{"title":"Primary Air Insulated Switchgear","description":"","products":[{"product_id":"mcset-17-5-kv","title":"MCSet 17.5 kV","description":"\u003cp\u003e\u003cstrong\u003eMCSet 17.5 kV\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePrimary AIS MV Switchgear withdrawable CB up to 17.5 kV 4000A\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePart of SeT Series\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMCSet 17.5 kV is an indoor switchgear assembly that provides maximum user safety.It is intended to meet all electrical distribution needs up to 17.5kV and incorporates a set of innovative solutions\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":47647813959780,"sku":null,"price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/3791\/7796\/files\/files_22.png?v=1767780373"},{"product_id":"pix-50-ka","title":"PIX 50 kA","description":"\u003cp\u003e\u003cstrong\u003ePIX 50 kA\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePrimary AIS MV Switchgear with vacuum CB High Ratings up to 17.5 kV 50 kA\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePart of SeT Series\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eHigh rated vacuum circuit breaker for heavy industry, power stations and oil and gas processes\u003cbr\u003eDiscover PIX 50 kA\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEnhanced performance\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003ePIX High incorporates the latest design features including operational safety, technical performance, and optimized internal arc capabilities.\u003cbr\u003ePIX High cubicle structure offers an especially rugged construction, suitable for the harshest of environments.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":47647837651044,"sku":null,"price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/3791\/7796\/files\/files_23.png?v=1767780737"},{"product_id":"pix-mcc","title":"PIX MCC","description":"\u003cp\u003e\u003cstrong\u003ePIX MCC\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePIX MCC is a “Slimline” single tier Fused Vacuum contactor up to 7.2 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePart of SeT\u003c\/strong\u003e Series\u003c\/p\u003e\n\u003cp\u003eAir Insulated Switchgear (AIS)\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":47647856263268,"sku":null,"price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/3791\/7796\/files\/files_24.png?v=1767780976"},{"product_id":"mcset-24-kv","title":"MCSet 24 kV","description":"\u003cp\u003e\u003cstrong\u003eMCSet 24 kV\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePrimary AIS MV Switchgear up to 24 kV 2500 A\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePart of SeT\u003c\/strong\u003e Series\u003c\/p\u003e\n\u003cp\u003eMCSet 24 kV is an indoor switchgear assembly that provides maximum user safety. It is intended to meet all electrical distribution needs from 24kV and incorporates a set of innovative solutions designed using proven techniques\u003cbr\u003eDiscover MCSet 24 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA set of innovative solutions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMCSet 24 kV is an indoor switchgear assembly that provides maximum user safety. It is present in all electrical distribution markets intended to meet all electrical distribution needs from 24kV.\u003cbr\u003eMCset is designed for the MV section of HV \/ MV substations and high-power MV \/ MV substations.\u003cbr\u003e\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":47647930155108,"sku":null,"price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/3791\/7796\/files\/files_25.png?v=1767781212"},{"product_id":"mcset-with-evopact","title":"MCSeT with EvoPacT","description":"\u003cp\u003e\u003cstrong\u003eMCSeT with EvoPacT\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePrimary AIS MV Switchgear up to 24 kV – IoT-Connected Solution with EvoPacT HVX Circuit Breaker\u003cbr\u003e\u003cstrong\u003ePart of SeT\u003c\/strong\u003e Series\u003c\/p\u003e\n\u003cp\u003ePrimary air-insulated (AIS) MV switchgear designed for medium voltage indoor installations. IoT connected, it features the EvoPacT HVX withdrawable circuit breaker (CB), and delivers comprehensive health monitoring. Built for 12 kV, 17.5 kV, and 24 kV electrical distribution, MCSeT ensures enhanced safety, long-lasting performance, and smart monitoring for modern electric distribution.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMCSeT is a smart modular indoor medium voltage switchgear, that incorporates a range of innovative solutions designed using proven techniques. It helps users manage safe and reliable access to primary distribution electrical networks in HV\/MV or MV\/MV substations.\u003cbr\u003eNew Active variants include scalable and embedded condition monitoring sensors and anywhere operation. Enabled by 24\/7 connectivity and condition monitoring, MCSeT helps simplify everyday operations and maintenance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBenefits\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSafety and reliability\u003cbr\u003e•    Remote switchgear operations provide enhanced operator safety\u003cbr\u003e•    High-quality design, using an inner cradle for breaker operations\u003cbr\u003e•    Independent type tests and systematic checks\u003cbr\u003e•    Operate live equipment from outside of the arc flash zone\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSimplicity\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e•    Easy to install and maintain\u003cbr\u003e•    Smart and compact, with high performance\u003cbr\u003e•    Simple operations, with front-door-mounted direct mechanical push buttons\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEfficiency\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e•    Save time with less manual interventions\u003cbr\u003e•    Remote operation of the circuit breaker and the earthing switch\u003cbr\u003e•    More sustainable, longer life with less total maintenance expenses\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe perfect partner with EcoCare membership\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIoT connectivity and health sensors are the perfect partner for our new EcoCare membership, for comprehensive and seamless condition-based maintenance packages, monitoring, alerts, warranty extension, technical support and more. Ask your local Schneider representative for more information on how EcoCare membership allows you to take your switchgear to the next level.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e•    Healthcare\u003cbr\u003e•    Mining, Minerals and Metals\u003cbr\u003e•    Power, Grid \u0026amp; Utilities\u003cbr\u003e•    Commercial \u0026amp; Industrial buildings\u003cbr\u003e•    Food and beverages\u003cbr\u003e•    Water \u0026amp; Wastewater treatment\u003cbr\u003e•    Automotive\u003cbr\u003e•    Hotels\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":47648100745316,"sku":null,"price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/3791\/7796\/files\/files_26.png?v=1767781458"},{"product_id":"genieevo","title":"GenieEvo","description":"\u003cp\u003e\u003cstrong\u003eGenieEvo\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMV fixed pattern modular switchboard up to 13.8 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePart of SeT\u003c\/strong\u003e Series\u003c\/p\u003e\n\u003cp\u003eGenieEvo is a comprehensive, environmentally insensitive medium voltage switchgear range for utilities, MV consumer and industrial substations, data centers, large commercial centers, hospitals applications\u003cbr\u003eDiscover GenieEvo\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA simple and flexible approach to switchgear\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eGenieEvo is a comprehensive, environmentally insensitive medium voltage switchgear range. With quick delivery, advanced safety features and compliance with the most stringent standards, it offers you an innovative, simple and highly reliable solution to your primary or secondary distribution needs.\u003cbr\u003eIt offers 6 switchgear options and 18 protection and control module options, providing a total of 69 standard panel combinations. Customised solutions are also available on request.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePre-engineered metalclad switchgear including\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e•    Cast resin encapsulated MV system\u003cbr\u003e•    Demountable Evolis EXE vacuum circuit breaker\u003cbr\u003e•    Controlled air, resin encapsulated series disconnector\u003cbr\u003e•    Rated voltage: 13.8 kV\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e25 kA version:\u003c\/p\u003e\n\u003cp\u003e•    Rated current: 200, 630, 1250, 2000, 2500 A\u003cbr\u003e•    Rated short time withstand current: up to 25 kA \/ 3 s\u003cbr\u003e•    Internal Arc AF, AFLR 25 kA \/ 1 s\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e31.5 kA version:\u003c\/p\u003e\n\u003cp\u003e•    Rated current: 200, 630, 1250, 2000 A\u003cbr\u003e•    Rated short time withstand current: up to 31.5 kA \/ 3 s\u003cbr\u003e•    Internal Arc – AFLR 31.5 kA \/ 1 s\u003cbr\u003e•    Flexible pre-engineered protection and control modules (PowerLogic P3, PowerLogic P5, Micom)\u003cbr\u003e•    Power Logic advanced Electrical Network Management System\u003cbr\u003e•    Smart grid and asset management ready\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProtect your GenieEvo with EcoCare\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWith EcoCare membership*, a next-generation service plan, you gain exclusive support for your equipment from day 1 and throughout its entire lifecycle. For minimal investment compared with your overall CapEx. you'll enjoy 24\/7 remote monitoring and alarm management, and access to technical expertise, on-site and remotely, as defined by the service level agreement (SLA). This proactive approach helps reduce the risk of unexpected downtime and related costs while enhancing your operations' uptime, safety, and efficiency.\u003cbr\u003e\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":47648172736612,"sku":null,"price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/3791\/7796\/files\/files_27.png?v=1767781780"},{"product_id":"primary-air-insulated-switchgear-pix-incomer-feeder-functional-unit-12kv-upto-1250a-upto-40ka-3s-width-650mm","title":"Primary Air Insulated Switchgear, PIX, incomer \u0026 feeder functional unit, 12kV, upto 1250A, upto 40kA 3s, width 650mm","description":"\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003cbr\u003eMain\u003cbr\u003eMaster range    SeT Series\u003cbr\u003eRange of product    PIX\u003cbr\u003eProduct name    PIX 12\u003cbr\u003eFunctional unit    Incomer\u003cbr\u003eFeeder\u003cbr\u003eInsulation technology    Air insulated switchgear\u003cbr\u003eNumber of phases    3\u003cbr\u003eNetwork type    AC\u003cbr\u003eType of installation    Indoor\u003cbr\u003eBusbar system    Single busbar\u003cbr\u003eSwitching device    Vacuum circuit breaker\u003cbr\u003eProduct compatibility    EvoPact HVX\u003cbr\u003eStandards    IEC 62271-200\u003cbr\u003eRated voltage (Ur)    12 kV\u003cbr\u003eRated short-duration power frequency withstand voltage (Ud) \/ Common value    28 kV\u003cbr\u003eRated lightning impulse withstand voltage (Up) \/ Common value    75 kV\u003cbr\u003eRated frequency (fr)    50\/60 Hz\u003cbr\u003eRated continuous current of busbars (Ir)    4000 A\u003cbr\u003eRated continuous current (Ir)    800 A\u003cbr\u003e1250 A\u003cbr\u003e\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":47677192208484,"sku":null,"price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/3791\/7796\/files\/RNG_60678_main_image_369.jpg?v=1768030333"},{"product_id":"primary-air-insulated-switchgear-pix-incomer-feeder-functional-unit-12kv-upto-2000a-upto-40ka-3s-width-800mm","title":"Primary Air Insulated Switchgear, PIX, incomer \u0026 feeder functional unit, 12kV, upto 2000A, upto 40kA 3s, width 800mm","description":"\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003cbr\u003eMain\u003cbr\u003eMaster range    SeT Series\u003cbr\u003eRange of product    PIX\u003cbr\u003eProduct name    PIX 12\u003cbr\u003eFunctional unit    Incomer\u003cbr\u003eFeeder\u003cbr\u003eInsulation technology    Air insulated switchgear\u003cbr\u003eNumber of phases    3\u003cbr\u003eNetwork type    AC\u003cbr\u003eType of installation    Indoor\u003cbr\u003eBusbar system    Single busbar\u003cbr\u003eSwitching device    Vacuum circuit breaker\u003cbr\u003eProduct compatibility    EvoPact HVX\u003cbr\u003eStandards    IEC 62271-200\u003cbr\u003eRated voltage (Ur)    12 kV\u003cbr\u003eRated short-duration power frequency withstand voltage (Ud) \/ Common value    28 kV\u003cbr\u003eRated lightning impulse withstand voltage (Up) \/ Common value    75 kV\u003cbr\u003eRated frequency (fr)    50\/60 Hz\u003cbr\u003eRated continuous current of busbars (Ir)    4000 A\u003cbr\u003eRated continuous current (Ir)    1600 A\u003cbr\u003e2000 A\u003cbr\u003eRated short-circuit breaking current (Isc)    40 kA\u003cbr\u003eRated short-circuit making current    100 kA 50 Hz\u003cbr\u003e104 kA 60 Hz\u003cbr\u003eRated short-time withstand current (Ik)    25 kA\u003cbr\u003e31.5 kA\u003cbr\u003e40 kA\u003cbr\u003eRated duration of short-circuit (tk)    3 s\u003cbr\u003eRated peak withstand current (Ip)    100 kA 50 Hz\u003cbr\u003e104 kA 60 Hz\u003cbr\u003eLoss of service continuity category    LSC2B\u003cbr\u003eInternal arc classification    AFLR\u003cbr\u003eRated arc fault current (IA)    40 kA\u003cbr\u003eRated arc fault duration (tA)    1 s\u003cbr\u003eInternal arc gas evacuation    Upwards inside the room\u003cbr\u003eUpwards outside the room\u003cbr\u003ePartition class    PM\u003c\/p\u003e\n\u003cp\u003eComplementary\u003cbr\u003eDegrees of protection provided by enclosures (IP code)    IP3X\u003cbr\u003eIP4X\u003cbr\u003eIPX2\u003cbr\u003eIP2X (between compartments)\u003cbr\u003eDegree of protection of enclosure against external mechanical impacts (IK code)    IK07\u003cbr\u003eInstrument transformer    Current transformer\u003cbr\u003eVoltage transformer\u003cbr\u003eSurge arrester\u003cbr\u003eSensor type    TH110 thermal sensor\u003cbr\u003eCL110 environmental sensor\u003cbr\u003ePD100 partial discharges monitoring solution\u003cbr\u003eVoltage presence type    VPIS voltage presence indicating system\u003cbr\u003eVDIS voltage detecting and indicating system\u003cbr\u003eProtection relay    Easergy P3\u003cbr\u003eEasergy P5\u003cbr\u003eEasergy Sepam series 60\u003cbr\u003eEasergy Sepam series 80\u003cbr\u003eArc fault detector    Easergy Vamp 125\u003cbr\u003eCable type    Single core\u003cbr\u003eThree core\u003cbr\u003eCable cross-section    630 mm²\u003cbr\u003eNumber of cables per phase    Up to 4\u003cbr\u003eMass    850 kg\u003cbr\u003eHeight    2130 mm (standard)\u003cbr\u003e2690 mm (with deflector)\u003cbr\u003e2730 mm (tunnel with external exhaust)\u003cbr\u003e3180 mm (tunnel with absorber)\u003cbr\u003eWidth    800 mm\u003cbr\u003eDepth    1405 mm\u003cbr\u003e1605 mm\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003cbr\u003eProduct certifications    BV Marine\u003cbr\u003eDNV-GL Marine\u003cbr\u003eAmbient air temperature for operation    -5…40 °C\u003cbr\u003eAmbient air temperature for storage    -25…55 °C\u003cbr\u003eHumidity conditions    Average relative humidity over 24 h \u0026lt;= 95 %\u003cbr\u003eAverage relative humidity over 1 month \u0026lt;= 90 %\u003cbr\u003eOperating altitude    \u0026lt;= 1000 m\u003c\/p\u003e\n\u003cp\u003eContractual warranty\u003cbr\u003eWarranty (in months)    18\u003cbr\u003e\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":47677767123044,"sku":null,"price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/3791\/7796\/files\/RNG_60678_main_image_369_1.jpg?v=1768039710"},{"product_id":"primary-air-insulated-switchgear-pix-incomer-feeder-functional-unit-12kv-upto-4000a-upto-40ka-3s-width-1000mm","title":"Primary Air Insulated Switchgear, PIX, incomer \u0026 feeder functional unit, 12kV, upto 4000A, upto 40kA 3s, width 1000mm","description":"\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003cbr\u003eMain\u003cbr\u003eMaster range    SeT Series\u003cbr\u003eRange of product    PIX\u003cbr\u003eProduct name    PIX 12\u003cbr\u003eFunctional unit    Incomer\u003cbr\u003eFeeder\u003cbr\u003eInsulation technology    Air insulated switchgear\u003cbr\u003eNumber of phases    3\u003cbr\u003eNetwork type    AC\u003cbr\u003eType of installation    Indoor\u003cbr\u003eBusbar system    Single busbar\u003cbr\u003eSwitching device    Vacuum circuit breaker\u003cbr\u003eProduct compatibility    EvoPact HVX\u003cbr\u003eStandards    IEC 62271-200\u003cbr\u003eRated voltage (Ur)    12 kV\u003cbr\u003eRated short-duration power frequency withstand voltage (Ud) \/ Common value    28 kV\u003cbr\u003eRated lightning impulse withstand voltage (Up) \/ Common value    75 kV\u003cbr\u003eRated frequency (fr)    50\/60 Hz\u003cbr\u003eRated continuous current of busbars (Ir)    4000 A\u003cbr\u003eRated continuous current (Ir)    2500 A\u003cbr\u003e3150 A\u003cbr\u003e4000 A\u003cbr\u003eRated short-circuit breaking current (Isc)    40 kA\u003cbr\u003eRated short-circuit making current    100 kA 50 Hz\u003cbr\u003e104 kA 60 Hz\u003cbr\u003eRated short-time withstand current (Ik)    25 kA\u003cbr\u003e31.5 kA\u003cbr\u003e40 kA\u003cbr\u003eRated duration of short-circuit (tk)    3 s\u003cbr\u003eRated peak withstand current (Ip)    100 kA 50 Hz\u003cbr\u003e104 kA 60 Hz\u003cbr\u003eLoss of service continuity category    LSC2B\u003cbr\u003eInternal arc classification    AFLR\u003cbr\u003eRated arc fault current (IA)    40 kA\u003cbr\u003eRated arc fault duration (tA)    1 s\u003cbr\u003eInternal arc gas evacuation    Upwards inside the room\u003cbr\u003eUpwards outside the room\u003cbr\u003ePartition class    PM\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eComplementary\u003c\/strong\u003e\u003cbr\u003eDegrees of protection provided by enclosures (IP code)    IP3X\u003cbr\u003eIP4X\u003cbr\u003eIPX2\u003cbr\u003eIP2X (between compartments)\u003cbr\u003eDegree of protection of enclosure against external mechanical impacts (IK code)    IK07\u003cbr\u003eInstrument transformer    Current transformer\u003cbr\u003eVoltage transformer\u003cbr\u003eSurge arrester\u003cbr\u003eSensor type    TH110 thermal sensor\u003cbr\u003eCL110 environmental sensor\u003cbr\u003ePD100 partial discharges monitoring solution\u003cbr\u003eVoltage presence type    VPIS voltage presence indicating system\u003cbr\u003eVDIS voltage detecting and indicating system\u003cbr\u003eProtection relay    Easergy P3\u003cbr\u003eEasergy P5\u003cbr\u003eEasergy Sepam series 60\u003cbr\u003eEasergy Sepam series 80\u003cbr\u003eArc fault detector    Easergy Vamp 125\u003cbr\u003eCable type    Single core\u003cbr\u003eThree core\u003cbr\u003eCable cross-section    630 mm²\u003cbr\u003eNumber of cables per phase    4 to 8\u003cbr\u003eMass    1100 kg\u003cbr\u003eHeight    2130 mm (standard)\u003cbr\u003e2690 mm (with deflector)\u003cbr\u003e2730 mm (tunnel with external exhaust)\u003cbr\u003e3180 mm (tunnel with absorber)\u003cbr\u003eWidth    1000 mm\u003cbr\u003eDepth    1405 mm\u003cbr\u003e1605 mm\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003cbr\u003eProduct certifications    BV Marine\u003cbr\u003eDNV-GL Marine\u003cbr\u003eAmbient air temperature for operation    -5…40 °C\u003cbr\u003eAmbient air temperature for storage    -25…55 °C\u003cbr\u003eHumidity conditions    Average relative humidity over 24 h \u0026lt;= 95 %\u003cbr\u003eAverage relative humidity over 1 month \u0026lt;= 90 %\u003cbr\u003eOperating altitude    \u0026lt;= 1000 m\u003c\/p\u003e\n\u003cp\u003eContractual warranty\u003cbr\u003eWarranty (in months)    18\u003cbr\u003e\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":47677790158948,"sku":null,"price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/3791\/7796\/files\/RNG_60678_main_image_369_2.jpg?v=1768039963"},{"product_id":"primary-air-insulated-switchgear-pix-bus-riser-functional-unit-12kv-1250a-upto-40ka-3s-width-650mm","title":"Primary Air Insulated Switchgear, PIX, bus riser functional unit, 12kV, 1250A, upto 40kA 3s, width 650mm","description":"\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003cbr\u003eMain\u003cbr\u003eMaster range    SeT Series\u003cbr\u003eRange of product    PIX\u003cbr\u003eProduct name    PIX 12\u003cbr\u003eFunctional unit    BC bus coupler cubicle\u003cbr\u003eInsulation technology    Air insulated switchgear\u003cbr\u003eNumber of phases    3\u003cbr\u003eNetwork type    AC\u003cbr\u003eType of installation    Indoor\u003cbr\u003eBusbar system    Single busbar\u003cbr\u003eSwitching device    Vacuum circuit breaker\u003cbr\u003eProduct compatibility    EvoPact HVX\u003cbr\u003eStandards    IEC 62271-200\u003cbr\u003eRated voltage (Ur)    12 kV\u003cbr\u003eRated short-duration power frequency withstand voltage (Ud) \/ Common value    28 kV\u003cbr\u003eRated lightning impulse withstand voltage (Up) \/ Common value    75 kV\u003cbr\u003eRated frequency (fr)    50\/60 Hz\u003cbr\u003eRated continuous current of busbars (Ir)    4000 A\u003cbr\u003eRated continuous current (Ir)    800 A\u003cbr\u003e1250 A\u003cbr\u003eRated short-circuit breaking current (Isc)    40 kA\u003cbr\u003eRated short-circuit making current    100 kA 50 Hz\u003cbr\u003e104 kA 60 Hz\u003cbr\u003eRated short-time withstand current (Ik)    25 kA\u003cbr\u003e31.5 kA\u003cbr\u003e40 kA\u003cbr\u003eRated duration of short-circuit (tk)    3 s\u003cbr\u003eRated peak withstand current (Ip)    100 kA 50 Hz\u003cbr\u003e104 kA 60 Hz\u003cbr\u003eLoss of service continuity category    LSC2B\u003cbr\u003eInternal arc classification    AFLR\u003cbr\u003eRated arc fault current (IA)    40 kA\u003cbr\u003eRated arc fault duration (tA)    1 s\u003cbr\u003eInternal arc gas evacuation    Upwards inside the room\u003cbr\u003eUpwards outside the room\u003cbr\u003ePartition class    PM\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eComplementary\u003c\/strong\u003e\u003cbr\u003eDegrees of protection provided by enclosures (IP code)    IP3X\u003cbr\u003eIP4X\u003cbr\u003eIPX2\u003cbr\u003eIP2X (between compartments)\u003cbr\u003eDegree of protection of enclosure against external mechanical impacts (IK code)    IK07\u003cbr\u003eInstrument transformer    Current transformer\u003cbr\u003eSensor type    TH110 thermal sensor\u003cbr\u003eCL110 environmental sensor\u003cbr\u003ePD100 partial discharges monitoring solution\u003cbr\u003eVoltage presence type    VPIS voltage presence indicating system\u003cbr\u003eVDIS voltage detecting and indicating system\u003cbr\u003eProtection relay    Easergy P3\u003cbr\u003eEasergy P5\u003cbr\u003eEasergy Sepam series 60\u003cbr\u003eEasergy Sepam series 80\u003cbr\u003eArc fault detector    Easergy Vamp 125\u003cbr\u003eMass    750 kg\u003cbr\u003eHeight    2130 mm (standard)\u003cbr\u003e2690 mm (with deflector)\u003cbr\u003e2730 mm (tunnel with external exhaust)\u003cbr\u003e3180 mm (tunnel with absorber)\u003cbr\u003eWidth    650 mm\u003cbr\u003eDepth    1405 mm\u003cbr\u003e1605 mm\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003cbr\u003eProduct certifications    BV Marine\u003cbr\u003eDNV-GL Marine\u003cbr\u003eAmbient air temperature for operation    -5…40 °C\u003cbr\u003eAmbient air temperature for storage    -25…55 °C\u003cbr\u003eHumidity conditions    Average relative humidity over 24 h \u0026lt;= 95 %\u003cbr\u003eAverage relative humidity over 1 month \u0026lt;= 90 %\u003cbr\u003eOperating altitude    \u0026lt;= 1000 m\u003c\/p\u003e\n\u003cp\u003eContractual warranty\u003cbr\u003eWarranty (in months)    18\u003cbr\u003e\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":47677827874916,"sku":null,"price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/3791\/7796\/files\/RNG_60678_main_image_369_3.jpg?v=1768040914"},{"product_id":"primary-air-insulated-switchgear-pix-bus-coupler-functional-unit-12kv-2000a-upto-40ka-3s-width-800mm","title":"Primary Air Insulated Switchgear, PIX, bus coupler functional unit, 12kV, 2000A, upto 40kA 3s, width 800mm","description":"\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003cbr\u003eMain\u003cbr\u003eMaster range    SeT Series\u003cbr\u003eRange of product    PIX\u003cbr\u003eProduct name    PIX 12\u003cbr\u003eFunctional unit    BC bus coupler cubicle\u003cbr\u003eInsulation technology    Air insulated switchgear\u003cbr\u003eNumber of phases    3\u003cbr\u003eNetwork type    AC\u003cbr\u003eType of installation    Indoor\u003cbr\u003eBusbar system    Single busbar\u003cbr\u003eSwitching device    Vacuum circuit breaker\u003cbr\u003eProduct compatibility    EvoPact HVX\u003cbr\u003eStandards    IEC 62271-200\u003cbr\u003eRated voltage (Ur)    12 kV\u003cbr\u003eRated short-duration power frequency withstand voltage (Ud) \/ Common value    28 kV\u003cbr\u003eRated lightning impulse withstand voltage (Up) \/ Common value    75 kV\u003cbr\u003eRated frequency (fr)    50\/60 Hz\u003cbr\u003eRated continuous current of busbars (Ir)    4000 A\u003cbr\u003eRated continuous current (Ir)    1600 A\u003cbr\u003e2000 A\u003cbr\u003eRated short-circuit breaking current (Isc)    40 kA\u003cbr\u003eRated short-circuit making current    100 kA 50 Hz\u003cbr\u003e104 kA 60 Hz\u003cbr\u003eRated short-time withstand current (Ik)    25 kA\u003cbr\u003e31.5 kA\u003cbr\u003e40 kA\u003cbr\u003eRated duration of short-circuit (tk)    3 s\u003cbr\u003eRated peak withstand current (Ip)    100 kA 50 Hz\u003cbr\u003e104 kA 60 Hz\u003cbr\u003eLoss of service continuity category    LSC2B\u003cbr\u003eInternal arc classification    AFLR\u003cbr\u003eRated arc fault current (IA)    40 kA\u003cbr\u003eRated arc fault duration (tA)    1 s\u003cbr\u003eInternal arc gas evacuation    Upwards inside the room\u003cbr\u003eUpwards outside the room\u003cbr\u003ePartition class    PM\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eComplementary\u003c\/strong\u003e\u003cbr\u003eDegrees of protection provided by enclosures (IP code)    IP3X\u003cbr\u003eIP4X\u003cbr\u003eIPX2\u003cbr\u003eIP2X (between compartments)\u003cbr\u003eDegree of protection of enclosure against external mechanical impacts (IK code)    IK07\u003cbr\u003eInstrument transformer    Current transformer\u003cbr\u003eSensor type    TH110 thermal sensor\u003cbr\u003eCL110 environmental sensor\u003cbr\u003ePD100 partial discharges monitoring solution\u003cbr\u003eVoltage presence type    VPIS voltage presence indicating system\u003cbr\u003eVDIS voltage detecting and indicating system\u003cbr\u003eProtection relay    Easergy P3\u003cbr\u003eEasergy P5\u003cbr\u003eEasergy Sepam series 60\u003cbr\u003eEasergy Sepam series 80\u003cbr\u003eArc fault detector    Easergy Vamp 125\u003cbr\u003eMass    850 kg\u003cbr\u003eHeight    2130 mm (standard)\u003cbr\u003e2690 mm (with deflector)\u003cbr\u003e2730 mm (tunnel with external exhaust)\u003cbr\u003e3180 mm (tunnel with absorber)\u003cbr\u003eWidth    800 mm\u003cbr\u003eDepth    1405 mm\u003cbr\u003e1605 mm\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003cbr\u003eProduct certifications    BV Marine\u003cbr\u003eDNV-GL Marine\u003cbr\u003eAmbient air temperature for operation    -5…40 °C\u003cbr\u003eAmbient air temperature for storage    -25…55 °C\u003cbr\u003eHumidity conditions    Average relative humidity over 24 h \u0026lt;= 95 %\u003cbr\u003eAverage relative humidity over 1 month \u0026lt;= 90 %\u003cbr\u003eOperating altitude    \u0026lt;= 1000 m\u003c\/p\u003e\n\u003cp\u003eContractual warranty\u003cbr\u003eWarranty (in months)    18\u003cbr\u003e\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":47677843112036,"sku":null,"price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/3791\/7796\/files\/RNG_60678_main_image_369_4.jpg?v=1768041130"},{"product_id":"primary-air-insulated-switchgear-pix-bus-coupler-functional-unit-12kv-upto-4000a-upto-40ka-3s-width-1000mm","title":"Primary Air Insulated Switchgear, PIX, bus coupler functional unit, 12kV, upto 4000A, upto 40kA 3s, width 1000mm","description":"\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003cbr\u003eMain\u003cbr\u003eMaster range    SeT Series\u003cbr\u003eRange of product    PIX\u003cbr\u003eProduct name    PIX 12\u003cbr\u003eFunctional unit    BC bus coupler cubicle\u003cbr\u003eInsulation technology    Air insulated switchgear\u003cbr\u003eNumber of phases    3\u003cbr\u003eNetwork type    AC\u003cbr\u003eType of installation    Indoor\u003cbr\u003eBusbar system    Single busbar\u003cbr\u003eSwitching device    Vacuum circuit breaker\u003cbr\u003eProduct compatibility    EvoPact HVX\u003cbr\u003eStandards    IEC 62271-200\u003cbr\u003eRated voltage (Ur)    12 kV\u003cbr\u003eRated short-duration power frequency withstand voltage (Ud) \/ Common value    28 kV\u003cbr\u003eRated lightning impulse withstand voltage (Up) \/ Common value    75 kV\u003cbr\u003eRated frequency (fr)    50\/60 Hz\u003cbr\u003eRated continuous current of busbars (Ir)    4000 A\u003cbr\u003eRated continuous current (Ir)    2500 A\u003cbr\u003e3150 A\u003cbr\u003e4000 A\u003cbr\u003eRated short-circuit breaking current (Isc)    40 kA\u003cbr\u003eRated short-circuit making current    100 kA 50 Hz\u003cbr\u003e104 kA 60 Hz\u003cbr\u003eRated short-time withstand current (Ik)    25 kA\u003cbr\u003e31.5 kA\u003cbr\u003e40 kA\u003cbr\u003eRated duration of short-circuit (tk)    3 s\u003cbr\u003eRated peak withstand current (Ip)    100 kA 50 Hz\u003cbr\u003e104 kA 60 Hz\u003cbr\u003eLoss of service continuity category    LSC2B\u003cbr\u003eInternal arc classification    AFLR\u003cbr\u003eRated arc fault current (IA)    40 kA\u003cbr\u003eRated arc fault duration (tA)    1 s\u003cbr\u003eInternal arc gas evacuation    Upwards inside the room\u003cbr\u003eUpwards outside the room\u003cbr\u003ePartition class    PM\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eComplementary\u003c\/strong\u003e\u003cbr\u003eDegrees of protection provided by enclosures (IP code)    IP3X\u003cbr\u003eIP4X\u003cbr\u003eIPX2\u003cbr\u003eIP2X (between compartments)\u003cbr\u003eDegree of protection of enclosure against external mechanical impacts (IK code)    IK07\u003cbr\u003eInstrument transformer    Current transformer\u003cbr\u003eSensor type    TH110 thermal sensor\u003cbr\u003eCL110 environmental sensor\u003cbr\u003ePD100 partial discharges monitoring solution\u003cbr\u003eVoltage presence type    VPIS voltage presence indicating system\u003cbr\u003eVDIS voltage detecting and indicating system\u003cbr\u003eProtection relay    Easergy P3\u003cbr\u003eEasergy P5\u003cbr\u003eEasergy Sepam series 60\u003cbr\u003eEasergy Sepam series 80\u003cbr\u003eArc fault detector    Easergy Vamp 125\u003cbr\u003eMass    1100 kg\u003cbr\u003eHeight    2130 mm (standard)\u003cbr\u003e2690 mm (with deflector)\u003cbr\u003e2730 mm (tunnel with external exhaust)\u003cbr\u003e3180 mm (tunnel with absorber)\u003cbr\u003eWidth    1000 mm\u003cbr\u003eDepth    1405 mm\u003cbr\u003e1605 mm\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003cbr\u003eProduct certifications    BV Marine\u003cbr\u003eDNV-GL Marine\u003cbr\u003eAmbient air temperature for operation    -5…40 °C\u003cbr\u003eAmbient air temperature for storage    -25…55 °C\u003cbr\u003eHumidity conditions    Average relative humidity over 24 h \u0026lt;= 95 %\u003cbr\u003eAverage relative humidity over 1 month \u0026lt;= 90 %\u003cbr\u003eOperating altitude    \u0026lt;= 1000 m\u003c\/p\u003e\n\u003cp\u003eContractual warranty\u003cbr\u003eWarranty (in months)    18\u003cbr\u003e\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":47677863592036,"sku":null,"price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/3791\/7796\/files\/RNG_60678_main_image_369_5.jpg?v=1768041356"},{"product_id":"primary-air-insulated-switchgear-pix-bus-riser-functional-unit-12kv-2000a-upto-40ka-3s-width-800mm","title":"Primary Air Insulated Switchgear, PIX, bus riser functional unit, 12kV, 2000A, upto 40kA 3s, width 800mm","description":"\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003cbr\u003eMain\u003cbr\u003eMaster range    SeT Series\u003cbr\u003eRange of product    PIX\u003cbr\u003eProduct name    PIX 12\u003cbr\u003eFunctional unit    BR bus riser cubicle\u003cbr\u003eInsulation technology    Air insulated switchgear\u003cbr\u003eNumber of phases    3\u003cbr\u003eNetwork type    AC\u003cbr\u003eType of installation    Indoor\u003cbr\u003eBusbar system    Single busbar\u003cbr\u003eSwitching device    Metering device\u003cbr\u003eDisconnecting device\u003cbr\u003eProduct compatibility    EvoPact MTX\u003cbr\u003eEvoPact UTX\u003cbr\u003eStandards    IEC 62271-200\u003cbr\u003eRated voltage (Ur)    12 kV\u003cbr\u003eRated short-duration power frequency withstand voltage (Ud) \/ Common value    28 kV\u003cbr\u003eRated lightning impulse withstand voltage (Up) \/ Common value    75 kV\u003cbr\u003eRated frequency (fr)    50\/60 Hz\u003cbr\u003eRated continuous current of busbars (Ir)    4000 A\u003cbr\u003eRated continuous current (Ir)    1600 A\u003cbr\u003e2000 A\u003cbr\u003eRated short-time withstand current (Ik)    25 kA\u003cbr\u003e31.5 kA\u003cbr\u003e40 kA\u003cbr\u003eRated duration of short-circuit (tk)    3 s\u003cbr\u003eRated peak withstand current (Ip)    100 kA 50 Hz\u003cbr\u003e104 kA 60 Hz\u003cbr\u003eLoss of service continuity category    LSC2B\u003cbr\u003eInternal arc classification    AFLR\u003cbr\u003eRated arc fault current (IA)    40 kA\u003cbr\u003eRated arc fault duration (tA)    1 s\u003cbr\u003eInternal arc gas evacuation    Upwards inside the room\u003cbr\u003eUpwards outside the room\u003cbr\u003ePartition class    PM\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eComplementary\u003c\/strong\u003e\u003cbr\u003eDegrees of protection provided by enclosures (IP code)    IP3X\u003cbr\u003eIP4X\u003cbr\u003eIPX2\u003cbr\u003eIP2X (between compartments)\u003cbr\u003eDegree of protection of enclosure against external mechanical impacts (IK code)    IK07\u003cbr\u003eSensor type    TH110 thermal sensor\u003cbr\u003eCL110 environmental sensor\u003cbr\u003eVoltage presence type    VPIS voltage presence indicating system\u003cbr\u003eVDIS voltage detecting and indicating system\u003cbr\u003eProtection relay    Easergy P3\u003cbr\u003eEasergy P5\u003cbr\u003eEasergy Sepam series 60\u003cbr\u003eEasergy Sepam series 80\u003cbr\u003eArc fault detector    Easergy Vamp 125\u003cbr\u003eMass    850 kg\u003cbr\u003eHeight    2130 mm (standard)\u003cbr\u003e2690 mm (with deflector)\u003cbr\u003e2730 mm (tunnel with external exhaust)\u003cbr\u003e3180 mm (tunnel with absorber)\u003cbr\u003eWidth    800 mm\u003cbr\u003eDepth    1405 mm\u003cbr\u003e1605 mm\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003cbr\u003eProduct certifications    BV Marine\u003cbr\u003eDNV-GL Marine\u003cbr\u003eAmbient air temperature for operation    -5…40 °C\u003cbr\u003eAmbient air temperature for storage    -25…55 °C\u003cbr\u003eHumidity conditions    Average relative humidity over 24 h \u0026lt;= 95 %\u003cbr\u003eAverage relative humidity over 1 month \u0026lt;= 90 %\u003cbr\u003eOperating altitude    \u0026lt;= 1000 m\u003c\/p\u003e\n\u003cp\u003eContractual warranty\u003cbr\u003eWarranty (in months)    18\u003cbr\u003e\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":47677900718180,"sku":null,"price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/3791\/7796\/files\/RNG_60678_main_image_369_6.jpg?v=1768041711"},{"product_id":"primary-air-insulated-switchgear-pix-bus-riser-functional-unit-12kv-upto-4000a-upto-40ka-3s-width-1000mm","title":"Primary Air Insulated Switchgear, PIX, bus riser functional unit, 12kV, upto 4000A, upto 40kA 3s, width 1000mm","description":"\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003cbr\u003eMain\u003cbr\u003eMaster range    SeT Series\u003cbr\u003eRange of product    PIX\u003cbr\u003eProduct name    PIX 12\u003cbr\u003eFunctional unit    BR bus riser cubicle\u003cbr\u003eInsulation technology    Air insulated switchgear\u003cbr\u003eNumber of phases    3\u003cbr\u003eNetwork type    AC\u003cbr\u003eType of installation    Indoor\u003cbr\u003eBusbar system    Single busbar\u003cbr\u003eSwitching device    Metering device\u003cbr\u003eDisconnecting device\u003cbr\u003eProduct compatibility    EvoPact MTX\u003cbr\u003eEvoPact UTX\u003cbr\u003eStandards    IEC 62271-200\u003cbr\u003eRated voltage (Ur)    12 kV\u003cbr\u003eRated short-duration power frequency withstand voltage (Ud) \/ Common value    28 kV\u003cbr\u003eRated lightning impulse withstand voltage (Up) \/ Common value    75 kV\u003cbr\u003eRated frequency (fr)    50\/60 Hz\u003cbr\u003eRated continuous current of busbars (Ir)    4000 A\u003cbr\u003eRated continuous current (Ir)    2500 A\u003cbr\u003e3150 A\u003cbr\u003e4000 A\u003cbr\u003eRated short-time withstand current (Ik)    25 kA\u003cbr\u003e31.5 kA\u003cbr\u003e40 kA\u003cbr\u003eRated duration of short-circuit (tk)    3 s\u003cbr\u003eRated peak withstand current (Ip)    100 kA 50 Hz\u003cbr\u003e104 kA 60 Hz\u003cbr\u003eLoss of service continuity category    LSC2B\u003cbr\u003eInternal arc classification    AFLR\u003cbr\u003eRated arc fault current (IA)    40 kA\u003cbr\u003eRated arc fault duration (tA)    1 s\u003cbr\u003eInternal arc gas evacuation    Upwards inside the room\u003cbr\u003eUpwards outside the room\u003cbr\u003ePartition class    PM\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eComplementary\u003c\/strong\u003e\u003cbr\u003eDegrees of protection provided by enclosures (IP code)    IP3X\u003cbr\u003eIP4X\u003cbr\u003eIPX2\u003cbr\u003eIP2X (between compartments)\u003cbr\u003eDegree of protection of enclosure against external mechanical impacts (IK code)    IK07\u003cbr\u003eSensor type    TH110 thermal sensor\u003cbr\u003eCL110 environmental sensor\u003cbr\u003eVoltage presence type    VPIS voltage presence indicating system\u003cbr\u003eVDIS voltage detecting and indicating system\u003cbr\u003eProtection relay    Easergy P3\u003cbr\u003eEasergy P5\u003cbr\u003eEasergy Sepam series 60\u003cbr\u003eEasergy Sepam series 80\u003cbr\u003eArc fault detector    Easergy Vamp 125\u003cbr\u003eMass    1100 kg\u003cbr\u003eHeight    2130 mm (standard)\u003cbr\u003e2690 mm (with deflector)\u003cbr\u003e2730 mm (tunnel with external exhaust)\u003cbr\u003e3180 mm (tunnel with absorber)\u003cbr\u003eWidth    1000 mm\u003cbr\u003eDepth    1405 mm\u003cbr\u003e1605 mm\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003cbr\u003eProduct certifications    BV Marine\u003cbr\u003eDNV-GL Marine\u003cbr\u003eAmbient air temperature for operation    -5…40 °C\u003cbr\u003eAmbient air temperature for storage    -25…55 °C\u003cbr\u003eHumidity conditions    Average relative humidity over 24 h \u0026lt;= 95 %\u003cbr\u003eAverage relative humidity over 1 month \u0026lt;= 90 %\u003cbr\u003eOperating altitude    \u0026lt;= 1000 m\u003c\/p\u003e\n\u003cp\u003eContractual warranty\u003cbr\u003eWarranty (in months)    18\u003cbr\u003e\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":47677912383588,"sku":null,"price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/3791\/7796\/files\/RNG_60678_main_image_369_7.jpg?v=1768041883"},{"product_id":"primary-air-insulated-switchgear-pix-direct-incomer-functional-unit-12kv-1250a-40ka-width-650mm","title":"Primary Air Insulated Switchgear, PIX, direct incomer functional unit, 12kV, 1250A, 40kA, width 650mm","description":"\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003cbr\u003eMain\u003cbr\u003eMaster range    SeT Series\u003cbr\u003eRange of product    PIX\u003cbr\u003eProduct name    PIX 12\u003cbr\u003eFunctional unit    Direct incomer\u003cbr\u003eInsulation technology    Air insulated switchgear\u003cbr\u003eNumber of phases    3\u003cbr\u003eNetwork type    AC\u003cbr\u003eType of installation    Indoor\u003cbr\u003eBusbar system    Single busbar\u003cbr\u003eSwitching device    Disconnecting device\u003cbr\u003eProduct compatibility    EvoPact UTX\u003cbr\u003eStandards    IEC 62271-200\u003cbr\u003eRated voltage (Ur)    12 kV\u003cbr\u003eRated short-duration power frequency withstand voltage (Ud) \/ Common value    28 kV\u003cbr\u003eRated lightning impulse withstand voltage (Up) \/ Common value    75 kV\u003cbr\u003eRated frequency (fr)    50\/60 Hz\u003cbr\u003eRated continuous current of busbars (Ir)    4000 A\u003cbr\u003eRated continuous current (Ir)    800 A\u003cbr\u003e1250 A\u003cbr\u003eRated short-circuit breaking current (Isc)    40 kA\u003cbr\u003eRated short-time withstand current (Ik)    25 kA\u003cbr\u003e31.5 kA\u003cbr\u003e40 kA\u003cbr\u003eRated duration of short-circuit (tk)    3 s\u003cbr\u003eRated peak withstand current (Ip)    100 kA 50 Hz\u003cbr\u003e104 kA 60 Hz\u003cbr\u003eLoss of service continuity category    LSC2B\u003cbr\u003eInternal arc classification    AFLR\u003cbr\u003eRated arc fault current (IA)    40 kA\u003cbr\u003eRated arc fault duration (tA)    1 s\u003cbr\u003eInternal arc gas evacuation    Upwards inside the room\u003cbr\u003eUpwards outside the room\u003cbr\u003ePartition class    PM\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eComplementary\u003c\/strong\u003e\u003cbr\u003eDegrees of protection provided by enclosures (IP code)    IP3X\u003cbr\u003eIP4X\u003cbr\u003eIPX2\u003cbr\u003eIP2X (between compartments)\u003cbr\u003eDegree of protection of enclosure against external mechanical impacts (IK code)    IK07\u003cbr\u003eInstrument transformer    Current transformer\u003cbr\u003eVoltage transformer\u003cbr\u003eSurge arrester\u003cbr\u003eSensor type    TH110 thermal sensor\u003cbr\u003eCL110 environmental sensor\u003cbr\u003ePD100 partial discharges monitoring solution\u003cbr\u003eVoltage presence type    VPIS voltage presence indicating system\u003cbr\u003eVDIS voltage detecting and indicating system\u003cbr\u003eProtection relay    Easergy P3\u003cbr\u003eEasergy P5\u003cbr\u003eEasergy Sepam series 60\u003cbr\u003eEasergy Sepam series 80\u003cbr\u003eArc fault detector    Easergy Vamp 125\u003cbr\u003eCable type    Single core\u003cbr\u003eThree core\u003cbr\u003eCable cross-section    630 mm²\u003cbr\u003eNumber of cables per phase    Up to 4\u003cbr\u003eMass    750 kg\u003cbr\u003eHeight    2130 mm (standard)\u003cbr\u003e2690 mm (with deflector)\u003cbr\u003e2730 mm (tunnel with external exhaust)\u003cbr\u003e3180 mm (tunnel with absorber)\u003cbr\u003eWidth    650 mm\u003cbr\u003eDepth    1405 mm\u003cbr\u003e1605 mm\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003cbr\u003eProduct certifications    BV Marine\u003cbr\u003eDNV-GL Marine\u003cbr\u003eAmbient air temperature for operation    -5…40 °C\u003cbr\u003eAmbient air temperature for storage    -25…55 °C\u003cbr\u003eHumidity conditions    Average relative humidity over 24 h \u0026lt;= 95 %\u003cbr\u003eAverage relative humidity over 1 month \u0026lt;= 90 %\u003cbr\u003eOperating altitude    \u0026lt;= 1000 m\u003c\/p\u003e\n\u003cp\u003eContractual warranty\u003cbr\u003eWarranty (in months)    18\u003cbr\u003e\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":47677931126884,"sku":null,"price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/3791\/7796\/files\/RNG_60678_main_image_369_8.jpg?v=1768042078"},{"product_id":"primary-air-insulated-switchgear-pix-direct-incomer-functional-unit-12kv-2000a-40ka-width-800mm","title":"Primary Air Insulated Switchgear, PIX, direct incomer functional unit, 12kV, 2000A, 40kA, width 800mm","description":"\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003cbr\u003eMain\u003cbr\u003eMaster range    SeT Series\u003cbr\u003eRange of product    PIX\u003cbr\u003eProduct name    PIX 12\u003cbr\u003eFunctional unit    Direct incomer\u003cbr\u003eInsulation technology    Air insulated switchgear\u003cbr\u003eNumber of phases    3\u003cbr\u003eNetwork type    AC\u003cbr\u003eType of installation    Indoor\u003cbr\u003eBusbar system    Single busbar\u003cbr\u003eSwitching device    Disconnecting device\u003cbr\u003eProduct compatibility    EvoPact UTX\u003cbr\u003eStandards    IEC 62271-200\u003cbr\u003eRated voltage (Ur)    12 kV\u003cbr\u003eRated short-duration power frequency withstand voltage (Ud) \/ Common value    28 kV\u003cbr\u003eRated lightning impulse withstand voltage (Up) \/ Common value    75 kV\u003cbr\u003eRated frequency (fr)    50\/60 Hz\u003cbr\u003eRated continuous current of busbars (Ir)    4000 A\u003cbr\u003eRated continuous current (Ir)    1600 A\u003cbr\u003e2000 A\u003cbr\u003eRated short-circuit breaking current (Isc)    40 kA\u003cbr\u003eRated short-time withstand current (Ik)    25 kA\u003cbr\u003e31.5 kA\u003cbr\u003e40 kA\u003cbr\u003eRated duration of short-circuit (tk)    3 s\u003cbr\u003eRated peak withstand current (Ip)    100 kA 50 Hz\u003cbr\u003e104 kA 60 Hz\u003cbr\u003eLoss of service continuity category    LSC2B\u003cbr\u003eInternal arc classification    AFLR\u003cbr\u003eRated arc fault current (IA)    40 kA\u003cbr\u003eRated arc fault duration (tA)    1 s\u003cbr\u003eInternal arc gas evacuation    Upwards inside the room\u003cbr\u003eUpwards outside the room\u003cbr\u003ePartition class    PM\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eComplementary\u003c\/strong\u003e\u003cbr\u003eDegrees of protection provided by enclosures (IP code)    IP3X\u003cbr\u003eIP4X\u003cbr\u003eIPX2\u003cbr\u003eIP2X (between compartments)\u003cbr\u003eDegree of protection of enclosure against external mechanical impacts (IK code)    IK07\u003cbr\u003eInstrument transformer    Current transformer\u003cbr\u003eVoltage transformer\u003cbr\u003eSurge arrester\u003cbr\u003eSensor type    TH110 thermal sensor\u003cbr\u003eCL110 environmental sensor\u003cbr\u003ePD100 partial discharges monitoring solution\u003cbr\u003eVoltage presence type    VPIS voltage presence indicating system\u003cbr\u003eVDIS voltage detecting and indicating system\u003cbr\u003eProtection relay    Easergy P3\u003cbr\u003eEasergy P5\u003cbr\u003eEasergy Sepam series 60\u003cbr\u003eEasergy Sepam series 80\u003cbr\u003eArc fault detector    Easergy Vamp 125\u003cbr\u003eCable type    Single core\u003cbr\u003eThree core\u003cbr\u003eCable cross-section    630 mm²\u003cbr\u003eNumber of cables per phase    Up to 4\u003cbr\u003eMass    850 kg\u003cbr\u003eHeight    2130 mm (standard)\u003cbr\u003e2690 mm (with deflector)\u003cbr\u003e2730 mm (tunnel with external exhaust)\u003cbr\u003e3180 mm (tunnel with absorber)\u003cbr\u003eWidth    650 mm\u003cbr\u003eDepth    1405 mm\u003cbr\u003e1605 mm\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003cbr\u003eProduct certifications    BV Marine\u003cbr\u003eDNV-GL Marine\u003cbr\u003eAmbient air temperature for operation    -5…40 °C\u003cbr\u003eAmbient air temperature for storage    -25…55 °C\u003cbr\u003eHumidity conditions    Average relative humidity over 24 h \u0026lt;= 95 %\u003cbr\u003eAverage relative humidity over 1 month \u0026lt;= 90 %\u003cbr\u003eOperating altitude    \u0026lt;= 1000 m\u003c\/p\u003e\n\u003cp\u003eContractual warranty\u003cbr\u003eWarranty (in months)    18\u003cbr\u003e\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":47677985194084,"sku":null,"price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/3791\/7796\/files\/RNG_60678_main_image_369_9.jpg?v=1768042244"},{"product_id":"primary-air-insulated-switchgear-pix-direct-incomer-functional-unit-12kv-4000a-40ka-width-1000mm","title":"Primary Air Insulated Switchgear, PIX, direct incomer functional unit, 12kV, 4000A, 40kA, width 1000mm","description":"\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003cbr\u003eMain\u003cbr\u003eMaster range    SeT Series\u003cbr\u003eRange of product    PIX\u003cbr\u003eProduct name    PIX 12\u003cbr\u003eFunctional unit    Direct incomer\u003cbr\u003eInsulation technology    Air insulated switchgear\u003cbr\u003eNumber of phases    3\u003cbr\u003eNetwork type    AC\u003cbr\u003eType of installation    Indoor\u003cbr\u003eBusbar system    Single busbar\u003cbr\u003eSwitching device    Disconnecting device\u003cbr\u003eProduct compatibility    EvoPact UTX\u003cbr\u003eStandards    IEC 62271-200\u003cbr\u003eRated voltage (Ur)    12 kV\u003cbr\u003eRated short-duration power frequency withstand voltage (Ud) \/ Common value    28 kV\u003cbr\u003eRated lightning impulse withstand voltage (Up) \/ Common value    75 kV\u003cbr\u003eRated frequency (fr)    50\/60 Hz\u003cbr\u003eRated continuous current of busbars (Ir)    4000 A\u003cbr\u003eRated continuous current (Ir)    2500 A\u003cbr\u003e3150 A\u003cbr\u003e4000 A\u003cbr\u003eRated short-circuit breaking current (Isc)    40 kA\u003cbr\u003eRated short-time withstand current (Ik)    25 kA\u003cbr\u003e31.5 kA\u003cbr\u003e40 kA\u003cbr\u003eRated duration of short-circuit (tk)    3 s\u003cbr\u003eRated peak withstand current (Ip)    100 kA 50 Hz\u003cbr\u003e104 kA 60 Hz\u003cbr\u003eLoss of service continuity category    LSC2B\u003cbr\u003eInternal arc classification    AFLR\u003cbr\u003eRated arc fault current (IA)    40 kA\u003cbr\u003eRated arc fault duration (tA)    1 s\u003cbr\u003eInternal arc gas evacuation    Upwards inside the room\u003cbr\u003eUpwards outside the room\u003cbr\u003ePartition class    PM\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eComplementary\u003c\/strong\u003e\u003cbr\u003eDegrees of protection provided by enclosures (IP code)    IP3X\u003cbr\u003eIP4X\u003cbr\u003eIPX2\u003cbr\u003eIP2X (between compartments)\u003cbr\u003eDegree of protection of enclosure against external mechanical impacts (IK code)    IK07\u003cbr\u003eInstrument transformer    Current transformer\u003cbr\u003eVoltage transformer\u003cbr\u003eSurge arrester\u003cbr\u003eSensor type    TH110 thermal sensor\u003cbr\u003eCL110 environmental sensor\u003cbr\u003ePD100 partial discharges monitoring solution\u003cbr\u003eVoltage presence type    VPIS voltage presence indicating system\u003cbr\u003eVDIS voltage detecting and indicating system\u003cbr\u003eProtection relay    Easergy P3\u003cbr\u003eEasergy P5\u003cbr\u003eEasergy Sepam series 60\u003cbr\u003eEasergy Sepam series 80\u003cbr\u003eArc fault detector    Easergy Vamp 125\u003cbr\u003eCable type    Single core\u003cbr\u003eThree core\u003cbr\u003eCable cross-section    630 mm²\u003cbr\u003eNumber of cables per phase    Up to 4\u003cbr\u003eMass    1100 kg\u003cbr\u003eHeight    2130 mm (standard)\u003cbr\u003e2690 mm (with deflector)\u003cbr\u003e2730 mm (tunnel with external exhaust)\u003cbr\u003e3180 mm (tunnel with absorber)\u003cbr\u003eWidth    650 mm\u003cbr\u003eDepth    1405 mm\u003cbr\u003e1605 mm\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003cbr\u003eProduct certifications    BV Marine\u003cbr\u003eDNV-GL Marine\u003cbr\u003eAmbient air temperature for operation    -5…40 °C\u003cbr\u003eAmbient air temperature for storage    -25…55 °C\u003cbr\u003eHumidity conditions    Average relative humidity over 24 h \u0026lt;= 95 %\u003cbr\u003eAverage relative humidity over 1 month \u0026lt;= 90 %\u003cbr\u003eOperating altitude    \u0026lt;= 1000 m\u003c\/p\u003e\n\u003cp\u003eContractual warranty\u003cbr\u003eWarranty (in months)    18\u003cbr\u003e\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":47678014226532,"sku":null,"price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/3791\/7796\/files\/RNG_60678_main_image_369_10.jpg?v=1768042387"},{"product_id":"primary-air-insulated-switchgear-mcset-17-5kv-incomer-or-feeder-functional-unit-up-to-12kv-up-to-4000a-50ka-width-570mm","title":"Primary Air Insulated Switchgear, MCSet 17.5kV, incomer or feeder functional unit, up to 12kV, up to 4000A, 50kA, width 570mm","description":"\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003cbr\u003eMain\u003cbr\u003eMaster range    SeT Series\u003cbr\u003eRange of product    MCSeT\u003cbr\u003eProduct name    MCSet 17.5 kV\u003cbr\u003eDevice short name    AD1C\u003cbr\u003eFunctional unit    Incomer\u003cbr\u003eFeeder\u003cbr\u003eProduct or component type    Cubicle\u003cbr\u003eInsulation technology    Air insulated switchgear\u003cbr\u003eNumber of phases    3\u003cbr\u003eNetwork type    AC\u003cbr\u003eType of installation    Indoor\u003cbr\u003eBusbar system    Single busbar\u003cbr\u003eSwitching device    SF6 contactor\u003cbr\u003eVacuum contactor\u003cbr\u003eProduct compatibility    Rollarc\u003cbr\u003eCTV1\u003cbr\u003eStandards    IEC 62271-200\u003cbr\u003eRated voltage (Ur)    12 kV\u003cbr\u003eRated short-duration power frequency withstand voltage (Ud) \/ Common value    28 kV\u003cbr\u003eRated lightning impulse withstand voltage (Up) \/ Common value    75 kV\u003cbr\u003eRated frequency (fr)    50\/60 Hz\u003cbr\u003eRated continuous current of busbars (Ir)    4000 A\u003cbr\u003eRated continuous current (Ir)    400 A contactor only\u003cbr\u003e315 A with fuse at 7.2 kV\u003cbr\u003e200 A with fuse at 12 kV\u003cbr\u003eRated short-circuit breaking current (Isc)    50 kA with fuse\u003cbr\u003eRated short-circuit making current    125 kA 50 Hz\u003cbr\u003e130 kA 60 Hz\u003cbr\u003eRated short-time withstand current (Ik)    50 kA\u003cbr\u003eRated duration of short-circuit (tk)    3 s\u003cbr\u003eRated peak withstand current (Ip)    125 kA 50 Hz\u003cbr\u003e130 kA 60 Hz\u003cbr\u003eLoss of service continuity category    LSC2B\u003cbr\u003eInternal arc classification    AFL\u003cbr\u003eAFLR\u003cbr\u003eRated arc fault current (IA)    50 kA\u003cbr\u003eRated arc fault duration (tA)    1 s\u003cbr\u003eInternal arc gas evacuation    Upwards inside the room\u003cbr\u003eUpwards outside the room\u003cbr\u003ePartition class    PM\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eComplementary\u003c\/strong\u003e\u003cbr\u003eDegrees of protection provided by enclosures (IP code)    IP3X (enclosure)\u003cbr\u003eIP4X (enclosure)\u003cbr\u003eIPX1 (enclosure)\u003cbr\u003eIPX2 (enclosure)\u003cbr\u003eIP2XC (between compartments)\u003cbr\u003eDegree of protection of enclosure against external mechanical impacts (IK code)    IK07\u003cbr\u003eInstrument transformer    Current transformer\u003cbr\u003eSurge arrester\u003cbr\u003eSensor type    TH110 thermal sensor\u003cbr\u003eCL110 environmental sensor\u003cbr\u003ePD100 partial discharges monitoring solution\u003cbr\u003eVoltage presence type    VPIS voltage presence indicating system\u003cbr\u003eVDIS voltage detecting and indicating system\u003cbr\u003eProtection relay    Easergy P3\u003cbr\u003eEasergy P5\u003cbr\u003eEasergy Sepam series 60\u003cbr\u003eEasergy Sepam series 80\u003cbr\u003eArc fault detector    Easergy Vamp 125\u003cbr\u003eCable type    Single core\u003cbr\u003eThree core\u003cbr\u003eCable cross-section    630 mm² single core\u003cbr\u003e240 mm² three core\u003cbr\u003eNumber of cables per phase    Up to 3\u003cbr\u003eMass    850 kg\u003cbr\u003eHeight    2300 mm\u003cbr\u003e2770 mm (tunnel with external exhaust)\u003cbr\u003e2770 mm (tunnel with internal exhaust)\u003cbr\u003e2530 mm (compact tunnel with internal exhaust)\u003cbr\u003eWidth    570 mm\u003cbr\u003eDepth    1550 mm (AFL)\u003cbr\u003e1725 mm (AFLR)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003cbr\u003eAmbient air temperature for operation    -5…40 °C\u003cbr\u003eAmbient air temperature for storage    -25…55 °C\u003cbr\u003eHumidity conditions    Average relative humidity over 24 h \u0026lt;= 95 %\u003cbr\u003eAverage relative humidity over 1 month \u0026lt;= 90 %\u003cbr\u003eOperating altitude    \u0026lt;= 1000 m\u003cbr\u003e\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":47678098047076,"sku":null,"price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/3791\/7796\/files\/PE57466_4000x4000_369.jpg?v=1768042847"},{"product_id":"primary-air-insulated-switchgear-mcset-17-5kv-incomer-or-feeder-functional-unit-up-to-12kv-up-to-4000a-31-5ka-width-570mm","title":"Primary Air Insulated Switchgear, MCSet 17.5kV, incomer or feeder functional unit, up to 12kV, up to 4000A, 31.5kA, width 570mm","description":"\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003cbr\u003eMain\u003cbr\u003eMaster range    SeT Series\u003cbr\u003eRange of product    MCSeT\u003cbr\u003eProduct name    MCSet 17.5 kV\u003cbr\u003eDevice short name    AD1\u003cbr\u003eFunctional unit    Incomer\u003cbr\u003eFeeder\u003cbr\u003eProduct or component type    Cubicle\u003cbr\u003eInsulation technology    Air insulated switchgear\u003cbr\u003eNumber of phases    3\u003cbr\u003eNetwork type    AC\u003cbr\u003eType of installation    Indoor\u003cbr\u003eBusbar system    Single busbar\u003cbr\u003eSwitching device    Vacuum circuit breaker\u003cbr\u003eProduct compatibility    EasyPact EXE\u003cbr\u003eStandards    IEC 62271-200\u003cbr\u003eRated voltage (Ur)    12 kV\u003cbr\u003eRated short-duration power frequency withstand voltage (Ud) \/ Common value    28 kV\u003cbr\u003eRated lightning impulse withstand voltage (Up) \/ Common value    75 kV\u003cbr\u003eRated frequency (fr)    50\/60 Hz\u003cbr\u003eRated continuous current of busbars (Ir)    4000 A\u003cbr\u003eRated continuous current (Ir)    630 A\u003cbr\u003e1250 A\u003cbr\u003eRated short-circuit breaking current (Isc)    31.5 kA\u003cbr\u003eRated short-circuit making current    79 kA 50 Hz\u003cbr\u003e82 kA 60 Hz\u003cbr\u003eRated short-time withstand current (Ik)    31.5 kA\u003cbr\u003eRated duration of short-circuit (tk)    3 s\u003cbr\u003eRated peak withstand current (Ip)    79 kA 50 Hz\u003cbr\u003e82 kA 60 Hz\u003cbr\u003eLoss of service continuity category    LSC2B\u003cbr\u003eInternal arc classification    AFL\u003cbr\u003eAFLR\u003cbr\u003eRated arc fault current (IA)    31.5 kA\u003cbr\u003eRated arc fault duration (tA)    1 s\u003cbr\u003eInternal arc gas evacuation    Upwards inside the room\u003cbr\u003eUpwards outside the room\u003cbr\u003ePartition class    PM\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eComplementary\u003c\/strong\u003e\u003cbr\u003eDegrees of protection provided by enclosures (IP code)    IP3X (enclosure)\u003cbr\u003eIP4X (enclosure)\u003cbr\u003eIPX1 (enclosure)\u003cbr\u003eIPX2 (enclosure)\u003cbr\u003eIP2XC (between compartments)\u003cbr\u003eDegree of protection of enclosure against external mechanical impacts (IK code)    IK07\u003cbr\u003eInstrument transformer    Current transformer\u003cbr\u003eVoltage transformer\u003cbr\u003eSurge arrester\u003cbr\u003eSensor type    TH110 thermal sensor\u003cbr\u003eCL110 environmental sensor\u003cbr\u003ePD100 partial discharges monitoring solution\u003cbr\u003eVoltage presence type    VPIS voltage presence indicating system\u003cbr\u003eVDIS voltage detecting and indicating system\u003cbr\u003eProtection relay    Easergy P3\u003cbr\u003eEasergy P5\u003cbr\u003eEasergy Sepam series 60\u003cbr\u003eEasergy Sepam series 80\u003cbr\u003eArc fault detector    Easergy Vamp 125\u003cbr\u003eCable type    Single core\u003cbr\u003eThree core\u003cbr\u003eCable cross-section    630 mm² single core\u003cbr\u003e240 mm² three core\u003cbr\u003eNumber of cables per phase    Up to 3\u003cbr\u003eMass    850 kg\u003cbr\u003eHeight    2300 mm\u003cbr\u003e2530 mm (compact tunnel with internal exhaust)\u003cbr\u003e2770 mm (tunnel with external exhaust)\u003cbr\u003e2770 mm (tunnel with internal exhaust)\u003cbr\u003eWidth    570 mm\u003cbr\u003eDepth    1550 mm (AFL)\u003cbr\u003e1725 mm (AFLR)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003cbr\u003eProduct certifications    Bureau Veritas (BV) Marine\u003cbr\u003eDNV Marine\u003cbr\u003eAmerican Bureau of Shipping (ABS) Marine\u003cbr\u003eLloyd’s Register (LR) Marine\u003cbr\u003eAmbient air temperature for operation    -5…40 °C\u003cbr\u003eAmbient air temperature for storage    -25…55 °C\u003cbr\u003eHumidity conditions    Average relative humidity over 24 h \u0026lt;= 95 %\u003cbr\u003eAverage relative humidity over 1 month \u0026lt;= 90 %\u003cbr\u003eOperating altitude    \u0026lt;= 1000 m\u003cbr\u003e\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":47678139826276,"sku":null,"price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/3791\/7796\/files\/MCSet123productimage_369.jpg?v=1768043036"},{"product_id":"primary-air-insulated-switchgear-mcset-17-5kv-incomer-or-feeder-functional-unit-up-to-17-5kv-up-to-4000a-40ka-width-700mm","title":"Primary Air Insulated Switchgear, MCSet 17.5kV, incomer or feeder functional unit, up to 17.5kV, up to 4000A, 40kA, width 700mm","description":"\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003cbr\u003eMain\u003cbr\u003eMaster range    SeT Series\u003cbr\u003eRange of product    MCSeT\u003cbr\u003eProduct name    MCSet 17.5 kV\u003cbr\u003eDevice short name    AD2\u003cbr\u003eFunctional unit    Incomer\u003cbr\u003eFeeder\u003cbr\u003eProduct or component type    Cubicle\u003cbr\u003eInsulation technology    Air insulated switchgear\u003cbr\u003eNumber of phases    3\u003cbr\u003eNetwork type    AC\u003cbr\u003eType of installation    Indoor\u003cbr\u003eBusbar system    Single busbar\u003cbr\u003eSwitching device    Vacuum circuit breaker\u003cbr\u003eProduct compatibility    EasyPact EXE\u003cbr\u003eStandards    IEC 62271-200\u003cbr\u003eRated voltage (Ur)    17.5 kV\u003cbr\u003eRated short-duration power frequency withstand voltage (Ud) \/ Common value    38 kV\u003cbr\u003eRated lightning impulse withstand voltage (Up) \/ Common value    95 kV\u003cbr\u003eRated frequency (fr)    50\/60 Hz\u003cbr\u003eRated continuous current of busbars (Ir)    4000 A\u003cbr\u003eRated continuous current (Ir)    1250 A\u003cbr\u003eRated short-circuit breaking current (Isc)    40 kA\u003cbr\u003eRated short-circuit making current    100 kA 50 Hz\u003cbr\u003e104 kA 60 Hz\u003cbr\u003eRated short-time withstand current (Ik)    40 kA\u003cbr\u003eRated duration of short-circuit (tk)    3 s\u003cbr\u003eRated peak withstand current (Ip)    100 kA 50 Hz\u003cbr\u003e104 kA 60 Hz\u003cbr\u003eLoss of service continuity category    LSC2B\u003cbr\u003eInternal arc classification    AFL\u003cbr\u003eAFLR\u003cbr\u003eRated arc fault current (IA)    40 kA\u003cbr\u003eRated arc fault duration (tA)    1 s\u003cbr\u003eInternal arc gas evacuation    Upwards inside the room\u003cbr\u003eUpwards outside the room\u003cbr\u003ePartition class    PM\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eComplementary\u003c\/strong\u003e\u003cbr\u003eDegrees of protection provided by enclosures (IP code)    IP3X (enclosure)\u003cbr\u003eIP4X (enclosure)\u003cbr\u003eIPX1 (enclosure)\u003cbr\u003eIPX2 (enclosure)\u003cbr\u003eIP2XC (between compartments)\u003cbr\u003eDegree of protection of enclosure against external mechanical impacts (IK code)    IK07\u003cbr\u003eInstrument transformer    Current transformer\u003cbr\u003eVoltage transformer\u003cbr\u003eSurge arrester\u003cbr\u003eSensor type    TH110 thermal sensor\u003cbr\u003eCL110 environmental sensor\u003cbr\u003ePD100 partial discharges monitoring solution\u003cbr\u003eVoltage presence type    VPIS voltage presence indicating system\u003cbr\u003eVDIS voltage detecting and indicating system\u003cbr\u003eProtection relay    Easergy P3\u003cbr\u003eEasergy P5\u003cbr\u003eEasergy Sepam series 60\u003cbr\u003eEasergy Sepam series 80\u003cbr\u003eArc fault detector    Easergy Vamp 125\u003cbr\u003eCable type    Single core\u003cbr\u003eThree core\u003cbr\u003eCable cross-section    630 mm² single core\u003cbr\u003e240 mm² three core\u003cbr\u003eNumber of cables per phase    Up to 4\u003cbr\u003eMass    1000 kg\u003cbr\u003eHeight    2300 mm\u003cbr\u003e2530 mm (compact tunnel with internal exhaust)\u003cbr\u003e2770 mm (tunnel with external exhaust)\u003cbr\u003e2770 mm (tunnel with internal exhaust)\u003cbr\u003eWidth    700 mm\u003cbr\u003eDepth    1550 mm (AFL)\u003cbr\u003e1725 mm (AFLR)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003cbr\u003eProduct certifications    Bureau Veritas (BV) Marine\u003cbr\u003eDNV Marine\u003cbr\u003eAmerican Bureau of Shipping (ABS) Marine\u003cbr\u003eLloyd’s Register (LR) Marine\u003cbr\u003eAmbient air temperature for operation    -5…40 °C\u003cbr\u003eAmbient air temperature for storage    -25…55 °C\u003cbr\u003eHumidity conditions    Average relative humidity over 24 h \u0026lt;= 95 %\u003cbr\u003eAverage relative humidity over 1 month \u0026lt;= 90 %\u003cbr\u003eOperating altitude    \u0026lt;= 1000 m\u003c\/p\u003e\n\u003cp\u003eContractual warranty\u003cbr\u003eWarranty (in months)    12\u003cbr\u003e\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":47678258118756,"sku":null,"price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/3791\/7796\/files\/MCSet123productimage_369_1.jpg?v=1768044931"},{"product_id":"primary-air-insulated-switchgear-mcset-17-5kv-incomer-or-feeder-functional-unit-up-to-17-5kv-up-to-4000a-50ka-width-900mm","title":"Primary Air Insulated Switchgear, MCSet 17.5kV, incomer or feeder functional unit, up to 17.5kV, up to 4000A, 50kA, width 900mm","description":"\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003cbr\u003eMain\u003cbr\u003eMaster range    SeT Series\u003cbr\u003eRange of product    MCSeT\u003cbr\u003eProduct name    MCSet 17.5 kV\u003cbr\u003eDevice short name    AD3\u003cbr\u003eFunctional unit    Incomer\u003cbr\u003eFeeder\u003cbr\u003eProduct or component type    Cubicle\u003cbr\u003eInsulation technology    Air insulated switchgear\u003cbr\u003eNumber of phases    3\u003cbr\u003eNetwork type    AC\u003cbr\u003eType of installation    Indoor\u003cbr\u003eBusbar system    Single busbar\u003cbr\u003eSwitching device    Vacuum circuit breaker\u003cbr\u003eProduct compatibility    EasyPact EXE\u003cbr\u003eStandards    IEC 62271-200\u003cbr\u003eRated voltage (Ur)    17.5 kV\u003cbr\u003eRated short-duration power frequency withstand voltage (Ud) \/ Common value    38 kV\u003cbr\u003eRated lightning impulse withstand voltage (Up) \/ Common value    95 kV\u003cbr\u003eRated frequency (fr)    50\/60 Hz\u003cbr\u003eRated continuous current of busbars (Ir)    4000 A\u003cbr\u003eRated continuous current (Ir)    1250 A\u003cbr\u003e2500 A\u003cbr\u003e3150 A\u003cbr\u003e4000 A\u003cbr\u003eRated short-circuit breaking current (Isc)    50 kA\u003cbr\u003eRated short-circuit making current    125 kA 50 Hz\u003cbr\u003e130 kA 60 Hz\u003cbr\u003eRated short-time withstand current (Ik)    50 kA\u003cbr\u003eRated duration of short-circuit (tk)    3 s\u003cbr\u003eRated peak withstand current (Ip)    125 kA 50 Hz\u003cbr\u003e130 kA 60 Hz\u003cbr\u003eLoss of service continuity category    LSC2B\u003cbr\u003eInternal arc classification    AFL\u003cbr\u003eAFLR\u003cbr\u003eRated arc fault current (IA)    50 kA\u003cbr\u003eRated arc fault duration (tA)    1 s\u003cbr\u003eInternal arc gas evacuation    Upwards inside the room\u003cbr\u003eUpwards outside the room\u003cbr\u003ePartition class    PM\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eComplementary\u003c\/strong\u003e\u003cbr\u003eDegrees of protection provided by enclosures (IP code)    IP3X (enclosure)\u003cbr\u003eIP4X (enclosure)\u003cbr\u003eIPX1 (enclosure)\u003cbr\u003eIPX2 (enclosure)\u003cbr\u003eIP2XC (between compartments)\u003cbr\u003eDegree of protection of enclosure against external mechanical impacts (IK code)    IK07\u003cbr\u003eInstrument transformer    Current transformer\u003cbr\u003eVoltage transformer\u003cbr\u003eSurge arrester\u003cbr\u003eSensor type    TH110 thermal sensor\u003cbr\u003eCL110 environmental sensor\u003cbr\u003ePD100 partial discharges monitoring solution\u003cbr\u003eVoltage presence type    VPIS voltage presence indicating system\u003cbr\u003eVDIS voltage detecting and indicating system\u003cbr\u003eProtection relay    Easergy P3\u003cbr\u003eEasergy P5\u003cbr\u003eEasergy Sepam series 60\u003cbr\u003eEasergy Sepam series 80\u003cbr\u003eArc fault detector    Easergy Vamp 125\u003cbr\u003eCable type    Single core\u003cbr\u003eThree core\u003cbr\u003eCable cross-section    630 mm² single core\u003cbr\u003e240 mm² three core\u003cbr\u003eNumber of cables per phase    Up to 4\u003cbr\u003eMass    1760 kg\u003cbr\u003eHeight    2300 mm\u003cbr\u003e2530 mm (compact tunnel with internal exhaust)\u003cbr\u003e2770 mm (tunnel with external exhaust)\u003cbr\u003e2770 mm (tunnel with internal exhaust)\u003cbr\u003eWidth    900 mm\u003cbr\u003eDepth    1550 mm (AFL)\u003cbr\u003e1725 mm (AFLR)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003cbr\u003eProduct certifications    Bureau Veritas (BV) Marine\u003cbr\u003eDNV Marine\u003cbr\u003eAmerican Bureau of Shipping (ABS) Marine\u003cbr\u003eLloyd’s Register (LR) Marine\u003cbr\u003eAmbient air temperature for operation    -5…40 °C\u003cbr\u003eAmbient air temperature for storage    -25…55 °C\u003cbr\u003eHumidity conditions    Average relative humidity over 24 h \u0026lt;= 95 %\u003cbr\u003eAverage relative humidity over 1 month \u0026lt;= 90 %\u003cbr\u003eOperating altitude    \u0026lt;= 1000 m\u003cbr\u003e\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":47678274306148,"sku":null,"price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/3791\/7796\/files\/MCSet123productimage_369_2.jpg?v=1768045197"},{"product_id":"primary-air-insulated-switchgear-mcset-17-5kv-line-up-bus-sectioning-functional-unit-up-to-12kv-up-to-4000a-31-5ka-width-570mm","title":"Primary Air Insulated Switchgear, MCSet 17.5kV, line up bus sectioning functional unit, up to 12kV, up to 4000A, 31.5kA, width 570mm","description":"\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003cbr\u003eMain\u003cbr\u003eMaster range    SeT Series\u003cbr\u003eRange of product    MCSeT\u003cbr\u003eProduct name    MCSet 17.5 kV\u003cbr\u003eDevice short name    CL1\u003cbr\u003eFunctional unit    Line up bus sectioning\u003cbr\u003eProduct or component type    Cubicle\u003cbr\u003eInsulation technology    Air insulated switchgear\u003cbr\u003eNumber of phases    3\u003cbr\u003eNetwork type    AC\u003cbr\u003eType of installation    Indoor\u003cbr\u003eBusbar system    Single busbar\u003cbr\u003eSwitching device    Vacuum circuit breaker\u003cbr\u003eProduct compatibility    EasyPact EXE\u003cbr\u003eStandards    IEC 62271-200\u003cbr\u003eRated voltage (Ur)    12 kV\u003cbr\u003eRated short-duration power frequency withstand voltage (Ud) \/ Common value    28 kV\u003cbr\u003eRated lightning impulse withstand voltage (Up) \/ Common value    75 kV\u003cbr\u003eRated frequency (fr)    50\/60 Hz\u003cbr\u003eRated continuous current of busbars (Ir)    4000 A\u003cbr\u003eRated continuous current (Ir)    630 A\u003cbr\u003e1250 A\u003cbr\u003eRated short-circuit breaking current (Isc)    31.5 kA\u003cbr\u003eRated short-circuit making current    79 kA 50 Hz\u003cbr\u003e82 kA 60 Hz\u003cbr\u003eRated short-time withstand current (Ik)    31.5 kA\u003cbr\u003eRated duration of short-circuit (tk)    3 s\u003cbr\u003eRated peak withstand current (Ip)    79 kA 50 Hz\u003cbr\u003e82 kA 60 Hz\u003cbr\u003eLoss of service continuity category    LSC2B\u003cbr\u003eInternal arc classification    AFL\u003cbr\u003eAFLR\u003cbr\u003eRated arc fault current (IA)    31.5 kA\u003cbr\u003eRated arc fault duration (tA)    1 s\u003cbr\u003eInternal arc gas evacuation    Upwards inside the room\u003cbr\u003eUpwards outside the room\u003cbr\u003ePartition class    PM\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eComplementary\u003c\/strong\u003e\u003cbr\u003eDegrees of protection provided by enclosures (IP code)    IP3X (enclosure)\u003cbr\u003eIP4X (enclosure)\u003cbr\u003eIPX1 (enclosure)\u003cbr\u003eIPX2 (enclosure)\u003cbr\u003eIP2XC (between compartments)\u003cbr\u003eDegree of protection of enclosure against external mechanical impacts (IK code)    IK07\u003cbr\u003eInstrument transformer    Current transformer\u003cbr\u003eVoltage transformer\u003cbr\u003eSurge arrester\u003cbr\u003eSensor type    TH110 thermal sensor\u003cbr\u003eCL110 environmental sensor\u003cbr\u003ePD100 partial discharges monitoring solution\u003cbr\u003eVoltage presence type    VPIS voltage presence indicating system\u003cbr\u003eVDIS voltage detecting and indicating system\u003cbr\u003eProtection relay    Easergy P3\u003cbr\u003eEasergy P5\u003cbr\u003eEasergy Sepam series 60\u003cbr\u003eEasergy Sepam series 80\u003cbr\u003eArc fault detector    Easergy Vamp 125\u003cbr\u003eMass    650 kg\u003cbr\u003eHeight    2300 mm\u003cbr\u003e2530 mm (compact tunnel with internal exhaust)\u003cbr\u003e2770 mm (tunnel with external exhaust)\u003cbr\u003e2770 mm (tunnel with internal exhaust)\u003cbr\u003eWidth    570 mm\u003cbr\u003eDepth    1550 mm (AFL)\u003cbr\u003e1725 mm (AFLR)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003cbr\u003eProduct certifications    Bureau Veritas (BV) Marine\u003cbr\u003eDNV Marine\u003cbr\u003eAmerican Bureau of Shipping (ABS) Marine\u003cbr\u003eLloyd’s Register (LR) Marine\u003cbr\u003eAmbient air temperature for operation    -5…40 °C\u003cbr\u003eAmbient air temperature for storage    -25…55 °C\u003cbr\u003eHumidity conditions    Average relative humidity over 24 h \u0026lt;= 95 %\u003cbr\u003eAverage relative humidity over 1 month \u0026lt;= 90 %\u003cbr\u003eOperating altitude    \u0026lt;= 1000 m\u003cbr\u003e\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":47678291869796,"sku":null,"price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/3791\/7796\/files\/MCSet123productimage_369_3.jpg?v=1768045397"},{"product_id":"primary-air-insulated-switchgear-mcset-17-5kv-line-up-bus-sectioning-functional-unit-up-to-17-5kv-up-to-4000a-40ka-width-700mm","title":"Primary Air Insulated Switchgear, MCSet 17.5kV, line up bus sectioning functional unit, up to 17.5kV, up to 4000A, 40kA, width 700mm","description":"\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003cbr\u003eMain\u003cbr\u003eMaster range    SeT Series\u003cbr\u003eRange of product    MCSeT\u003cbr\u003eProduct name    MCSet 17.5 kV\u003cbr\u003eDevice short name    CL2\u003cbr\u003eFunctional unit    Line up bus sectioning\u003cbr\u003eProduct or component type    Cubicle\u003cbr\u003eInsulation technology    Air insulated switchgear\u003cbr\u003eNumber of phases    3\u003cbr\u003eNetwork type    AC\u003cbr\u003eType of installation    Indoor\u003cbr\u003eBusbar system    Single busbar\u003cbr\u003eSwitching device    Vacuum circuit breaker\u003cbr\u003eProduct compatibility    EasyPact EXE\u003cbr\u003eStandards    IEC 62271-200\u003cbr\u003eRated voltage (Ur)    17.5 kV\u003cbr\u003eRated short-duration power frequency withstand voltage (Ud) \/ Common value    38 kV\u003cbr\u003eRated lightning impulse withstand voltage (Up) \/ Common value    95 kV\u003cbr\u003eRated frequency (fr)    50\/60 Hz\u003cbr\u003eRated continuous current of busbars (Ir)    4000 A\u003cbr\u003eRated continuous current (Ir)    1250 A\u003cbr\u003eRated short-circuit breaking current (Isc)    40 kA\u003cbr\u003eRated short-circuit making current    100 kA 50 Hz\u003cbr\u003e104 kA 60 Hz\u003cbr\u003eRated short-time withstand current (Ik)    40 kA\u003cbr\u003eRated duration of short-circuit (tk)    3 s\u003cbr\u003eRated peak withstand current (Ip)    100 kA 50 Hz\u003cbr\u003e104 kA 60 Hz\u003cbr\u003eLoss of service continuity category    LSC2B\u003cbr\u003eInternal arc classification    AFL\u003cbr\u003eAFLR\u003cbr\u003eRated arc fault current (IA)    40 kA\u003cbr\u003eRated arc fault duration (tA)    1 s\u003cbr\u003eInternal arc gas evacuation    Upwards inside the room\u003cbr\u003eUpwards outside the room\u003cbr\u003ePartition class    PM\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eComplementary\u003c\/strong\u003e\u003cbr\u003eDegrees of protection provided by enclosures (IP code)    IP3X (enclosure)\u003cbr\u003eIP4X (enclosure)\u003cbr\u003eIPX1 (enclosure)\u003cbr\u003eIPX2 (enclosure)\u003cbr\u003eIP2XC (between compartments)\u003cbr\u003eDegree of protection of enclosure against external mechanical impacts (IK code)    IK07\u003cbr\u003eInstrument transformer    Current transformer\u003cbr\u003eVoltage transformer\u003cbr\u003eSurge arrester\u003cbr\u003eSensor type    TH110 thermal sensor\u003cbr\u003eCL110 environmental sensor\u003cbr\u003ePD100 partial discharges monitoring solution\u003cbr\u003eVoltage presence type    VPIS voltage presence indicating system\u003cbr\u003eVDIS voltage detecting and indicating system\u003cbr\u003eProtection relay    Easergy P3\u003cbr\u003eEasergy P5\u003cbr\u003eEasergy Sepam series 60\u003cbr\u003eEasergy Sepam series 80\u003cbr\u003eArc fault detector    Easergy Vamp 125\u003cbr\u003eMass    750 kg\u003cbr\u003eHeight    2300 mm\u003cbr\u003e2530 mm (compact tunnel with internal exhaust)\u003cbr\u003e2770 mm (tunnel with external exhaust)\u003cbr\u003e2770 mm (tunnel with internal exhaust)\u003cbr\u003eWidth    700 mm\u003cbr\u003eDepth    1550 mm (AFL)\u003cbr\u003e1725 mm (AFLR)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003cbr\u003eProduct certifications    Bureau Veritas (BV) Marine\u003cbr\u003eDNV Marine\u003cbr\u003eAmerican Bureau of Shipping (ABS) Marine\u003cbr\u003eLloyd’s Register (LR) Marine\u003cbr\u003eAmbient air temperature for operation    -5…40 °C\u003cbr\u003eAmbient air temperature for storage    -25…55 °C\u003cbr\u003eHumidity conditions    Average relative humidity over 24 h \u0026lt;= 95 %\u003cbr\u003eAverage relative humidity over 1 month \u0026lt;= 90 %\u003cbr\u003eOperating altitude    \u0026lt;= 1000 m\u003cbr\u003e\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":47678307139684,"sku":null,"price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/3791\/7796\/files\/MCSet123productimage_369_4.jpg?v=1768045674"},{"product_id":"primary-air-insulated-switchgear-mcset-17-5kv-line-up-bus-sectioning-functional-unit-up-to-17-5kv-up-to-4000a-50ka-width-900mm","title":"Primary Air Insulated Switchgear, MCSet 17.5kV, line up bus sectioning functional unit, up to 17.5kV, up to 4000A, 50kA, width 900mm","description":"\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003cbr\u003eMain\u003cbr\u003eMaster range    SeT Series\u003cbr\u003eRange of product    MCSeT\u003cbr\u003eProduct name    MCSet 17.5 kV\u003cbr\u003eDevice short name    CL3\u003cbr\u003eFunctional unit    Line up bus sectioning\u003cbr\u003eProduct or component type    Cubicle\u003cbr\u003eInsulation technology    Air insulated switchgear\u003cbr\u003eNumber of phases    3\u003cbr\u003eNetwork type    AC\u003cbr\u003eType of installation    Indoor\u003cbr\u003eBusbar system    Single busbar\u003cbr\u003eSwitching device    Vacuum circuit breaker\u003cbr\u003eProduct compatibility    EasyPact EXE\u003cbr\u003eStandards    IEC 62271-200\u003cbr\u003eRated voltage (Ur)    17.5 kV\u003cbr\u003eRated short-duration power frequency withstand voltage (Ud) \/ Common value    38 kV\u003cbr\u003eRated lightning impulse withstand voltage (Up) \/ Common value    95 kV\u003cbr\u003eRated frequency (fr)    50\/60 Hz\u003cbr\u003eRated continuous current of busbars (Ir)    4000 A\u003cbr\u003eRated continuous current (Ir)    1250 A\u003cbr\u003e2500 A\u003cbr\u003e3150 A\u003cbr\u003e4000 A\u003cbr\u003eRated short-circuit breaking current (Isc)    50 kA\u003cbr\u003eRated short-circuit making current    125 kA 50 Hz\u003cbr\u003e130 kA 60 Hz\u003cbr\u003eRated short-time withstand current (Ik)    50 kA\u003cbr\u003eRated duration of short-circuit (tk)    3 s\u003cbr\u003eRated peak withstand current (Ip)    125 kA 50 Hz\u003cbr\u003e130 kA 60 Hz\u003cbr\u003eLoss of service continuity category    LSC2B\u003cbr\u003eInternal arc classification    AFL\u003cbr\u003eAFLR\u003cbr\u003eRated arc fault current (IA)    50 kA\u003cbr\u003eRated arc fault duration (tA)    1 s\u003cbr\u003eInternal arc gas evacuation    Upwards inside the room\u003cbr\u003eUpwards outside the room\u003cbr\u003ePartition class    PM\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eComplementary\u003c\/strong\u003e\u003cbr\u003eDegrees of protection provided by enclosures (IP code)    IP3X (enclosure)\u003cbr\u003eIP4X (enclosure)\u003cbr\u003eIPX1 (enclosure)\u003cbr\u003eIPX2 (enclosure)\u003cbr\u003eIP2XC (between compartments)\u003cbr\u003eDegree of protection of enclosure against external mechanical impacts (IK code)    IK07\u003cbr\u003eInstrument transformer    Current transformer\u003cbr\u003eVoltage transformer\u003cbr\u003eSurge arrester\u003cbr\u003eSensor type    TH110 thermal sensor\u003cbr\u003eCL110 environmental sensor\u003cbr\u003ePD100 partial discharges monitoring solution\u003cbr\u003eVoltage presence type    VPIS voltage presence indicating system\u003cbr\u003eVDIS voltage detecting and indicating system\u003cbr\u003eProtection relay    Easergy P3\u003cbr\u003eEasergy P5\u003cbr\u003eEasergy Sepam series 60\u003cbr\u003eEasergy Sepam series 80\u003cbr\u003eArc fault detector    Easergy Vamp 125\u003cbr\u003eMass    1310 kg\u003cbr\u003eHeight    2300 mm\u003cbr\u003e2530 mm (compact tunnel with internal exhaust)\u003cbr\u003e2770 mm (tunnel with external exhaust)\u003cbr\u003e2770 mm (tunnel with internal exhaust)\u003cbr\u003eWidth    900 mm\u003cbr\u003eDepth    1550 mm (AFL)\u003cbr\u003e1725 mm (AFLR)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003cbr\u003eProduct certifications    Bureau Veritas (BV) Marine\u003cbr\u003eDNV Marine\u003cbr\u003eAmerican Bureau of Shipping (ABS) Marine\u003cbr\u003eLloyd’s Register (LR) Marine\u003cbr\u003eAmbient air temperature for operation    -5…40 °C\u003cbr\u003eAmbient air temperature for storage    -25…55 °C\u003cbr\u003eHumidity conditions    Average relative humidity over 24 h \u0026lt;= 95 %\u003cbr\u003eAverage relative humidity over 1 month \u0026lt;= 90 %\u003cbr\u003eOperating altitude    \u0026lt;= 1000 m\u003cbr\u003e\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":47678325293156,"sku":null,"price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/3791\/7796\/files\/PE57466_4000x4000_369_1.jpg?v=1768045888"}],"url":"https:\/\/www.jublipower.com\/collections\/primary-air-insulated-switchgear.oembed?page=2","provider":"Jublipower","version":"1.0","type":"link"}