003cstrong\u003eElectromagnetic compatibility\u003cbr\u003e\u003c\/strong\u003eEmission tests class A conforming to CISPR 11\u003cbr\u003eEmission tests class A conforming to CISPR 32\u003cbr\u003eEmission tests conforming to IACS E10\u003cbr\u003eEMC immunity class 4 conforming to IEC 61000-4-2\u003cbr\u003eEMC immunity class 4 conforming to ANSI C37.90.3\u003cbr\u003eEMC immunity level 3 conforming to IEC 61000-4-3\u003cbr\u003eEMC immunity conforming to ANSI C37.90.2\u003cbr\u003eEMC immunity conforming to GOST 32137\u003cbr\u003eEMC immunity conforming to GOST 30804.4.3\u003cbr\u003eEMC immunity conforming to IACS E10\u003cbr\u003eEMC immunity level 5 conforming to IEC 61000-4-8\u003cbr\u003eEMC immunity level 5 conforming to IEC 61000-4-9\u003cbr\u003eEMC immunity level 5 conforming to IEC 61000-4-10\u003cbr\u003eEMC immunity level 3 conforming to IEC 61000-4-6\u003cbr\u003eEMC immunity level 3 conforming to IEC 61000-4-18\u003cbr\u003eEMC immunity conforming to ANSI C37.90.1\u003cbr\u003eEMC immunity conforming to IEC 61000-4-12\u003cbr\u003eEMC immunity conforming to GOST 30804.4.12\u003cbr\u003eEMC immunity level 4 conforming to IEC 61000-4-16\u003cbr\u003eEMC immunity level 4 conforming to IEC 61000-4-4\u003cbr\u003eEMC immunity level 4 conforming to IEC 61000-4-5\u003cbr\u003eAmbient air temperature for operation    -40…85 °C ( 16 h )\u003cbr\u003e-40…70 °C ( 96 h )\u003cbr\u003eAmbient air temperature for storage    -40…85 °C\u003cbr\u003eIP degree of protection    IP54 conforming to IEC 60529\u003cbr\u003emaximum operating altitude    2000 m\u003cbr\u003eProtective treatment    Conformal coating conforming to IEC 60068-2-52:Kb\/1\u003cbr\u003eConformal coating conforming to IEC 60068-2-60:Ke\u003cbr\u003eConformal coating conforming to IEC 60721-3-3:3C2\u003cbr\u003eRelative humidity    0…93 % at 40 °C, without condensation, 56 days\u003cbr\u003e93…95 % at 25…55 °C, 6 cycles, 12 + 12 hours\u003cbr\u003e\u003cstrong\u003ePacking Units\u003c\/strong\u003e\u003cbr\u003eUnit Type of Package 1    PCE\u003cbr\u003eNumber of Units in Package 1    1\u003cbr\u003ePackage 1 Height    30.0 cm\u003cbr\u003ePackage 1 Width    30.0 cm\u003cbr\u003ePackage 1 Length    35.0 cm\u003cbr\u003ePackage 1 Weight    4.5 kg\u003cbr\u003eContractual warranty\u003cbr\u003eWarranty (in months)    24\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":47675211153508,"sku":null,"price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/3791\/7796\/files\/files_2_af8e3733-bff9-488b-aa77-835aed557d21.png?v=1768016270"},{"product_id":"powerlogic™-p5m30-48-250v-3lpct-1csh-4lpvt-16di-12do","title":"PowerLogic™ P5M30 48-250V 3LPCT 1CSH 4LPVT 16DI-12DO","description":"\u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003cbr\u003eThe PowerLogic P5 is Schneider Electric's withdrawable protection and control relay for demanding medium voltage distribution applications. This motor relay offers withdrawable design with backup memory function enabling industry-leading 10 minute recovery time. It provides redundant Ethernet including IEC 61850 as well as plug and play communication modules that can evolve with your application. The product embeds latest cybersecurity functionality to help prevent intentional mis-use and cyber-threats. PowerLogic P5 offers safety, security, and connectivity built on more than 100 years of experience in protection relays. The PowerLogic P5 protection relay can be applied to all types of MV distribution networks. It can be supplied with 48 to 250 VDC and 100 to 230 VAC. It works with low power instrument transformers. 3 LPCT inputs, 1 Schneider Electric specific CSH neutral current input and 4 LPVT inputs. It offers 16 digital inputs and 12 digital outputs and no communications. Communication modules can be added any time. The product dimensions are 180 mm in height (7.09 in), 152,4 mm in width (6.00 in) and 224 mm in depth 8.82 in) for a net weight of 3.5 kg (7.7 lbs). PowerLogic P5 is compliant with EN 60255-26, EN 60255-27 standard and with UL Standard. It provides Marine certification. This product can be flush mounted on the panel or in the rack. Flush mounting frames to ensure IP54 are available. Fixing and wiring accessories are included. Plug and play communication modules: Ethernet RSTP RJ45 (REL51038), Ethernet RSTP FO (REL51039), Ethernet HSR\/PRP FO (REL51033). And also 2nd Ethernet RSTP RJ45 (REL51042), RS485 serial RJ45 (REL51036), RS485 serial FO (REL51040), Extension\/backup memory (REL51034). IP54 flush mounting frame (REL51052), CSH core-balance CTs (59635, 59636, 59637), 8 temperature sensor module (59641), IRIG-B module (REL51045). connection cords (59660, 59661, 59662), LPVT hub (EMS59573), VT adapter (EMS59572). eSetup Easergy Pro software with virtual injection testing and EcoStruxure Power Device app for simpler and safer operation and maintenance. Included with functions as per the datasheet below. For other configurations with additional functions and options, Please select via Product Selector.\u003cbr\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003cbr\u003eMain\u003cbr\u003eRange of product    PowerLogic P5\u003cbr\u003eProduct or component type    Protection and control relay\u003cbr\u003eRelay application    Motor\u003cbr\u003eproduct reference    P5M30-BACB-IAAAA-BAEA\u003cbr\u003eMounting case size    30TE\u003cbr\u003eDevice mounting    Flush\u003cbr\u003eMounting mode    Withdrawable\u003cbr\u003epower supply    48...250 V DC\u003cbr\u003e100...230 V AC\u003cbr\u003emeasuring inputs    : LPCT phase current 3\u003cbr\u003e: CSH residual current 1\u003cbr\u003e: LPVT voltage 4\u003cbr\u003eNumber of sensors    0 temperature sensor(s)\u003cbr\u003e0 arc sensor(s)\u003cbr\u003enumber of Digital Inputs (DI)    16\u003cbr\u003enumber of analogue inputs    0\u003cbr\u003enumber of Digital Outputs (DO)    11 DO\u003cbr\u003e1 watchdog\u003cbr\u003enumber of analogue outputs    0\u003cbr\u003ecommunication ports    USB port 2 front\u003cbr\u003ecommunication protocols    -\u003cbr\u003eCybersecurity    Port hardening\u003cbr\u003eFirmware signature\u003cbr\u003eClient IP address filter\u003cbr\u003eSecured communication with assciated tools\u003cbr\u003eSecurity policy management\u003cbr\u003eRole-based access control\u003cbr\u003eSecurity log\u003cbr\u003eLDAP\u003cbr\u003eRADIUS based user authentication\u003cbr\u003eIEC 62443-4-2 SL1\u003cbr\u003e\u003cstrong\u003eprotection functions\u003cbr\u003e\u003c\/strong\u003ePhase overcurrent 50\/51\u003cbr\u003eDirectional phase overcurrent 67\u003cbr\u003eEarth fault overcurrent 50N\/51N\u003cbr\u003eDirectional earth fault 67N\u003cbr\u003eTransient earth fault 67NI\u003cbr\u003eNeutral admittance 21YN\u003cbr\u003eEarth fault wattmetric 32N\u003cbr\u003eBroken conductor 46 I2\/I1\u003cbr\u003eCurrent unbalance 46 I2\/I1\u003cbr\u003eCold load pick-up\u003cbr\u003eSwitch ON to fault (SOTF)\u003cbr\u003eH2 detection\u003cbr\u003eH5 detection\u003cbr\u003eBreaker failure 50BF\u003cbr\u003eDirectional active underpower 37P\u003cbr\u003ePhase undercurrent 37\u003cbr\u003eExcessive starting time, locked rotor 48\/51LR\u003cbr\u003eMotor restart inhibition 66\u003cbr\u003eNegative sequence overcurrent 46\u003cbr\u003eOvervoltage 59\u003cbr\u003eUndervoltage 27\u003cbr\u003ePositive sequence undervoltage 27P\u003cbr\u003eEarth fault overvoltage 59N\u003cbr\u003eUnderfrequency 81\/81N\u003cbr\u003eLockout relay 86\u003cbr\u003eCT supervision 60\u003cbr\u003eVT supervision 60\u003cbr\u003eProgrammable stages 99\u003cbr\u003eProgrammable logic\u003cbr\u003eProgrammable curve\u003cbr\u003e\u003cstrong\u003emeasurement functions\u003cbr\u003e\u003c\/strong\u003eCurrent 3-phase\u003cbr\u003eCurrent zero sequence\u003cbr\u003eCurrent positive sequence\u003cbr\u003eCurrent negative sequence\u003cbr\u003eCurrent ratio of negative and positive\u003cbr\u003ePhasor diagram of currents or voltages\u003cbr\u003eCurrent 2nd, 15th harmonics with THD\u003cbr\u003eVoltage 3-phase\u003cbr\u003eVoltage residual\u003cbr\u003eVoltage zero sequence\u003cbr\u003eVoltage positive sequence\u003cbr\u003eVoltage negative sequence\u003cbr\u003eFrequency\u003cbr\u003e\u003cstrong\u003econtrol functions\u003cbr\u003e\u003c\/strong\u003eSwitchgear control and monitoring\u003cbr\u003eProgrammable switchgear interlocking\u003cbr\u003eLocal\/remote control\u003cbr\u003econtrollable switchgear devices    6 controlled + 2 monitored objects\u003cbr\u003enumber of setting groups    4\u003cbr\u003emonitoring functions    Trip circuit supervision 74\u003cbr\u003eCircuit breaker monitoring\u003cbr\u003eRelay self-monitoring\u003cbr\u003elogs and records    Event recording\u003cbr\u003eDisturbance recording\u003cbr\u003eTripping context\u003cbr\u003eRelay maintenance\u003cbr\u003eSwitchgear diagnosis type    CT\/VT supervision ANSI code: 60\u003cbr\u003eTrip circuit supervision ANSI code: 74\u003cbr\u003eConnections - terminals    Screw (digital input\/output)\u003cbr\u003eRing lugs (analog inputs and outputs)\u003cbr\u003eComplementary\u003cbr\u003eSoftware name    ESetup Easergy Pro: virtual simulation test\u003cbr\u003eDisplay type    Colour LCD 480 x 272 pixels\u003cbr\u003eNumber of key    7 customizable\u003cbr\u003eLocal signalling    4 x LED\u003cbr\u003e10 x LED tri-colour programmable\u003cbr\u003eHeight    176 mm\u003cbr\u003eWidth    152 mm\u003cbr\u003eDepth    219 mm\u003cbr\u003eNet weight    3.5 kg\u003cbr\u003eEnvironment\u003cbr\u003e\u003cstrong\u003eclimatic withstand\u003cbr\u003e\u003c\/strong\u003eExposure to cold conforming to IEC 60068-2-1\u003cbr\u003eExposure to dry heat conforming to IEC 60068-2-2\u003cbr\u003eExposure to damp heat in service conforming to IEC 60068-2-78\u003cbr\u003eExposure to damp heat in service conforming to IEC 60068-2-30\u003cbr\u003eTemperature variation conforming to IEC 60068-2-14\u003cbr\u003eSalt mist conforming to IEC 60068-2-52\u003cbr\u003eInfluence of corrosion\/gas test 2 conforming to IEC 60068-2-60\u003cbr\u003eInfluence of corrosion\/gas test 4 conforming to IEC 60068-2-60\u003cbr\u003eInfluence of corrosion\/gas test 2 conforming to IEC 60721-3-3\u003cbr\u003eInfluence of corrosion\/gas test 4 conforming to IEC 60721-3-3\u003cbr\u003eMechanical robustness    Vibrations (level: class 2) conforming to IEC 60255-21-1\u003cbr\u003eVibrations conforming to GOST 17516.1\u003cbr\u003eVibrations conforming to IACS E10\u003cbr\u003eShocks (level: class 2) conforming to IEC 60255-21-2\u003cbr\u003eEarthquakes (level: class 2) conforming to IEC 60255-21-3\u003cbr\u003e\u003cstrong\u003eElectromagnetic compatibility\u003cbr\u003e\u003c\/strong\u003eEmission tests class A conforming to CISPR 11\u003cbr\u003eEmission tests class A conforming to CISPR 32\u003cbr\u003eEmission tests conforming to IACS E10\u003cbr\u003eEMC immunity class 4 conforming to IEC 61000-4-2\u003cbr\u003eEMC immunity class 4 conforming to ANSI C37.90.3\u003cbr\u003eEMC immunity level 3 conforming to IEC 61000-4-3\u003cbr\u003eEMC immunity conforming to ANSI C37.90.2\u003cbr\u003eEMC immunity conforming to GOST 32137\u003cbr\u003eEMC immunity conforming to GOST 30804.4.3\u003cbr\u003eEMC immunity conforming to IACS E10\u003cbr\u003eEMC immunity level 5 conforming to IEC 61000-4-8\u003cbr\u003eEMC immunity level 5 conforming to IEC 61000-4-9\u003cbr\u003eEMC immunity level 5 conforming to IEC 61000-4-10\u003cbr\u003eEMC immunity level 3 conforming to IEC 61000-4-6\u003cbr\u003eEMC immunity level 3 conforming to IEC 61000-4-18\u003cbr\u003eEMC immunity conforming to ANSI C37.90.1\u003cbr\u003eEMC immunity conforming to IEC 61000-4-12\u003cbr\u003eEMC immunity conforming to GOST 30804.4.12\u003cbr\u003eEMC immunity level 4 conforming to IEC 61000-4-16\u003cbr\u003eEMC immunity level 4 conforming to IEC 61000-4-4\u003cbr\u003eEMC immunity level 4 conforming to IEC 61000-4-5\u003cbr\u003eAmbient air temperature for operation    -40…85 °C ( 16 h )\u003cbr\u003e-40…70 °C ( 96 h )\u003cbr\u003eAmbient air temperature for storage    -40…85 °C\u003cbr\u003eIP degree of protection    IP54 conforming to IEC 60529\u003cbr\u003emaximum operating altitude    2000 m\u003cbr\u003eProtective treatment    Conformal coating conforming to IEC 60068-2-52:Kb\/1\u003cbr\u003eConformal coating conforming to IEC 60068-2-60:Ke\u003cbr\u003eConformal coating conforming to IEC 60721-3-3:3C2\u003cbr\u003eRelative humidity    0…93 % at 40 °C, without condensation, 56 days\u003cbr\u003e93…95 % at 25…55 °C, 6 cycles, 12 + 12 hours\u003cbr\u003e\u003cstrong\u003ePacking Units\u003c\/strong\u003e\u003cbr\u003eUnit Type of Package 1    PCE\u003cbr\u003eNumber of Units in Package 1    1\u003cbr\u003ePackage 1 Height    30.0 cm\u003cbr\u003ePackage 1 Width    30.0 cm\u003cbr\u003ePackage 1 Length    35.0 cm\u003cbr\u003ePackage 1 Weight    4.5 kg\u003cbr\u003eContractual warranty\u003cbr\u003eWarranty (in months)    24\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":47675222425700,"sku":null,"price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/3791\/7796\/files\/files_3_b103d174-db86-4117-8cd6-13ef4883c536.png?v=1768016773"},{"product_id":"gha","title":"GHA","description":"\u003cp\u003e\u003cstrong\u003eGHA\u003c\/strong\u003e\u003cbr\u003eGas-Insulated (GIS) Primary Switchboard up to 40.5kV\u003cbr\u003e\u003cstrong\u003ePart of SeT\u003c\/strong\u003e Series\u003cbr\u003eGas Insulated Switchgear (GIS)\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":47675229372516,"sku":null,"price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/3791\/7796\/files\/files_4_23ff43b2-b7f1-432f-ae40-1f669ab80779.png?v=1768017233"},{"product_id":"primary-gas-insulated-switchgear-cbgs-0-bus-coupler-36kv-up-to-2000a-31-5ka","title":"Primary Gas Insulated Switchgear, CBGS-0, bus coupler, 36kV, up to 2000A, 31.5kA","description":"\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003cbr\u003eMain\u003cbr\u003eMaster range    SeT Series\u003cbr\u003eRange of product    CBGS-0\u003cbr\u003eProduct name    CBGS-0\u003cbr\u003eFunctional unit    Bus coupler\u003cbr\u003eInsulation technology    Gas insulated switchgear\u003cbr\u003eType of Insulating gas    SF6\u003cbr\u003eNumber of phases    3\u003cbr\u003eNetwork type    AC\u003cbr\u003eType of installation    Indoor installation\u003cbr\u003eBusbar system    Single busbar\u003cbr\u003eBusbar description    Sleeved busbar\u003cbr\u003eSwitching device    Disconnector\u003cbr\u003eStandards    IEC 62271-200\u003cbr\u003eRated voltage (Ur)    36 kV\u003cbr\u003eRated short-duration power frequency withstand voltage (Ud) \/ Common value    70 kV\u003cbr\u003eRated lightning impulse withstand voltage (Up) \/ Common value    170 kV\u003cbr\u003eRated frequency (fr)    50\/60 Hz\u003cbr\u003eRated continuous current of busbars (Ir)    2000 A\u003cbr\u003eRated continuous current (Ir)    630 A\u003cbr\u003e1250 A\u003cbr\u003e1600 A\u003cbr\u003e2000 A\u003cbr\u003eRated short-time withstand current (Ik)    25 kA\u003cbr\u003e31.5 kA\u003cbr\u003eRated duration of short-circuit (tk)    3 s\u003cbr\u003eRated peak withstand current (Ip)    65 kA 50 Hz\u003cbr\u003e82 kA 60 Hz\u003cbr\u003eFilling level for insulation and\/or switching (Pre rel.)    0.03 MPa\u003cbr\u003eLoss of service continuity category    LSC2\u003cbr\u003eInternal arc classification    AFL\u003cbr\u003eAFLR\u003cbr\u003eRated arc fault current (IA)    31.5 kA\u003cbr\u003eRated arc fault duration (tA)    1 s\u003cbr\u003eRated supply voltage of auxiliary and control circuits (Ua)    24\/48\/60\/110\/125\/220 V DC\u003cbr\u003e48 V AC 50 Hz\u003cbr\u003e110 V AC 50 Hz\u003cbr\u003e125 V AC 50 Hz\u003cbr\u003e220 V AC 50 Hz\u003cbr\u003e120 V AC 60 Hz\u003cbr\u003eComplementary\u003cbr\u003eDegrees of protection provided by enclosures (IP code)    IP65 (functional unit)\u003cbr\u003eIP3X (LV control compartment)\u003cbr\u003eIP41 (LV control compartment)\u003cbr\u003eInstrument transformer    Current transformer\u003cbr\u003eVoltage presence type    VPIS voltage presence indicating system\u003cbr\u003eVDS voltage detecting system\u003cbr\u003eSensor type    CL110 environmental sensor\u003cbr\u003eTH110 thermal sensor\u003cbr\u003e\u003cstrong\u003eProtection relay\u003cbr\u003e\u003c\/strong\u003eEasergy P3\u003cbr\u003eEasergy P5\u003cbr\u003eEasergy Sepam series 60\u003cbr\u003eEasergy Sepam series 80\u003cbr\u003eEasergy MiCOM P30 series\u003cbr\u003eEasergy MiCOM P40 series\u003cbr\u003eArc fault detector    Easergy Vamp 121\u003cbr\u003eEasergy Vamp 125\u003cbr\u003eEasergy Vamp 321\u003cbr\u003eCable type    Single core\u003cbr\u003eCable cross-section    0 to 1200 mm²\u003cbr\u003eNumber of cables per phase    Up to 3\u003cbr\u003eMass    930 kg\u003cbr\u003eHeight    2350 mm\u003cbr\u003eWidth    600 mm\u003cbr\u003eDepth    1400 mm\u003cbr\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003cbr\u003eAmbient air temperature for operation    -5…40 °C\u003cbr\u003eAmbient air temperature for storage    -25…55 °C\u003cbr\u003eHumidity conditions    Average relative humidity over 24 h \u0026lt;= 95 %\u003cbr\u003eAverage relative humidity over 1 month \u0026lt;= 90 %\u003cbr\u003eOperating altitude    \u0026lt;= 2000 m\u003cbr\u003eContractual warranty\u003cbr\u003eWarranty (in months)    18\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":47675233861732,"sku":null,"price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/3791\/7796\/files\/files_5_5c1de87d-ef04-4f84-8c2e-9482112582af.png?v=1768017475"},{"product_id":"primary-gas-insulated-switchgear-cbgs-0-cable-riser-36kv-up-to-2000a-31-5ka","title":"Primary Gas Insulated Switchgear, CBGS-0, cable riser, 36kV, up to 2000A, 31.5kA","description":"\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003cbr\u003eMain\u003cbr\u003eMaster range    SeT Series\u003cbr\u003eRange of product    CBGS-0\u003cbr\u003eProduct name    CBGS-0\u003cbr\u003eFunctional unit    CR coupler riser\u003cbr\u003eInsulation technology    Gas insulated switchgear\u003cbr\u003eType of Insulating gas    SF6\u003cbr\u003eNumber of phases    3\u003cbr\u003eNetwork type    AC\u003cbr\u003e\u003cstrong\u003eType of installation\u003cbr\u003e\u003c\/strong\u003eIndoor installation\u003cbr\u003eBusbar system    Single busbar\u003cbr\u003eBusbar description    Sleeved busbar\u003cbr\u003eSwitching device    SF6 circuit breaker\u003cbr\u003eVacuum circuit breaker\u003cbr\u003eStandards    IEC 62271-200\u003cbr\u003eRated voltage (Ur)    36 kV\u003cbr\u003eRated short-duration power frequency withstand voltage (Ud) \/ Common value    70 kV\u003cbr\u003eRated lightning impulse withstand voltage (Up) \/ Common value    170 kV\u003cbr\u003eRated frequency (fr)    50\/60 Hz\u003cbr\u003eRated continuous current of busbars (Ir)    2000 A\u003cbr\u003eRated continuous current (Ir)    1250 A\u003cbr\u003e1600 A\u003cbr\u003e2000 A\u003cbr\u003eRated short-circuit breaking current (Isc)    25 kA\u003cbr\u003e31.5 kA\u003cbr\u003eRated short-circuit making current    65 kA 50 Hz\u003cbr\u003e82 kA 60 Hz\u003cbr\u003eRated short-time withstand current (Ik)    25 kA\u003cbr\u003e31.5 kA\u003cbr\u003eRated duration of short-circuit (tk)    3 s\u003cbr\u003eRated peak withstand current (Ip)    65 kA 50 Hz\u003cbr\u003e82 kA 60 Hz\u003cbr\u003eFilling level for insulation and\/or switching (Pre rel.)    0.03 MPa\u003cbr\u003eLoss of service continuity category    LSC2\u003cbr\u003eInternal arc classification    AFL\u003cbr\u003eAFLR\u003cbr\u003eRated arc fault current (IA)    31.5 kA\u003cbr\u003eRated arc fault duration (tA)    1 s\u003cbr\u003eRated supply voltage of auxiliary and control circuits (Ua)    24\/48\/60\/110\/125\/220 V DC\u003cbr\u003e48 V AC 50 Hz\u003cbr\u003e110 V AC 50 Hz\u003cbr\u003e125 V AC 50 Hz\u003cbr\u003e220 V AC 50 Hz\u003cbr\u003e120 V AC 60 Hz\u003cbr\u003eComplementary\u003cbr\u003eDegrees of protection provided by enclosures (IP code)    IP65 (functional unit)\u003cbr\u003eIP3X (LV control compartment)\u003cbr\u003eIP41 (LV control compartment)\u003cbr\u003eInstrument transformer    Current transformer\u003cbr\u003eVoltage transformer\u003cbr\u003eVoltage presence type    VPIS voltage presence indicating system\u003cbr\u003eVDS voltage detecting system\u003cbr\u003eSensor type    CL110 environmental sensor\u003cbr\u003eTH110 thermal sensor\u003cbr\u003e\u003cstrong\u003eProtection relay\u003c\/strong\u003e\u003cbr\u003eEasergy P3\u003cbr\u003eEasergy P5\u003cbr\u003eEasergy Sepam series 60\u003cbr\u003eEasergy Sepam series 80\u003cbr\u003eEasergy MiCOM P30 series\u003cbr\u003eEasergy MiCOM P40 series\u003cbr\u003eArc fault detector    Easergy Vamp 121\u003cbr\u003eEasergy Vamp 125\u003cbr\u003eEasergy Vamp 321\u003cbr\u003eCable type    Single core\u003cbr\u003eCable cross-section    0 to 1200 mm²\u003cbr\u003eNumber of cables per phase    Up to 3\u003cbr\u003eMass    930 kg\u003cbr\u003eHeight    2350 mm\u003cbr\u003eWidth    600 mm\u003cbr\u003eDepth    1400 mm\u003cbr\u003eEnvironment\u003cbr\u003eAmbient air temperature for operation    -5…40 °C\u003cbr\u003eAmbient air temperature for storage    -25…55 °C\u003cbr\u003eHumidity conditions    Average relative humidity over 24 h \u0026lt;= 95 %\u003cbr\u003eAverage relative humidity over 1 month \u0026lt;= 90 %\u003cbr\u003eOperating altitude    \u0026lt;= 2000 m\u003cbr\u003eContractual warranty\u003cbr\u003eWarranty (in months)    18\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":47675238121572,"sku":null,"price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/3791\/7796\/files\/files_6_b535344d-610e-400b-926a-387351814fa0.png?v=1768017694"}],"url":"https:\/\/www.jublipower.com\/collections\/primary-gas-insulated-switchgear.oembed?page=2","provider":"Jublipower","version":"1.0","type":"link"}